Unable to compare with previous version: Unable to find version history at http://fhir.kisumuhealth.co.ke (Problem #1 with package-list.json at http://fhir.kisumuhealth.co.ke: Not Found)
IPA Comparison:
n/a
IPS Comparison:
n/a
Validation Flags:
On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Unable to find ImplementationGuide.definition.resource.description for the resource Consent/ConsentDeclinedExample01. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Consent/ConsentGrantedExample01. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/KCHIPANCVitalsExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource MedicationStatement/KCHIPMedicationStatementExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/KCHIPDangerSignsExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/KCHIPLabResultsExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/KCHIPLabourObservationExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Observation/KCHIPPregnancyContextExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource Condition/KCHIPDiagnosisExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
warning
Unable to find ImplementationGuide.definition.resource.description for the resource ServiceRequest/KCHIPReferralExample. Descriptions are strongly encouraged if they cannot be inferred from the resource to allow proper population of the artifact list.
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
The link 'http://terminology.hl7.org/ValueSet/consentcategorycodes' for "http://terminology.hl7.org/ValueSet/consentcategorycodes" cannot be resolvedHTML_LINK_CHECK_FAILED
1
warning
The HTML fragment 'ip-statements.xhtml' is not included anywhere in the produced implementation guide
2
warning
An HTML fragment from the set [cross-version-analysis.xhtml, cross-version-analysis-inline.xhtml] is not included anywhere in the produced implementation guide
3
warning
An HTML fragment from the set [dependency-table.xhtml, dependency-table-short.xhtml, dependency-table-nontech.xhtml] is not included anywhere in the produced implementation guide
4
warning
The HTML fragment 'globals-table.xhtml' is not included anywhere in the produced implementation guide
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-MNCHCodes.json - the canonical URL (http://fhir.kisumuhealth.co.ke/CodeSystem/MNCHCodes) does not match the URL (http://fhir.health.go.ke/mnch/CodeSystem/MNCHCodes). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
fsh-generated/resources/CodeSystem-MNCHCodes
error
URL Mismatch http://fhir.kisumuhealth.co.ke/CodeSystem/MNCHCodes vs http://fhir.health.go.ke/mnch/CodeSystem/MNCHCodes
Constraint failed: ppc-1: 'Either a Policy or PolicyRule (policy.exists() or policyRule.exists())' (defined in http://hl7.org/fhir/StructureDefinition/Consent)http://hl7.org/fhir/StructureDefinition/Consent#ppc-1
Constraint failed: ppc-1: 'Either a Policy or PolicyRule (policy.exists() or policyRule.exists())' (defined in http://hl7.org/fhir/StructureDefinition/Consent)http://hl7.org/fhir/StructureDefinition/Consent#ppc-1
A definition for CodeSystem 'http://fhir.kisumuhealth.co.ke/CodeSystem/EncounterServiceType' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
Wrong Display Name 'Amoxicillin 500mg Capsule' for http://www.nlm.nih.gov/research/umls/rxnorm#1049630. Valid display is one of 3 choices: 'diphenhydramine hydrochloride 25 MG Oral Tablet' (en-US), 'diphenhydrAMINE hydrochloride 25 MG Oral Tablet' (en-US) or 'diphenhydrAMINE HCl 25 MG Oral Tablet' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://www.nlm.nih.gov/research/umls/rxnorm/vs|03022026: Validate "[http://www.nlm.nih.gov/research/umls/rxnorm#1049630 ("Amoxicillin 500mg Capsule")]"
0ms http://www.nlm.nih.gov/research/umls/rxnorm/vs|03022026: Check "http://www.nlm.nih.gov/research/umls/rxnorm#1049630"
0ms http://www.nlm.nih.gov/research/umls/rxnorm/vs|03022026: CodeSystem found: http://www.nlm.nih.gov/research/umls/rxnorm|03022026 for http://www.nlm.nih.gov/research/umls/rxnorm|03022026
0ms http://www.nlm.nih.gov/research/umls/rxnorm/vs|03022026: check code in (http://www.nlm.nih.gov/research/umls/rxnorm) at CodeableConcept.coding[0]
1ms http://www.nlm.nih.gov/research/umls/rxnorm/vs|03022026: Code "1049630" found in http://www.nlm.nih.gov/research/umls/rxnorm|03022026
Wrong Display Name 'Ultrasound scan' for http://snomed.info/sct#118245000. Valid display is one of 4 choices: 'Finding by measurement' (en), 'Finding by measurement (finding)' (en), 'Measurement finding' (en) or 'Measurement finding (finding)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#118245000 ("Ultrasound scan")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#118245000"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "118245000" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Diagnostic procedure ordered' for http://snomed.info/sct#3457005. Valid display is one of 5 choices: 'Patient referral' (en), 'Patient referral, NOS' (en), 'Patient referral (procedure)' (en), 'Referral procedure' (en) or 'Referral' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#3457005 ("Diagnostic procedure ordered")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#3457005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "3457005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Ultrasound scan done' for http://snomed.info/sct#371525003. Valid display is one of 4 choices: 'Clinical procedure report (qualifier value)' (en), 'Clinical procedure report' (en), 'Report of procedure' (en) or 'Clinical procedure report (record artifact)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#371525003 ("Ultrasound scan done")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#371525003"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "371525003" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Ultrasound study date' for http://loinc.org#34574-4. Valid display is one of 3 choices: 'Pathology report final diagnosis' (en-US), 'Pathology report final diagnosis' (en-US) or 'Path report.final Dx Spec' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#34574-4 ("Ultrasound study date")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#34574-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "34574-4" found in http://loinc.org|2.82
Wrong Display Name 'Procedure not done reason' for http://snomed.info/sct#183966005. Valid display is one of 3 choices: 'Drug treatment not indicated' (en), 'Drug treatment not indicated (context-dependent category)' (en) or 'Drug treatment not indicated (situation)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#183966005 ("Procedure not done reason")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#183966005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "183966005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Equipment not available' for http://fhir.kisumuhealth.co.ke/CodeSystem/anc-reason-ultrasound-not-done#11626002. Valid display is 'Technician unavailable' (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
None of the codings provided are in the value set 'Encounter Service Type' (http://example.org/fhir/ValueSet/encounter-servicetype-vs|0.1.0), and a coding from this value set is required) (codes = http://fhir.kisumuhealth.co.ke/CodeSystem/anc-reason-ultrasound-not-done#11626002)Terminology_TX_NoValid_1_CC
Wrong Display Name 'Amniotic fluid volume' for http://loinc.org#11882-8. Valid display is one of 3 choices: 'Fetal Sex US' (en-US), 'Fetal Sex US' (en-US) or 'Fet Sex US' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11882-8 ("Amniotic fluid volume")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11882-8"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11882-8" found in http://loinc.org|2.82
None of the codings provided are in the value set 'Encounter Service Type' (http://example.org/fhir/ValueSet/encounter-servicetype-vs|0.1.0), and a coding from this value set is required) (codes = http://fhir.kisumuhealth.co.ke/CodeSystem/anc-amniotic-fluid-level-cs#386661006)Terminology_TX_NoValid_1_CC
Wrong Display Name 'Placenta location' for http://loinc.org#11876-0. Valid display is one of 3 choices: 'Fetal presentation palpation' (en-US), 'Fetal presentation palpation' (en-US) or 'Fet pres Palpation' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11876-0 ("Placenta location")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11876-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11876-0" found in http://loinc.org|2.82
