Basic Audit Log Patterns (BALP)
1.1.4-current - ci-build International flag

Basic Audit Log Patterns (BALP), published by IHE IT Infrastructure Technical Committee. This guide is not an authorized publication; it is the continuous build for version 1.1.4-current built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/IHE/ITI.BasicAudit/ and changes regularly. See the Directory of published versions

: Audit Example of Privacy Disclosure of a patient specific MeasureReport - JSON Representation

Raw json | Download

{
  "resourceType" : "AuditEvent",
  "id" : "ex-auditPrivacyDisclosure-measurereport",
  "meta" : {
    "profile" : [
      🔗 "https://profiles.ihe.net/ITI/BALP/StructureDefinition/IHE.BasicAudit.PrivacyDisclosure.Source"
    ],
    "security" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/v3-ActReason",
        "code" : "HTEST"
      }
    ]
  },
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: AuditEvent ex-auditPrivacyDisclosure-measurereport</b></p><a name=\"ex-auditPrivacyDisclosure-measurereport\"> </a><a name=\"hcex-auditPrivacyDisclosure-measurereport\"> </a><a name=\"ex-auditPrivacyDisclosure-measurereport-en-US\"> </a><p><b>type</b>: <a href=\"http://hl7.org/fhir/R4/codesystem-dicom-dcim.html#dicom-dcim-110106\">DICOM 110106</a>: Export</p><p><b>subtype</b>: <a href=\"http://terminology.hl7.org/6.0.2/CodeSystem-iso-21089-lifecycle.html#iso-21089-lifecycle-disclose\">ISO 21089 2017 Health Record Lifecycle Events disclose</a>: Disclose Record Lifecycle Event, <a href=\"http://hl7.org/fhir/R4/codesystem-restful-interaction.html#restful-interaction-read\">FHIR Restful Interactions read</a>: read</p><p><b>action</b>: Read/View/Print</p><p><b>recorded</b>: 2020-04-29 09:49:00+0000</p><p><b>outcome</b>: Success</p><p><b>purposeOfEvent</b>: <span title=\"Codes:{http://terminology.hl7.org/CodeSystem/v3-ActReason PATRQT}\">patient requested</span></p><blockquote><p><b>agent</b></p><p><b>type</b>: <span title=\"Codes:{http://dicom.nema.org/resources/ontology/DCM 110153}\">Source Role ID</span></p><p><b>who</b>: model number ABC, serial number 1234</p><p><b>requestor</b>: false</p><h3>Networks</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>myDevice.example.com</td><td>Machine Name</td></tr></table></blockquote><blockquote><p><b>agent</b></p><p><b>type</b>: <span title=\"Codes:{http://dicom.nema.org/resources/ontology/DCM 110152}\">Destination Role ID</span></p><p><b>who</b>: myMachine.example.org</p><p><b>requestor</b>: false</p><h3>Networks</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Address</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>http://server.example.com/fhir</td><td>URI</td></tr></table></blockquote><blockquote><p><b>agent</b></p><p><b>type</b>: <span title=\"Codes:{http://snomed.info/sct 429577009}\">Patient Advocate</span></p><p><b>who</b>: <a href=\"Patient-ex-patient.html\">John Schmidt  Other, DoB: 1923-07-25</a></p><p><b>requestor</b>: true</p></blockquote><h3>Sources</h3><table class=\"grid\"><tr><td style=\"display: none\">-</td><td><b>Site</b></td><td><b>Observer</b></td><td><b>Type</b></td></tr><tr><td style=\"display: none\">*</td><td>mobile app foo-bar</td><td>model number ABC, serial number 1234</td><td><a href=\"http://terminology.hl7.org/6.0.2/CodeSystem-security-source-type.html#security-source-type-1\">Audit Event Source Type 1</a>: User Device</td></tr></table><blockquote><p><b>entity</b></p><p><b>what</b>: <a href=\"Patient-ex-patient.html\">John Schmidt  Other, DoB: 1923-07-25</a></p><p><b>type</b>: <a href=\"http://terminology.hl7.org/6.0.2/CodeSystem-audit-entity-type.html#audit-entity-type-1\">Audit event entity type 1</a>: Person</p><p><b>role</b>: <a href=\"http://terminology.hl7.org/6.0.2/CodeSystem-object-role.html#object-role-1\">AuditEventEntityRole 1</a>: Patient</p></blockquote><blockquote><p><b>entity</b></p><p><b>what</b>: <a href=\"MeasureReport-ex-measurereport.html\">MeasureReport: status = pending; type = summary; measure = http://example.org/fhir/uv/saner/Measure/FEMADailyHospitalCOVID19Reporting; period = 2020-04-05 --&gt; 2020-04-05</a></p><p><b>type</b>: <a href=\"http://hl7.org/fhir/R4/codesystem-resource-types.html#resource-types-MeasureReport\">ResourceType MeasureReport</a>: MeasureReport</p><p><b>role</b>: <a href=\"http://terminology.hl7.org/6.0.2/CodeSystem-object-role.html#object-role-3\">AuditEventEntityRole 3</a>: Report</p></blockquote></div>"
  },
  "type" : {
    "system" : "http://dicom.nema.org/resources/ontology/DCM",
    "code" : "110106",
    "display" : "Export"
  },
  "subtype" : [
    {
      "system" : "http://terminology.hl7.org/CodeSystem/iso-21089-lifecycle",
      "code" : "disclose",
      "display" : "Disclose Record Lifecycle Event"
    },
    {
      "system" : "http://hl7.org/fhir/restful-interaction",
      "code" : "read",
      "display" : "read"
    }
  ],
  "action" : "R",
  "recorded" : "2020-04-29T09:49:00.000Z",
  "outcome" : "0",
  "purposeOfEvent" : [
    {
      "coding" : [
        {
          "system" : "http://terminology.hl7.org/CodeSystem/v3-ActReason",
          "code" : "PATRQT",
          "display" : "patient requested"
        }
      ]
    }
  ],
  "agent" : [
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://dicom.nema.org/resources/ontology/DCM",
            "code" : "110153",
            "display" : "Source Role ID"
          }
        ]
      },
      "who" : {
        "display" : "model number ABC, serial number 1234"
      },
      "requestor" : false,
      "network" : {
        "address" : "myDevice.example.com",
        "type" : "1"
      }
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://dicom.nema.org/resources/ontology/DCM",
            "code" : "110152",
            "display" : "Destination Role ID"
          }
        ]
      },
      "who" : {
        "display" : "myMachine.example.org"
      },
      "requestor" : false,
      "network" : {
        "address" : "http://server.example.com/fhir",
        "type" : "5"
      }
    },
    {
      "type" : {
        "coding" : [
          {
            "system" : "http://snomed.info/sct",
            "code" : "429577009",
            "display" : "Patient Advocate"
          }
        ]
      },
      "who" : {
        🔗 "reference" : "Patient/ex-patient"
      },
      "requestor" : true
    }
  ],
  "source" : {
    "site" : "mobile app foo-bar",
    "observer" : {
      "display" : "model number ABC, serial number 1234"
    },
    "type" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/security-source-type",
        "code" : "1",
        "display" : "User Device"
      }
    ]
  },
  "entity" : [
    {
      "what" : {
        🔗 "reference" : "Patient/ex-patient"
      },
      "type" : {
        "system" : "http://terminology.hl7.org/CodeSystem/audit-entity-type",
        "code" : "1",
        "display" : "Person"
      },
      "role" : {
        "system" : "http://terminology.hl7.org/CodeSystem/object-role",
        "code" : "1",
        "display" : "Patient"
      }
    },
    {
      "what" : {
        🔗 "reference" : "MeasureReport/ex-measurereport"
      },
      "type" : {
        "system" : "http://hl7.org/fhir/resource-types",
        "code" : "MeasureReport"
      },
      "role" : {
        "system" : "http://terminology.hl7.org/CodeSystem/object-role",
        "code" : "3",
        "display" : "Report"
      }
    }
  ]
}