Validation Results for IHE_PDQm

Generated Mon Apr 28 18:15:57 UTC 2025, FHIR version 4.0.1 for ihe.iti.pdqm#3.1.1-current (canonical = https://profiles.ihe.net/ITI/PDQm (history)). See Errors Only & IP

Quality Checks
Publisher Version:IG Publisher Version: v1.8.25
Publication Code:n/a . PackageId = ihe.iti.pdqm, Canonical = https://profiles.ihe.net/ITI/PDQm
Realm Check for n/a:
  • n/a
Language Info:This IG has no language information
Publication Request:
RelatedIgs(None Found)
  • Publication Request is for v'3.1.0' but package version is v3.1.1-current
  • Publication Request is for version v3.1.0 which is already published
Supressed Messages:3 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. ihe.iti.pdqm3.1.1-currentR4https://profiles.ihe.net/ITI/PDQm
... hl7.terminology.r46.2.0 MR4http://terminology.hl7.orghttp://terminology.hl7.org/6.2.0
... hl7.fhir.uv.extensions.r45.2.0 MR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.2.0
... ihe.iti.balp1.1.3 MR4https://profiles.ihe.net/ITI/BALPhttps://profiles.ihe.net/ITI/BALP/1.1.3Matched to latest patch release (1.1.x->1.1.3)
.... hl7.terminology.r45.3.0 OR4http://terminology.hl7.orghttp://terminology.hl7.org/5.3.0Latest Release is 6.2.0
.... hl7.fhir.uv.extensions.r41.0.0 OR4http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0Latest Release is 5.2.0
Templates: ihe.fhir.template#0.12.1 -> fhir.base.template#0.8.1. Tools: 0.5.0
Related IGs:n/a
Dependent IGs:5 guides
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4 (details)
HTA Analysis:Non-HL7 Igs are exempt from terminology dependency analysis
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 3.1.0
IPA Comparison: n/a
IPS Comparison: n/a
Validation Flags: On: autoLoad; Off: hintAboutNonMustSupport, anyExtensionsAllowed, checkAggregation, showReferenceMessages, noExperimentalContent, displayWarnings
Summary: errors = 0, warn = 65, info = 9, broken links = 0, pinned = n/a.
FilenameErrorsWarningsHints
Build Errors000
/scratch/repo/fsh-generated/resources/AuditEvent-ex-auditPdqmMatch-consumer010
/scratch/repo/fsh-generated/resources/AuditEvent-ex-auditPdqmMatch-supplier010
/scratch/repo/fsh-generated/resources/AuditEvent-ex-auditPdqmQuery-consumer010
/scratch/repo/fsh-generated/resources/AuditEvent-ex-auditPdqmQuery-supplier010
/scratch/repo/fsh-generated/resources/Bundle-ex-QueryPatientResourceResponseMessage010
/scratch/repo/fsh-generated/resources/Bundle-ex-match-output010
/scratch/repo/fsh-generated/resources/Bundle-ex-match-output-empty010
/scratch/repo/fsh-generated/resources/Bundle-ex-match-output-error010
/scratch/repo/fsh-generated/resources/Bundle-ex-match-output-multiple010
/scratch/repo/fsh-generated/resources/Bundle-ex-match-output-warning010
/scratch/repo/fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsConsumerMatch000
/scratch/repo/fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsConsumerQuery010
/scratch/repo/fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplier020
/scratch/repo/fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplierMatch020
/scratch/repo/fsh-generated/resources/Device-ex-device000
/scratch/repo/fsh-generated/resources/ImplementationGuide-ihe.iti.pdqm000
/scratch/repo/fsh-generated/resources/OperationDefinition-PDQmMatch000
/scratch/repo/fsh-generated/resources/OperationOutcome-ex-match-failure000
/scratch/repo/fsh-generated/resources/OperationOutcome-ex-match-warning000
/scratch/repo/fsh-generated/resources/Parameters-ex-match-input-count000
/scratch/repo/fsh-generated/resources/Parameters-ex-match-input-onlyCertainMatches000
/scratch/repo/fsh-generated/resources/Parameters-ex-match-input-patient-only000
/scratch/repo/fsh-generated/resources/Patient-ex-match-input-patient000
/scratch/repo/fsh-generated/resources/Patient-ex-patient000
/scratch/repo/fsh-generated/resources/Patient-ex-patient-mothers-maiden-name000
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer0113
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier0112
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchInputPatient020
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchParametersIn000
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchParametersOut020
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.Patient020
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer0112
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier0112
/scratch/repo/fsh-generated/resources/StructureDefinition-IHE.PDQm.QueryPatientResourceResponseMessage000