Wrong Display Name 'Anterior placenta' for http://fhir.kisumuhealth.co.ke/CodeSystem/anc-placenta-location#187295000. Valid display is 'Placenta praevia' (for the language(s) 'en-US')Display_Name_for__should_be_one_of__instead_of
None of the codings provided are in the value set 'Encounter Service Type' (http://example.org/fhir/ValueSet/encounter-servicetype-vs|0.1.0), and a coding from this value set is required) (codes = http://fhir.kisumuhealth.co.ke/CodeSystem/anc-placenta-location#187295000)Terminology_TX_NoValid_1_CC
Wrong Display Name 'Oral cavity structure' for http://snomed.info/sct#368209003. Valid display is one of 4 choices: 'Right upper arm' (en), 'Right arm' (en), 'Right upper arm structure' (en) or 'Right upper arm structure (body structure)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#368209003 ("Oral cavity structure")]"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#368209003"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "368209003" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Thermometry' for http://snomed.info/sct#89003005. Valid display is one of 3 choices: 'Oral temperature taking' (en), 'Oral temperature taking (procedure)' (en) or 'Oral temperature taking (regime/therapy)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#89003005 ("Thermometry")]"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#89003005"
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "89003005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Oral temperature' for http://loinc.org#8327-9. Valid display is one of 3 choices: 'Body temperature measurement site' (en-US), 'Body temperature measurement site' (en-US) or 'Bdy temp measurement site' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8327-9 ("Oral temperature")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#8327-9"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "8327-9" found in http://loinc.org|2.82
Wrong Display Name 'Fundal height of Uterus by Tape measure' for http://loinc.org#11881-0. Valid display is one of 3 choices: 'Uterus Fundal height Tape measure' (en-US), 'Uterus Fundal height Tape measure' (en-US) or 'Uterus Fundal height Tape measure' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11881-0 ("Fundal height of Uterus by Tape measure")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#11881-0"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "11881-0" found in http://loinc.org|2.82
Wrong Display Name 'Reagin Ab [Units/volume] in Serum' for http://loinc.org#20507-0. Valid display is one of 3 choices: 'Reagin Ab [Presence] in Serum by RPR' (en-US), 'Reagin Ab [Presence] in Serum by RPR' (en-US) or 'RPR Ser Ql' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#20507-0 ("Reagin Ab [Units/volume] in Serum")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#20507-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "20507-0" found in http://loinc.org|2.82
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#882-2 ("ABO and Rh group [Type] in Blood")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#882-2"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "882-2" not found in http://loinc.org|2.82: undefined
Wrong Display Name 'Protein [Mass/volume] in Urine' for http://loinc.org#5804-0. Valid display is one of 3 choices: 'Protein [Mass/volume] in Urine by Test strip' (en-US), 'Protein [Mass/volume] in Urine by Test strip' (en-US) or 'Prot Ur Strip-mCnc' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#5804-0 ("Protein [Mass/volume] in Urine")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#5804-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "5804-0" found in http://loinc.org|2.82
Wrong Display Name 'Cervical dilation by pelvic exam' for http://loinc.org#20745-6. Valid display is one of 3 choices: 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US), 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US) or 'Carbamates Gast Ql Scn' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#20745-6 ("Cervical dilation by pelvic exam")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#20745-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "20745-6" found in http://loinc.org|2.82
Wrong Display Name 'Gravida' for http://loinc.org#11996-6. Valid display is one of 3 choices: '[#] Pregnancies' (en-US), '[#] Pregnancies' (en-US) or 'Pregnancies' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11996-6 ("Gravida")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11996-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11996-6" found in http://loinc.org|2.82
Wrong Display Name 'History of Pregnancies Narrative' for http://loinc.org#8691-8. Valid display is one of 3 choices: 'History of Travel' (en-US), 'History of Travel' (en-US) or 'Hx of Travel' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8691-8 ("History of Pregnancies Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#8691-8"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "8691-8" found in http://loinc.org|2.82
Wrong Display Name 'Gestational age Estimated from last menstrual period and ultrasound' for http://loinc.org#11884-4. Valid display is one of 3 choices: 'Gestational age Estimated' (en-US), 'Gestational age Estimated' (en-US) or 'GA Clin est' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11884-4 ("Gestational age Estimated from last menstrual period and ultrasound")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11884-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11884-4" found in http://loinc.org|2.82
Constraint failed: MustHaveMFLcode-1: 'The facility SHALL have atleast a Kenya Master Facility Code (KMFL) (identifier.slice('http://example.org/StructureDefinition/ksm-organization','KMFLCode').count() > 0)' (defined in http://fhir.kisumuhealth.co.ke/StructureDefinition/ksm-organization)http://fhir.kisumuhealth.co.ke/StructureDefinition/ksm-organization#MustHaveMFLcode-1
Constraint failed: PatientIdentification-1: 'The Patient profile SHALL have at least one identifier "NationaID" or "BirthCertificate". (identifier.slice('http://example.org/StructureDefinition/ksm-patient','NationalIDNo').count() + identifier.slice('http://example.org/StructureDefinition/ksm-patient','BirthCertificateNo').count() > 0)' (defined in http://fhir.kisumuhealth.co.ke/StructureDefinition/ksm-patient)http://fhir.kisumuhealth.co.ke/StructureDefinition/ksm-patient#PatientIdentification-1
A definition for CodeSystem 'http://terminology.hl7.org/CodeSystem/v2-0360/2.7' could not be found, so the code cannot be validated (from https://tx.fhir.org/r4) UNKNOWN_CODESYSTEM
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'MSG_DEPENDS_ON_DEPRECATED_NOTE
The string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security riskSECURITY_STRING_CONTENT_WARNING
Review the extension type for consent-decline-reason: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Hyperlink 'http://terminology.hl7.org/ValueSet/consentcategorycodes' at 'div/table/tr/td/a' for 'http://terminology.hl7.org/ValueSet/consentcategorycodes' does not resolve
Wrong Display Name 'Fundal height of Uterus by Tape measure' for http://loinc.org#11881-0. Valid display is one of 3 choices: 'Uterus Fundal height Tape measure' (en-US), 'Uterus Fundal height Tape measure' (en-US) or 'Uterus Fundal height Tape measure' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11881-0 ("Fundal height of Uterus by Tape measure")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#11881-0"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "11881-0" found in http://loinc.org|2.82
Wrong Display Name 'Fundal height of Uterus by Tape measure' for http://loinc.org#11881-0. Valid display is one of 3 choices: 'Uterus Fundal height Tape measure' (en-US), 'Uterus Fundal height Tape measure' (en-US) or 'Uterus Fundal height Tape measure' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11881-0 ("Fundal height of Uterus by Tape measure")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#11881-0"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "11881-0" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Wrong Display Name 'Reagin Ab [Units/volume] in Serum' for http://loinc.org#20507-0. Valid display is one of 3 choices: 'Reagin Ab [Presence] in Serum by RPR' (en-US), 'Reagin Ab [Presence] in Serum by RPR' (en-US) or 'RPR Ser Ql' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#20507-0 ("Reagin Ab [Units/volume] in Serum")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#20507-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "20507-0" found in http://loinc.org|2.82
