Lithuanian Breast Diagnostics Implementation Guide
0.0.1 - ci-build Lithuania vėliava

Lithuanian Breast Diagnostics Implementation Guide, published by Lithuanian Medical Library. This guide is not an authorized publication; it is the continuous build for version 0.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7LT/ig-lt-breast/ and changes regularly. See the Directory of published versions

: Observation: BI-RADS 4 – Suspicious Abnormality (example)

Neapdorotas xml | Atsisiųsti


<Observation xmlns="http://hl7.org/fhir">
  <id value="observation-birads-cat4-example"/>
  <meta>
    <profile
             value="https://hl7.lt/fhir/breast/StructureDefinition/birads-assessment-lt-breast"/>
  </meta>
  <language value="lt"/>
  <text>
    <status value="generated"/>
    <div xml:lang="lt" lang="lt"><hr/><p><b>Lithuanian</b></p><hr/><p class="res-header-id"><b>Generated Narrative: Observation observation-birads-cat4-example</b></p><a name="lt-observation-birads-cat4-example"> </a><a name="lt-hcobservation-birads-cat4-example"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Language: en</p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-birads-assessment-lt-breast.html">BI-RADS Assessment</a></p></div><p><b>status</b>: Final</p><p><b>code</b>: <span title="Codes:{http://snomed.info/sct 146611000146107}">Breast Imaging Reporting and Data System assessment category (observable entity)</span></p><p><b>subject</b>: <a href="Patient-example-patient-female.html">Janette Petrauskaite(official) Female, DoB: 1985-01-01 ( http://hospital-lt.lt/patient-id#HOSPLT-10005 (use: usual, ))</a></p><p><b>effective</b>: 2023-08-01 10:00:00+0000</p><p><b>performer</b>: <a href="Practitioner-example-practitioner.html">Practitioner Registrar</a></p><p><b>value</b>: <span title="Codes:{http://snomed.info/sct 397144001}">Mammography assessment (Category 4) - Suspicious abnormality, biopsy should be considered (finding)</span></p></div>
  </text>
  <status value="final"/>
  <code>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="146611000146107"/>
      <display
               value="Breast Imaging Reporting and Data System assessment category (observable entity)"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/example-patient-female"/>
  </subject>
  <effectiveDateTime value="2023-08-01T10:00:00Z"/>
  <performer>🔗 
    <reference value="Practitioner/example-practitioner"/>
  </performer>
  <valueCodeableConcept>
    <coding>
      <system value="http://snomed.info/sct"/>
      <code value="397144001"/>
      <display
               value="Mammography assessment (Category 4) - Suspicious abnormality, biopsy should be considered (finding)"/>
    </coding>
  </valueCodeableConcept>
</Observation>