n/a Show Validation Information


fsh-generated/resources/AuditEvent-ex-auditPdqmMatch-consumer.json Show Validation Information (1)

PathSeverityMessage
AuditEvent.subtype[0].system (l22/c42)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/AuditEvent-ex-auditPdqmMatch-supplier.json Show Validation Information (1)

PathSeverityMessage
AuditEvent.subtype[0].system (l23/c42)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/AuditEvent-ex-auditPdqmQuery-consumer.json Show Validation Information (1)

PathSeverityMessage
AuditEvent.subtype[0].system (l23/c42)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/AuditEvent-ex-auditPdqmQuery-supplier.json Show Validation Information (1)

PathSeverityMessage
AuditEvent.subtype[0].system (l23/c42)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/Bundle-ex-QueryPatientResourceResponseMessage.json Show Validation Information (4)

PathSeverityMessage
Bundle.link[0].url (l19/c60)warningURL value 'test.fhir.net/R4/fhir/Patient?family=Schmidt' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/Bundle-ex-match-output.json Show Validation Information (4)

PathSeverityMessage
Bundle.link[0].url (l108/c95)warningURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output.html' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/Bundle-ex-match-output-empty.json Show Validation Information (1)

PathSeverityMessage
Bundle.link[0].url (l19/c101)warningURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-empty.html' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/Bundle-ex-match-output-error.json Show Validation Information (2)

PathSeverityMessage
Bundle.link[0].url (l19/c101)warningURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-empty.html' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/Bundle-ex-match-output-multiple.json Show Validation Information (7)

PathSeverityMessage
Bundle.link[0].url (l166/c104)warningURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-multiple.html' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/Bundle-ex-match-output-warning.json Show Validation Information (5)

PathSeverityMessage
Bundle.link[0].url (l127/c103)warningURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-warning.html' does not resolve Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsConsumerMatch.json Show Validation Information (1)


fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsConsumerQuery.json Show Validation Information (1)

PathSeverityMessage
CapabilityStatement​.rest[0]​.resource[0]​.searchParam[14]​.definition (l1​/c13296)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplier.json Show Validation Information (1)

PathSeverityMessage
CapabilityStatement​.rest[0]​.resource[0]​.searchParam[21]​.definition (l1​/c14997)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
CapabilityStatement​.rest[0]​.resource[0]​.searchParam[22]​.definition (l1​/c15248)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplierMatch.json Show Validation Information (1)

PathSeverityMessage
CapabilityStatement​.rest[0]​.resource[0]​.searchParam[21]​.definition (l1​/c15769)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
CapabilityStatement​.rest[0]​.resource[0]​.searchParam[22]​.definition (l1​/c16020)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/Device-ex-device.json Show Validation Information (1)


fsh-generated/resources/ImplementationGuide-ihe.iti.pdqm.json Show Validation Information (1)


fsh-generated/resources/OperationDefinition-PDQmMatch.json Show Validation Information (1)


fsh-generated/resources/OperationOutcome-ex-match-failure.json Show Validation Information (1)


fsh-generated/resources/OperationOutcome-ex-match-warning.json Show Validation Information (1)


fsh-generated/resources/Parameters-ex-match-input-count.json Show Validation Information (4)


fsh-generated/resources/Parameters-ex-match-input-onlyCertainMatches.json Show Validation Information (4)


fsh-generated/resources/Parameters-ex-match-input-patient-only.json Show Validation Information (4)


fsh-generated/resources/Patient-ex-match-input-patient.json Show Validation Information (1)