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#882-2 ("ABO and Rh group [Type] in Blood")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#882-2"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "882-2" not found in http://loinc.org|2.82: undefined
Wrong Display Name 'Protein [Mass/volume] in Urine' for http://loinc.org#5804-0. Valid display is one of 3 choices: 'Protein [Mass/volume] in Urine by Test strip' (en-US), 'Protein [Mass/volume] in Urine by Test strip' (en-US) or 'Prot Ur Strip-mCnc' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#5804-0 ("Protein [Mass/volume] in Urine")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#5804-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "5804-0" found in http://loinc.org|2.82
Wrong Display Name 'Reagin Ab [Units/volume] in Serum' for http://loinc.org#20507-0. Valid display is one of 3 choices: 'Reagin Ab [Presence] in Serum by RPR' (en-US), 'Reagin Ab [Presence] in Serum by RPR' (en-US) or 'RPR Ser Ql' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#20507-0 ("Reagin Ab [Units/volume] in Serum")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#20507-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "20507-0" found in http://loinc.org|2.82
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#882-2 ("ABO and Rh group [Type] in Blood")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#882-2"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "882-2" not found in http://loinc.org|2.82: undefined
Wrong Display Name 'Protein [Mass/volume] in Urine' for http://loinc.org#5804-0. Valid display is one of 3 choices: 'Protein [Mass/volume] in Urine by Test strip' (en-US), 'Protein [Mass/volume] in Urine by Test strip' (en-US) or 'Prot Ur Strip-mCnc' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#5804-0 ("Protein [Mass/volume] in Urine")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#5804-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "5804-0" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Wrong Display Name 'Cervical dilation by pelvic exam' for http://loinc.org#20745-6. Valid display is one of 3 choices: 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US), 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US) or 'Carbamates Gast Ql Scn' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#20745-6 ("Cervical dilation by pelvic exam")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#20745-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "20745-6" found in http://loinc.org|2.82
Wrong Display Name 'Cervical dilation by pelvic exam' for http://loinc.org#20745-6. Valid display is one of 3 choices: 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US), 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US) or 'Carbamates Gast Ql Scn' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#20745-6 ("Cervical dilation by pelvic exam")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#20745-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "20745-6" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Wrong Display Name 'Gravida' for http://loinc.org#11996-6. Valid display is one of 3 choices: '[#] Pregnancies' (en-US), '[#] Pregnancies' (en-US) or 'Pregnancies' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11996-6 ("Gravida")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11996-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11996-6" found in http://loinc.org|2.82
Wrong Display Name 'History of Pregnancies Narrative' for http://loinc.org#8691-8. Valid display is one of 3 choices: 'History of Travel' (en-US), 'History of Travel' (en-US) or 'Hx of Travel' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8691-8 ("History of Pregnancies Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#8691-8"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "8691-8" found in http://loinc.org|2.82
Wrong Display Name 'Gestational age Estimated from last menstrual period and ultrasound' for http://loinc.org#11884-4. Valid display is one of 3 choices: 'Gestational age Estimated' (en-US), 'Gestational age Estimated' (en-US) or 'GA Clin est' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11884-4 ("Gestational age Estimated from last menstrual period and ultrasound")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11884-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11884-4" found in http://loinc.org|2.82
Wrong Display Name 'Gravida' for http://loinc.org#11996-6. Valid display is one of 3 choices: '[#] Pregnancies' (en-US), '[#] Pregnancies' (en-US) or 'Pregnancies' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11996-6 ("Gravida")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11996-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11996-6" found in http://loinc.org|2.82
Wrong Display Name 'History of Pregnancies Narrative' for http://loinc.org#8691-8. Valid display is one of 3 choices: 'History of Travel' (en-US), 'History of Travel' (en-US) or 'Hx of Travel' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8691-8 ("History of Pregnancies Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#8691-8"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "8691-8" found in http://loinc.org|2.82
Wrong Display Name 'Gestational age Estimated from last menstrual period and ultrasound' for http://loinc.org#11884-4. Valid display is one of 3 choices: 'Gestational age Estimated' (en-US), 'Gestational age Estimated' (en-US) or 'GA Clin est' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11884-4 ("Gestational age Estimated from last menstrual period and ultrasound")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11884-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11884-4" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Constraint failed: sdf-0: 'Name should be usable as an identifier for the module by machine processing applications such as code generation (name.matches('[A-Z]([A-Za-z0-9_]){0,254}'))'http://hl7.org/fhir/StructureDefinition/StructureDefinition#sdf-0
Wrong Display Name 'Ultrasound scan' for http://snomed.info/sct#118245000. Valid display is one of 4 choices: 'Finding by measurement' (en), 'Finding by measurement (finding)' (en), 'Measurement finding' (en) or 'Measurement finding (finding)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#118245000 ("Ultrasound scan")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#118245000"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "118245000" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Diagnostic procedure ordered' for http://snomed.info/sct#3457005. Valid display is one of 5 choices: 'Patient referral' (en), 'Patient referral, NOS' (en), 'Patient referral (procedure)' (en), 'Referral procedure' (en) or 'Referral' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#3457005 ("Diagnostic procedure ordered")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#3457005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "3457005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Ultrasound scan done' for http://snomed.info/sct#371525003. Valid display is one of 4 choices: 'Clinical procedure report (qualifier value)' (en), 'Clinical procedure report' (en), 'Report of procedure' (en) or 'Clinical procedure report (record artifact)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#371525003 ("Ultrasound scan done")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#371525003"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "371525003" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Ultrasound study date' for http://loinc.org#34574-4. Valid display is one of 3 choices: 'Pathology report final diagnosis' (en-US), 'Pathology report final diagnosis' (en-US) or 'Path report.final Dx Spec' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#34574-4 ("Ultrasound study date")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#34574-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "34574-4" found in http://loinc.org|2.82
