Lithuanian Breast Diagnostics Implementation Guide
0.0.1 - ci-build Lithuania vėliava

Lithuanian Breast Diagnostics Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-breast/ and changes regularly. See the Directory of published versions

Pavyzdys Observation: Observation: Lesion – Right Malignant Tumor (example)


Lithuanian


Language: en

Profile: Breast Ultrasound Findings

status: Final

code: Ultrasonography of breast (procedure)

subject: Janette Petrauskaite(official) Female, DoB: 1985-01-01 ( http://hospital-lt.lt/patient-id#HOSPLT-10005 (use: usual, ))

effective: 2025-10-01 09:00:00+0000

dataAbsentReason: Not Applicable

note:

Irregular shape

bodySite: Right breast

component

code: Lesion observable

value: Malignant neoplasm of breast (disorder)

component

code: Clockface position (qualifier value)

value: 6 o'clock position (qualifier value)

component

code: Length of structure by imaging measurement

value: 15 mm (Details: UCUM codemm = 'mm')

component

code: Width of structure by imaging measurement

value: 10 mm (Details: UCUM codemm = 'mm')