fsh-generated/resources/Patient-ex-patient.json Show Validation Information (1)


fsh-generated/resources/Patient-ex-patient-mothers-maiden-name.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[4]​.binding​.extension[0] (l1​/c55232)informationThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated MSG_DEPENDS_ON_DEPRECATED
StructureDefinition​.snapshot​.element[12]​.pattern​.ofType(Coding)​.system (l1​/c64414)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[18]​.binding​.valueSet (l1​/c71741)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.binding​.valueSet (l1​/c98930)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[58]​.binding​.valueSet (l1​/c126428)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[78]​.binding​.valueSet (l1​/c153686)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[98]​.binding​.valueSet (l1​/c180991)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[113]​.binding​.valueSet (l1​/c202265)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[145]​.binding​.valueSet (l1​/c246919)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[163]​.binding​.valueSet (l1​/c271776)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[181]​.binding​.valueSet (l1​/c296654)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[3]​.pattern​.ofType(Coding)​.system (l1​/c310349)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[19]​.slicing​.discriminator[0] (l1​/c72270)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[106]​.slicing​.discriminator[0] (l1​/c191059)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[12]​.pattern​.ofType(Coding)​.system (l1​/c64400)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[18]​.binding​.valueSet (l1​/c71727)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.binding​.valueSet (l1​/c98916)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[58]​.binding​.valueSet (l1​/c126174)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[78]​.binding​.valueSet (l1​/c153672)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[98]​.binding​.valueSet (l1​/c180977)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[113]​.binding​.valueSet (l1​/c202251)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[145]​.binding​.valueSet (l1​/c246905)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[163]​.binding​.valueSet (l1​/c271762)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[181]​.binding​.valueSet (l1​/c296640)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[3]​.pattern​.ofType(Coding)​.system (l1​/c310335)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[19]​.slicing​.discriminator[0] (l1​/c72256)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[106]​.slicing​.discriminator[0] (l1​/c191045)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchInputPatient.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[8]​.type[0]​.profile[0] (l1​/c26593)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[3]​.type[0]​.profile[0] (l1​/c75730)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchParametersIn.json Show Validation Information (1)


fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchParametersOut.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[57]​.type[0]​.profile[0] (l1​/c107064)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/match-grade'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/match-grade' to 'http://hl7.org/fhir/StructureDefinition/match-grade|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[10]​.type[0]​.profile[0] (l1​/c173046)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/match-grade'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/match-grade' to 'http://hl7.org/fhir/StructureDefinition/match-grade|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/StructureDefinition-IHE.PDQm.Patient.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[8]​.type[0]​.profile[0] (l1​/c49338)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[3]​.type[0]​.profile[0] (l1​/c109582)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[12]​.pattern​.ofType(Coding)​.system (l1​/c64412)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[18]​.binding​.valueSet (l1​/c71745)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.binding​.valueSet (l1​/c98934)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[58]​.binding​.valueSet (l1​/c126432)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[78]​.binding​.valueSet (l1​/c153690)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[98]​.binding​.valueSet (l1​/c180995)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[113]​.binding​.valueSet (l1​/c202269)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[145]​.binding​.valueSet (l1​/c246923)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[163]​.binding​.valueSet (l1​/c271780)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[181]​.binding​.valueSet (l1​/c296658)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[3]​.pattern​.ofType(Coding)​.system (l1​/c310351)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[19]​.slicing​.discriminator[0] (l1​/c72274)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[106]​.slicing​.discriminator[0] (l1​/c191063)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.json Show Validation Information (1)