Wrong Display Name 'Procedure not done reason' for http://snomed.info/sct#183966005. Valid display is one of 3 choices: 'Drug treatment not indicated' (en), 'Drug treatment not indicated (context-dependent category)' (en) or 'Drug treatment not indicated (situation)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#183966005 ("Procedure not done reason")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#183966005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "183966005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Amniotic fluid volume' for http://loinc.org#11882-8. Valid display is one of 3 choices: 'Fetal Sex US' (en-US), 'Fetal Sex US' (en-US) or 'Fet Sex US' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11882-8 ("Amniotic fluid volume")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11882-8"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11882-8" found in http://loinc.org|2.82
Wrong Display Name 'Placenta location' for http://loinc.org#11876-0. Valid display is one of 3 choices: 'Fetal presentation palpation' (en-US), 'Fetal presentation palpation' (en-US) or 'Fet pres Palpation' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11876-0 ("Placenta location")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11876-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11876-0" found in http://loinc.org|2.82
Wrong Display Name 'Ultrasound scan' for http://snomed.info/sct#118245000. Valid display is one of 4 choices: 'Finding by measurement' (en), 'Finding by measurement (finding)' (en), 'Measurement finding' (en) or 'Measurement finding (finding)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#118245000 ("Ultrasound scan")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#118245000"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "118245000" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Diagnostic procedure ordered' for http://snomed.info/sct#3457005. Valid display is one of 5 choices: 'Patient referral' (en), 'Patient referral, NOS' (en), 'Patient referral (procedure)' (en), 'Referral procedure' (en) or 'Referral' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#3457005 ("Diagnostic procedure ordered")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#3457005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "3457005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Ultrasound scan done' for http://snomed.info/sct#371525003. Valid display is one of 4 choices: 'Clinical procedure report (qualifier value)' (en), 'Clinical procedure report' (en), 'Report of procedure' (en) or 'Clinical procedure report (record artifact)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#371525003 ("Ultrasound scan done")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#371525003"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "371525003" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Ultrasound study date' for http://loinc.org#34574-4. Valid display is one of 3 choices: 'Pathology report final diagnosis' (en-US), 'Pathology report final diagnosis' (en-US) or 'Path report.final Dx Spec' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#34574-4 ("Ultrasound study date")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#34574-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "34574-4" found in http://loinc.org|2.82
Wrong Display Name 'Procedure not done reason' for http://snomed.info/sct#183966005. Valid display is one of 3 choices: 'Drug treatment not indicated' (en), 'Drug treatment not indicated (context-dependent category)' (en) or 'Drug treatment not indicated (situation)' (en) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
0ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Validate "[http://snomed.info/sct#183966005 ("Procedure not done reason")]"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Check "http://snomed.info/sct#183966005"
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: CodeSystem found: http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201 for http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: check code in (http://snomed.info/sct) at CodeableConcept.coding[0]
1ms http://snomed.info/sct/vs|http://snomed.info/sct/900000000000207008/version/20250201: Code "183966005" found in http://snomed.info/sct|http://snomed.info/sct/900000000000207008/version/20250201
Wrong Display Name 'Amniotic fluid volume' for http://loinc.org#11882-8. Valid display is one of 3 choices: 'Fetal Sex US' (en-US), 'Fetal Sex US' (en-US) or 'Fet Sex US' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11882-8 ("Amniotic fluid volume")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11882-8"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11882-8" found in http://loinc.org|2.82
Wrong Display Name 'Placenta location' for http://loinc.org#11876-0. Valid display is one of 3 choices: 'Fetal presentation palpation' (en-US), 'Fetal presentation palpation' (en-US) or 'Fet pres Palpation' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#11876-0 ("Placenta location")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#11876-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "11876-0" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'ultrasoundRequired' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'ultrasoundOrdered' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'ultrasoundConducted' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'ultrasoundDate' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'reasonNotDone' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'amnioticFluidLevel' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
--
StructureDefinition.snapshot (l1/c374246)
warning
The slice 'placentaLocation' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
Review the extension type for mnch-appointment-status: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-baby-immunization-started: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-blood-loss: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
The slice 'onsetDateTime' on path 'Condition.onset[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
Review the extension type for mnch-condition-of-mother: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-cotrimoxazole-mother: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-delivery-by: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-delivery-complications: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-drugs-at-delivery: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-fp-counseling: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-fp-method: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-hei-art-prophylaxis: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Review the extension type for mnch-hiv-retesting: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-infant-cotrimoxazole: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-meconium-stained-liquor: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-mode-of-delivery: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-mode-of-delivery-procedure: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-mother-haart-status: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Wrong Display Name 'Body height --at birth' for http://loinc.org#8305-5. Valid display is one of 3 choices: 'Body height --post partum' (en-US), 'Body height --post partum' (en-US) or 'Body height p partum' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8305-5 ("Body height --at birth")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#8305-5"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "8305-5" found in http://loinc.org|2.82
Wrong Display Name 'Body height --at birth' for http://loinc.org#8305-5. Valid display is one of 3 choices: 'Body height --post partum' (en-US), 'Body height --post partum' (en-US) or 'Body height p partum' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8305-5 ("Body height --at birth")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#8305-5"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "8305-5" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Review the extension type for mnch-obstructed-labour: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-place-of-delivery: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32432-7 ("Physical findings of General status Narrative")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#32432-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "32432-7" found in http://loinc.org|2.82
