Lithuanian Laboratory Implementation Guide
0.0.1 - ci-build
Lithuanian Laboratory Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-lab/ and changes regularly. See the Directory of published versions
<Observation xmlns="http://hl7.org/fhir">
<id value="observation-prostate-psad-example"/>
<meta>
<profile
value="https://hl7.lt/fhir/base/StructureDefinition/observation-lt"/>
</meta>
<language value="lt"/>
<text>
<status value="generated"/>
<div xml:lang="lt" lang="lt"><hr/><p><b>Lithuanian</b></p><hr/><p class="res-header-id"><b>Generated Narrative: Observation observation-prostate-psad-example</b></p><a name="lt-observation-prostate-psad-example"> </a><a name="lt-hcobservation-prostate-psad-example"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Language: en</p><p style="margin-bottom: 0px">Profile: <a href="https://build.fhir.org/ig/HL7LT/ig-lt-base/StructureDefinition-observation-lt.html">ObservationLt</a></p></div><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/observation-category laboratory}">Laboratory</span></p><p><b>code</b>: <span title="Codes:{http://loinc.org 15325-4}">PSA Density</span></p><p><b>subject</b>: <a href="Patient-patient-example.html">Jonas Petrauskas(official) Male, DoB: 1985-01-01 ( http://hospital-lt.lt/patient-id#HOSPLT-10005 (use: usual, ))</a></p><p><b>effective</b>: 2024-01-20 10:00:00+0000</p><p><b>value</b>: 0.18 ng/mL/cc<span style="background: LightGoldenRodYellow"> (Details: UCUM codeng/mL.cm3 = 'ng/mL.cm3')</span></p><p><b>interpretation</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation H}">Elevated density (>0.15 indicates risk)</span></p><p><b>note</b>: </p><blockquote><div><p>Calculated based on PSA of 9.0 ng/mL and Volume of 50 cc.</p>
</div></blockquote></div>
</text>
<status value="final"/>
<category>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/observation-category"/>
<code value="laboratory"/>
<display value="Laboratory"/>
</coding>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="15325-4"/>
<display value="Prostate specific Ag/Prostate volume calculated"/>
</coding>
<text value="PSA Density"/>
</code>
<subject>🔗
<reference value="Patient/patient-example"/>
</subject>
<effectiveDateTime value="2024-01-20T10:00:00Z"/>
<valueQuantity>
<value value="0.18"/>
<unit value="ng/mL/cc"/>
<system value="http://unitsofmeasure.org"/>
<code value="ng/mL.cm3"/>
</valueQuantity>
<interpretation>
<coding>
<system
value="http://terminology.hl7.org/CodeSystem/v3-ObservationInterpretation"/>
<code value="H"/>
<display value="High"/>
</coding>
<text value="Elevated density (>0.15 indicates risk)"/>
</interpretation>
<note>
<text value="Calculated based on PSA of 9.0 ng/mL and Volume of 50 cc."/>
</note>
</Observation>