PathSeverityMessage
StructureDefinition​.snapshot​.element[12]​.pattern​.ofType(Coding)​.system (l1​/c64398)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[18]​.binding​.valueSet (l1​/c71731)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[38]​.binding​.valueSet (l1​/c98920)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[58]​.binding​.valueSet (l1​/c126178)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[78]​.binding​.valueSet (l1​/c153676)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[98]​.binding​.valueSet (l1​/c180981)warningThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[113]​.binding​.valueSet (l1​/c202255)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[145]​.binding​.valueSet (l1​/c246909)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[163]​.binding​.valueSet (l1​/c271766)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.snapshot​.element[181]​.binding​.valueSet (l1​/c296644)warningThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0' TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS
StructureDefinition​.differential​.element[3]​.pattern​.ofType(Coding)​.system (l1​/c310337)warningURL value 'urn:ihe:event-type-code' does not resolve Type_Specific_Checks_DT_URL_Resolve
StructureDefinition​.snapshot​.element[19]​.slicing​.discriminator[0] (l1​/c72260)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED
StructureDefinition​.snapshot​.element[106]​.slicing​.discriminator[0] (l1​/c191049)informationThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing) SD_PATH_SLICING_DEPRECATED

fsh-generated/resources/StructureDefinition-IHE.PDQm.QueryPatientResourceResponseMessage.json Show Validation Information (1)

Suppressed Messages (Warnings, hints, broken links)

$match bundles do not have a search string

Draft resources are known and accepted

IHE valueset that is not yet a real valueset

Errors sorted by type


MSG_DEPENDS_ON_DEPRECATED

fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThe extension http://hl7.org/fhir/StructureDefinition/elementdefinition-maxValueSet|5.2.0 is deprecated

SD_PATH_SLICING_DEPRECATED

fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThe discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)

TYPE_SPECIFIC_CHECKS_DT_CANONICAL_MULTIPLE_POSSIBLE_VERSIONS

fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsConsumerQuery.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0'
fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0'
fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0'
fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplierMatch.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0'
fsh-generated/resources/CapabilityStatement-IHE.PDQm.PatientDemographicsSupplierMatch.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName' to 'http://hl7.org/fhir/SearchParameter/patient-extensions-Patient-mothersMaidenName|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchInputPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchInputPatient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchParametersOut.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/match-grade'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/match-grade' to 'http://hl7.org/fhir/StructureDefinition/match-grade|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.MatchParametersOut.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/match-grade'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/match-grade' to 'http://hl7.org/fhir/StructureDefinition/match-grade|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Patient.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName' to 'http://hl7.org/fhir/StructureDefinition/patient-mothersMaidenName|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '3.1.0', found versions: 2.0.0, 3.1.0. Suggested fix: change the canonical reference from 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse' to 'http://terminology.hl7.org/ValueSet/v3-PurposeOfUse|3.1.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonThere are multiple different potential matches for the url 'http://hl7.org/fhir/ValueSet/object-lifecycle-events'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 1.0.0, 4.0.1, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/ValueSet/object-lifecycle-events' to 'http://hl7.org/fhir/ValueSet/object-lifecycle-events|5.2.0'

Type_Specific_Checks_DT_URL_Resolve

fsh-generated/resources/AuditEvent-ex-auditPdqmMatch-consumer.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/AuditEvent-ex-auditPdqmMatch-supplier.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/AuditEvent-ex-auditPdqmQuery-consumer.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/AuditEvent-ex-auditPdqmQuery-supplier.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/Bundle-ex-QueryPatientResourceResponseMessage.jsonURL value 'test.fhir.net/R4/fhir/Patient?family=Schmidt' does not resolve
fsh-generated/resources/Bundle-ex-match-output.jsonURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output.html' does not resolve
fsh-generated/resources/Bundle-ex-match-output-empty.jsonURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-empty.html' does not resolve
fsh-generated/resources/Bundle-ex-match-output-error.jsonURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-empty.html' does not resolve
fsh-generated/resources/Bundle-ex-match-output-multiple.jsonURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-multiple.html' does not resolve
fsh-generated/resources/Bundle-ex-match-output-warning.jsonURL value 'http://profiles.ihe.net/IHE/ITI.PDQm/branches/match/Bundle-ex-match-output-warning.html' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Consumer.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Match.Audit.Supplier.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Consumer.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonURL value 'urn:ihe:event-type-code' does not resolve
fsh-generated/resources/StructureDefinition-IHE.PDQm.Query.Audit.Supplier.jsonURL value 'urn:ihe:event-type-code' does not resolve