Wrong Display Name 'Infant feeding method' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#63895-7 ("Infant feeding method")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#63895-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "63895-7" found in http://loinc.org|2.82
Wrong Display Name 'Breastfeeding attachment' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#63895-7 ("Breastfeeding attachment")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#63895-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "63895-7" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32432-7 ("Physical findings of General status Narrative")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#32432-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "32432-7" found in http://loinc.org|2.82
Wrong Display Name 'Infant feeding method' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#63895-7 ("Infant feeding method")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#63895-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "63895-7" found in http://loinc.org|2.82
Wrong Display Name 'Breastfeeding attachment' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#63895-7 ("Breastfeeding attachment")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#63895-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "63895-7" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The concept '55284-4' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log, or see the servers logic) INACTIVE_CONCEPT_FOUND
0ms tx-op
2ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#55284-4 ("Blood pressure systolic and diastolic")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#55284-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "55284-4" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32432-7 ("Physical findings of General status Narrative")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#32432-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "32432-7" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of Breast Narrative' for http://loinc.org#32449-1. Valid display is one of 3 choices: 'Physical findings of Lung' (en-US), 'Physical findings of Lung' (en-US) or 'Phys find Lung' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32449-1 ("Physical findings of Breast Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#32449-1"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "32449-1" found in http://loinc.org|2.82
Wrong Display Name 'Vaginal discharge [Volume]' for http://loinc.org#8673-6. Valid display is one of 3 choices: 'History of Hematologic system disorders' (en-US), 'History of Hematologic system disorders' (en-US) or 'Hx of Hematologic disorders' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8673-6 ("Vaginal discharge [Volume]")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#8673-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "8673-6" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of Pelvis Narrative' for http://loinc.org#32548-0. Valid display is one of 3 choices: 'Nitroprusside reacting substances [Presence] in Urine' (en-US), 'Nitroprusside reacting substances [Presence] in Urine' (en-US) or 'Nitroprusside Test Ur Ql' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32548-0 ("Physical findings of Pelvis Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#32548-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "32548-0" found in http://loinc.org|2.82
The concept '55284-4' has a status of DISCOURAGED and its use should be reviewed (from https://tx.fhir.org/r4, see log, or see the servers logic) INACTIVE_CONCEPT_FOUND
0ms tx-op
2ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#55284-4 ("Blood pressure systolic and diastolic")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#55284-4"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "55284-4" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32432-7 ("Physical findings of General status Narrative")]"
1ms http://loinc.org/vs|2.82: Check "http://loinc.org#32432-7"
2ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
2ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
2ms http://loinc.org/vs|2.82: Code "32432-7" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of Breast Narrative' for http://loinc.org#32449-1. Valid display is one of 3 choices: 'Physical findings of Lung' (en-US), 'Physical findings of Lung' (en-US) or 'Phys find Lung' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32449-1 ("Physical findings of Breast Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#32449-1"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "32449-1" found in http://loinc.org|2.82
Wrong Display Name 'Vaginal discharge [Volume]' for http://loinc.org#8673-6. Valid display is one of 3 choices: 'History of Hematologic system disorders' (en-US), 'History of Hematologic system disorders' (en-US) or 'Hx of Hematologic disorders' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#8673-6 ("Vaginal discharge [Volume]")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#8673-6"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "8673-6" found in http://loinc.org|2.82
Wrong Display Name 'Physical findings of Pelvis Narrative' for http://loinc.org#32548-0. Valid display is one of 3 choices: 'Nitroprusside reacting substances [Presence] in Urine' (en-US), 'Nitroprusside reacting substances [Presence] in Urine' (en-US) or 'Nitroprusside Test Ur Ql' (en-US) (for the language(s) 'en-US') (from https://tx.fhir.org/r4, see log, or see the servers logic) Display_Name_for__should_be_one_of__instead_of
0ms tx-op
1ms http://loinc.org/vs|2.82: Validate "[http://loinc.org#32548-0 ("Physical findings of Pelvis Narrative")]"
2ms http://loinc.org/vs|2.82: Check "http://loinc.org#32548-0"
3ms http://loinc.org/vs|2.82: CodeSystem found: http://loinc.org|2.82 for http://loinc.org|2.82
3ms http://loinc.org/vs|2.82: check code in (http://loinc.org) at CodeableConcept.coding[0]
3ms http://loinc.org/vs|2.82: Code "32548-0" found in http://loinc.org|2.82
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)SD_PATH_SLICING_DEPRECATED
Review the extension type for mnch-pnc-timing: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Review the extension type for mnch-preeclampsia-eclampsia: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
The slice 'performedDateTime' on path 'Procedure.performed[x]' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
Review the extension type for mnch-resuscitation-done: extensions should not have a context of Element unless it's really intended that they can be used anywhereSD_CONTEXT_SHOULD_NOT_BE_ELEMENT
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Wrong Display Name 'Hypertension' for http://snomed.info/sct#73211009. Valid display is one of 4 choices: 'Diabetes mellitus' (en), 'Diabetes mellitus, NOS' (en), 'DM - Diabetes mellitus' (en) or 'Diabetes mellitus (disorder)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'Antepartum haemorrhage' for http://snomed.info/sct#67802002. Valid display is one of 3 choices: 'Malpresentation other than breech, successfully converted to cephalic presentation' (en), 'Other malpresentation successfully converted to cephalic presentation' (en) or 'Malpresentation other than breech, successfully converted to cephalic presentation (disorder)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
Wrong Display Name 'History of Cesarean delivery' for http://snomed.info/sct#161805006. Valid display is one of 11 choices: 'H/O: caesarean section' (en), 'H/O: cesarean section' (en), 'History of - cesarean section (context-dependent category)' (en), 'History of - cesarean section (situation)' (en), 'History of - cesarean section' (en), 'History of cesarean section' (en), 'History of cesarean section (situation)' (en), 'History of caesarean section' (en), 'Past pregnancy history of cesarean section (situation)' (en), 'Past pregnancy history of caesarean section' (en) or 'Past pregnancy history of cesarean section' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong codeVALUESET_CODE_CONCEPT_HINT
--
ValueSet (l1/c3471)
warning
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
The code '48723009' is not valid in the system http://snomed.info/sct (Unknown code '48723009' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '6757007' is not valid in the system http://snomed.info/sct (Unknown code '6757007' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '415068001' is not valid in the system http://snomed.info/sct (Unknown code '415068001' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '206307003' is not valid in the system http://snomed.info/sct (Unknown code '206307003' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '276596005' is not valid in the system http://snomed.info/sct (Unknown code '276596005' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))VALUESET_INCLUDE_INVALID_CONCEPT_CODE
The code '53431008' is not valid in the system http://snomed.info/sct (Unknown code '53431008' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))VALUESET_INCLUDE_INVALID_CONCEPT_CODE
--
ValueSet (l1/c5376)
warning
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
'Moderate' is no longer considered a correct display for code '6736007' (status = inactive). The correct display is one of Midgrade,Moderate (severity modifier) (qualifier value),Moderate (severity modifier),Moderate severity (from https://tx.fhir.org/r4, see log) INACTIVE_DISPLAY_FOUND
--
ValueSet (l1/c1577)
warning
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Published value sets SHOULD conform to the ShareableValueSet profile, which says that the element ValueSet.experimental is mandatory, but it is not present
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-anc-amniotic-fluid-level-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/anc-amniotic-fluid-level-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
Resource
warning
The URL 'http://example.org/fhir/ValueSet/encounter-servicetype-vs' is also used by anc-placenta-location-vs in /scratch/repo/fsh-generated/resources/ValueSet-anc-placenta-location-vs
--
Resource
warning
The URL 'http://example.org/fhir/ValueSet/encounter-servicetype-vs' is also used by anc-reason-ultrasound-not-done-vs in /scratch/repo/fsh-generated/resources/ValueSet-anc-reason-ultrasound-not-done-vs
--
Resource
warning
The URL 'http://example.org/fhir/ValueSet/encounter-servicetype-vs' is also used by encounter-servicetype-vs in /scratch/repo/fsh-generated/resources/ValueSet-encounter-servicetype-vs
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-anc-placenta-location-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/anc-placenta-location-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
Resource
warning
The URL 'http://example.org/fhir/ValueSet/encounter-servicetype-vs' has already been used by anc-amniotic-fluid-level-vs in /scratch/repo/fsh-generated/resources/ValueSet-anc-amniotic-fluid-level-vs
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-anc-reason-ultrasound-not-done-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/anc-reason-ultrasound-not-done-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
Resource
warning
The URL 'http://example.org/fhir/ValueSet/encounter-servicetype-vs' has already been used by anc-amniotic-fluid-level-vs in /scratch/repo/fsh-generated/resources/ValueSet-anc-amniotic-fluid-level-vs
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-encounter-servicetype-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/encounter-servicetype-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to matchRESOURCE_CANONICAL_MISMATCH
--
Resource
warning
The URL 'http://example.org/fhir/ValueSet/encounter-servicetype-vs' has already been used by anc-amniotic-fluid-level-vs in /scratch/repo/fsh-generated/resources/ValueSet-anc-amniotic-fluid-level-vs
Wrong Display Name 'Ultrasound scan' for http://snomed.info/sct#118245000. Valid display is one of 4 choices: 'Finding by measurement' (en), 'Finding by measurement (finding)' (en), 'Measurement finding' (en) or 'Measurement finding (finding)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound scan done' for http://snomed.info/sct#371525003. Valid display is one of 4 choices: 'Clinical procedure report (qualifier value)' (en), 'Clinical procedure report' (en), 'Report of procedure' (en) or 'Clinical procedure report (record artifact)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound study date' for http://loinc.org#34574-4. Valid display is one of 3 choices: 'Pathology report final diagnosis' (en-US), 'Pathology report final diagnosis' (en-US) or 'Path report.final Dx Spec' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Procedure not done reason' for http://snomed.info/sct#183966005. Valid display is one of 3 choices: 'Drug treatment not indicated' (en), 'Drug treatment not indicated (context-dependent category)' (en) or 'Drug treatment not indicated (situation)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Equipment not available' for http://fhir.kisumuhealth.co.ke/CodeSystem/anc-reason-ultrasound-not-done#11626002. Valid display is 'Technician unavailable' (for the language(s) 'en-US')
Wrong Display Name 'Amniotic fluid volume' for http://loinc.org#11882-8. Valid display is one of 3 choices: 'Fetal Sex US' (en-US), 'Fetal Sex US' (en-US) or 'Fet Sex US' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Placenta location' for http://loinc.org#11876-0. Valid display is one of 3 choices: 'Fetal presentation palpation' (en-US), 'Fetal presentation palpation' (en-US) or 'Fet pres Palpation' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Anterior placenta' for http://fhir.kisumuhealth.co.ke/CodeSystem/anc-placenta-location#187295000. Valid display is 'Placenta praevia' (for the language(s) 'en-US')
Wrong Display Name 'Oral cavity structure' for http://snomed.info/sct#368209003. Valid display is one of 4 choices: 'Right upper arm' (en), 'Right arm' (en), 'Right upper arm structure' (en) or 'Right upper arm structure (body structure)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Thermometry' for http://snomed.info/sct#89003005. Valid display is one of 3 choices: 'Oral temperature taking' (en), 'Oral temperature taking (procedure)' (en) or 'Oral temperature taking (regime/therapy)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Oral temperature' for http://loinc.org#8327-9. Valid display is one of 3 choices: 'Body temperature measurement site' (en-US), 'Body temperature measurement site' (en-US) or 'Bdy temp measurement site' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Fundal height of Uterus by Tape measure' for http://loinc.org#11881-0. Valid display is one of 3 choices: 'Uterus Fundal height Tape measure' (en-US), 'Uterus Fundal height Tape measure' (en-US) or 'Uterus Fundal height Tape measure' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Reagin Ab [Units/volume] in Serum' for http://loinc.org#20507-0. Valid display is one of 3 choices: 'Reagin Ab [Presence] in Serum by RPR' (en-US), 'Reagin Ab [Presence] in Serum by RPR' (en-US) or 'RPR Ser Ql' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Protein [Mass/volume] in Urine' for http://loinc.org#5804-0. Valid display is one of 3 choices: 'Protein [Mass/volume] in Urine by Test strip' (en-US), 'Protein [Mass/volume] in Urine by Test strip' (en-US) or 'Prot Ur Strip-mCnc' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Cervical dilation by pelvic exam' for http://loinc.org#20745-6. Valid display is one of 3 choices: 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US), 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US) or 'Carbamates Gast Ql Scn' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Gravida' for http://loinc.org#11996-6. Valid display is one of 3 choices: '[#] Pregnancies' (en-US), '[#] Pregnancies' (en-US) or 'Pregnancies' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'History of Pregnancies Narrative' for http://loinc.org#8691-8. Valid display is one of 3 choices: 'History of Travel' (en-US), 'History of Travel' (en-US) or 'Hx of Travel' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Gestational age Estimated from last menstrual period and ultrasound' for http://loinc.org#11884-4. Valid display is one of 3 choices: 'Gestational age Estimated' (en-US), 'Gestational age Estimated' (en-US) or 'GA Clin est' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Fundal height of Uterus by Tape measure' for http://loinc.org#11881-0. Valid display is one of 3 choices: 'Uterus Fundal height Tape measure' (en-US), 'Uterus Fundal height Tape measure' (en-US) or 'Uterus Fundal height Tape measure' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Fundal height of Uterus by Tape measure' for http://loinc.org#11881-0. Valid display is one of 3 choices: 'Uterus Fundal height Tape measure' (en-US), 'Uterus Fundal height Tape measure' (en-US) or 'Uterus Fundal height Tape measure' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Reagin Ab [Units/volume] in Serum' for http://loinc.org#20507-0. Valid display is one of 3 choices: 'Reagin Ab [Presence] in Serum by RPR' (en-US), 'Reagin Ab [Presence] in Serum by RPR' (en-US) or 'RPR Ser Ql' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Protein [Mass/volume] in Urine' for http://loinc.org#5804-0. Valid display is one of 3 choices: 'Protein [Mass/volume] in Urine by Test strip' (en-US), 'Protein [Mass/volume] in Urine by Test strip' (en-US) or 'Prot Ur Strip-mCnc' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Reagin Ab [Units/volume] in Serum' for http://loinc.org#20507-0. Valid display is one of 3 choices: 'Reagin Ab [Presence] in Serum by RPR' (en-US), 'Reagin Ab [Presence] in Serum by RPR' (en-US) or 'RPR Ser Ql' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Protein [Mass/volume] in Urine' for http://loinc.org#5804-0. Valid display is one of 3 choices: 'Protein [Mass/volume] in Urine by Test strip' (en-US), 'Protein [Mass/volume] in Urine by Test strip' (en-US) or 'Prot Ur Strip-mCnc' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Cervical dilation by pelvic exam' for http://loinc.org#20745-6. Valid display is one of 3 choices: 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US), 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US) or 'Carbamates Gast Ql Scn' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Cervical dilation by pelvic exam' for http://loinc.org#20745-6. Valid display is one of 3 choices: 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US), 'Carbamates [Presence] in Gastric fluid by Screen method' (en-US) or 'Carbamates Gast Ql Scn' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Gravida' for http://loinc.org#11996-6. Valid display is one of 3 choices: '[#] Pregnancies' (en-US), '[#] Pregnancies' (en-US) or 'Pregnancies' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'History of Pregnancies Narrative' for http://loinc.org#8691-8. Valid display is one of 3 choices: 'History of Travel' (en-US), 'History of Travel' (en-US) or 'Hx of Travel' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Gestational age Estimated from last menstrual period and ultrasound' for http://loinc.org#11884-4. Valid display is one of 3 choices: 'Gestational age Estimated' (en-US), 'Gestational age Estimated' (en-US) or 'GA Clin est' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Gravida' for http://loinc.org#11996-6. Valid display is one of 3 choices: '[#] Pregnancies' (en-US), '[#] Pregnancies' (en-US) or 'Pregnancies' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'History of Pregnancies Narrative' for http://loinc.org#8691-8. Valid display is one of 3 choices: 'History of Travel' (en-US), 'History of Travel' (en-US) or 'Hx of Travel' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Gestational age Estimated from last menstrual period and ultrasound' for http://loinc.org#11884-4. Valid display is one of 3 choices: 'Gestational age Estimated' (en-US), 'Gestational age Estimated' (en-US) or 'GA Clin est' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound scan' for http://snomed.info/sct#118245000. Valid display is one of 4 choices: 'Finding by measurement' (en), 'Finding by measurement (finding)' (en), 'Measurement finding' (en) or 'Measurement finding (finding)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound scan done' for http://snomed.info/sct#371525003. Valid display is one of 4 choices: 'Clinical procedure report (qualifier value)' (en), 'Clinical procedure report' (en), 'Report of procedure' (en) or 'Clinical procedure report (record artifact)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound study date' for http://loinc.org#34574-4. Valid display is one of 3 choices: 'Pathology report final diagnosis' (en-US), 'Pathology report final diagnosis' (en-US) or 'Path report.final Dx Spec' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Procedure not done reason' for http://snomed.info/sct#183966005. Valid display is one of 3 choices: 'Drug treatment not indicated' (en), 'Drug treatment not indicated (context-dependent category)' (en) or 'Drug treatment not indicated (situation)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Amniotic fluid volume' for http://loinc.org#11882-8. Valid display is one of 3 choices: 'Fetal Sex US' (en-US), 'Fetal Sex US' (en-US) or 'Fet Sex US' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Placenta location' for http://loinc.org#11876-0. Valid display is one of 3 choices: 'Fetal presentation palpation' (en-US), 'Fetal presentation palpation' (en-US) or 'Fet pres Palpation' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound scan' for http://snomed.info/sct#118245000. Valid display is one of 4 choices: 'Finding by measurement' (en), 'Finding by measurement (finding)' (en), 'Measurement finding' (en) or 'Measurement finding (finding)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound scan done' for http://snomed.info/sct#371525003. Valid display is one of 4 choices: 'Clinical procedure report (qualifier value)' (en), 'Clinical procedure report' (en), 'Report of procedure' (en) or 'Clinical procedure report (record artifact)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Ultrasound study date' for http://loinc.org#34574-4. Valid display is one of 3 choices: 'Pathology report final diagnosis' (en-US), 'Pathology report final diagnosis' (en-US) or 'Path report.final Dx Spec' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Procedure not done reason' for http://snomed.info/sct#183966005. Valid display is one of 3 choices: 'Drug treatment not indicated' (en), 'Drug treatment not indicated (context-dependent category)' (en) or 'Drug treatment not indicated (situation)' (en) (for the language(s) 'en-US')
Wrong Display Name 'Amniotic fluid volume' for http://loinc.org#11882-8. Valid display is one of 3 choices: 'Fetal Sex US' (en-US), 'Fetal Sex US' (en-US) or 'Fet Sex US' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Placenta location' for http://loinc.org#11876-0. Valid display is one of 3 choices: 'Fetal presentation palpation' (en-US), 'Fetal presentation palpation' (en-US) or 'Fet pres Palpation' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Body height --at birth' for http://loinc.org#8305-5. Valid display is one of 3 choices: 'Body height --post partum' (en-US), 'Body height --post partum' (en-US) or 'Body height p partum' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Body height --at birth' for http://loinc.org#8305-5. Valid display is one of 3 choices: 'Body height --post partum' (en-US), 'Body height --post partum' (en-US) or 'Body height p partum' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Infant feeding method' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Breastfeeding attachment' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Infant feeding method' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Breastfeeding attachment' for http://loinc.org#63895-7. Valid display is one of 3 choices: 'Breastfeeding status' (en-US), 'Breastfeeding status' (en-US) or 'Breastfeeding status' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of Breast Narrative' for http://loinc.org#32449-1. Valid display is one of 3 choices: 'Physical findings of Lung' (en-US), 'Physical findings of Lung' (en-US) or 'Phys find Lung' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Vaginal discharge [Volume]' for http://loinc.org#8673-6. Valid display is one of 3 choices: 'History of Hematologic system disorders' (en-US), 'History of Hematologic system disorders' (en-US) or 'Hx of Hematologic disorders' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of Pelvis Narrative' for http://loinc.org#32548-0. Valid display is one of 3 choices: 'Nitroprusside reacting substances [Presence] in Urine' (en-US), 'Nitroprusside reacting substances [Presence] in Urine' (en-US) or 'Nitroprusside Test Ur Ql' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of General status Narrative' for http://loinc.org#32432-7. Valid display is one of 3 choices: 'Physical findings of Face' (en-US), 'Physical findings of Face' (en-US) or 'Phys find Face' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of Breast Narrative' for http://loinc.org#32449-1. Valid display is one of 3 choices: 'Physical findings of Lung' (en-US), 'Physical findings of Lung' (en-US) or 'Phys find Lung' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Vaginal discharge [Volume]' for http://loinc.org#8673-6. Valid display is one of 3 choices: 'History of Hematologic system disorders' (en-US), 'History of Hematologic system disorders' (en-US) or 'Hx of Hematologic disorders' (en-US) (for the language(s) 'en-US')
Wrong Display Name 'Physical findings of Pelvis Narrative' for http://loinc.org#32548-0. Valid display is one of 3 choices: 'Nitroprusside reacting substances [Presence] in Urine' (en-US), 'Nitroprusside reacting substances [Presence] in Urine' (en-US) or 'Nitroprusside Test Ur Ql' (en-US) (for the language(s) 'en-US')
'Moderate' is no longer considered a correct display for code '6736007' (status = inactive). The correct display is one of Midgrade,Moderate (severity modifier) (qualifier value),Moderate (severity modifier),Moderate severity
The extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.3.0 is deprecated with the note: 'Use additionalBinding extension or element instead'
Conformance resource /scratch/repo/fsh-generated/resources/CodeSystem-MNCHCodes.json - the canonical URL (http://fhir.kisumuhealth.co.ke/CodeSystem/MNCHCodes) does not match the URL (http://fhir.health.go.ke/mnch/CodeSystem/MNCHCodes). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-anc-amniotic-fluid-level-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/anc-amniotic-fluid-level-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-anc-placenta-location-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/anc-placenta-location-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-anc-reason-ultrasound-not-done-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/anc-reason-ultrasound-not-done-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to match
Conformance resource /scratch/repo/fsh-generated/resources/ValueSet-encounter-servicetype-vs.json - the canonical URL (http://fhir.kisumuhealth.co.ke/ValueSet/encounter-servicetype-vs) does not match the URL (http://example.org/fhir/ValueSet/encounter-servicetype-vs). Use the special-url parameter if you really mean for it not to match
Review the extension type for consent-decline-reason: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-appointment-status: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-baby-immunization-started: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-blood-loss: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-condition-of-mother: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-cotrimoxazole-mother: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-delivery-by: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-delivery-complications: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-drugs-at-delivery: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-fp-counseling: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-fp-method: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-hei-art-prophylaxis: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-hiv-retesting: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-infant-cotrimoxazole: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-meconium-stained-liquor: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-mode-of-delivery: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-mode-of-delivery-procedure: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-mother-haart-status: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-obstructed-labour: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-place-of-delivery: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-pnc-timing: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-preeclampsia-eclampsia: extensions should not have a context of Element unless it's really intended that they can be used anywhere
Review the extension type for mnch-resuscitation-done: extensions should not have a context of Element unless it's really intended that they can be used anywhere
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
The string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk
None of the codings provided are in the value set 'Encounter Service Type' (http://example.org/fhir/ValueSet/encounter-servicetype-vs|0.1.0), and a coding from this value set is required) (codes = http://fhir.kisumuhealth.co.ke/CodeSystem/anc-reason-ultrasound-not-done#11626002)
None of the codings provided are in the value set 'Encounter Service Type' (http://example.org/fhir/ValueSet/encounter-servicetype-vs|0.1.0), and a coding from this value set is required) (codes = http://fhir.kisumuhealth.co.ke/CodeSystem/anc-amniotic-fluid-level-cs#386661006)
None of the codings provided are in the value set 'Encounter Service Type' (http://example.org/fhir/ValueSet/encounter-servicetype-vs|0.1.0), and a coding from this value set is required) (codes = http://fhir.kisumuhealth.co.ke/CodeSystem/anc-placenta-location#187295000)
Wrong Display Name 'Hypertension' for http://snomed.info/sct#73211009. Valid display is one of 4 choices: 'Diabetes mellitus' (en), 'Diabetes mellitus, NOS' (en), 'DM - Diabetes mellitus' (en) or 'Diabetes mellitus (disorder)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'Antepartum haemorrhage' for http://snomed.info/sct#67802002. Valid display is one of 3 choices: 'Malpresentation other than breech, successfully converted to cephalic presentation' (en), 'Other malpresentation successfully converted to cephalic presentation' (en) or 'Malpresentation other than breech, successfully converted to cephalic presentation (disorder)' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
Wrong Display Name 'History of Cesarean delivery' for http://snomed.info/sct#161805006. Valid display is one of 11 choices: 'H/O: caesarean section' (en), 'H/O: cesarean section' (en), 'History of - cesarean section (context-dependent category)' (en), 'History of - cesarean section (situation)' (en), 'History of - cesarean section' (en), 'History of cesarean section' (en), 'History of cesarean section (situation)' (en), 'History of caesarean section' (en), 'Past pregnancy history of cesarean section (situation)' (en), 'Past pregnancy history of caesarean section' (en) or 'Past pregnancy history of cesarean section' (en) (for the language(s) 'en, en-US'). Note that the display in the ValueSet does not have to match; this check exists to help check that it's not accidentally the wrong code
The code '48723009' is not valid in the system http://snomed.info/sct (Unknown code '48723009' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))
The code '6757007' is not valid in the system http://snomed.info/sct (Unknown code '6757007' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))
The code '415068001' is not valid in the system http://snomed.info/sct (Unknown code '415068001' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))
The code '206307003' is not valid in the system http://snomed.info/sct (Unknown code '206307003' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))
The code '276596005' is not valid in the system http://snomed.info/sct (Unknown code '276596005' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))
The code '53431008' is not valid in the system http://snomed.info/sct (Unknown code '53431008' in the CodeSystem 'http://snomed.info/sct' version 'http://snomed.info/sct/900000000000207008/version/20250201' (International Edition))