Validation Results for RealWorldData
Generated Tue May 09 16:53:07 UTC 2023, FHIR version 4.0.1 for hl7.fhir.uv.vulcan-rwd#1.0.0 (canonical = http://hl7.org/fhir/uv/vulcan-rwd (history)). See Full QA Report
Quality Checks |
Publisher Version: | IG Publisher Version: v1.3.8 |
Publication Code: | vulcan-rwd . PackageId = hl7.fhir.uv.vulcan-rwd, Canonical = http://hl7.org/fhir/uv/vulcan-rwd |
Realm Check for UV: | |
Publication Request: |
package-id | hl7.fhir.uv.vulcan-rwd |
version | 1.0.0 |
path | http://hl7.org/fhir/uv/vulcan-rwd |
mode | milestone |
status | trial-use |
sequence | STU1 |
desc | This is the first release of the published STU1 version of the guide. |
No Messages found - all good |
Supressed Messages: | 14 Suppressed Issues
|
Dependency Checks: | Package | Version | FHIR | Canonical | Web Base | Comment |
---|
hl7.fhir.uv.vulcan-rwd | 1.0.0 | R4 | http://hl7.org/fhir/uv/vulcan-rwd | | |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | Latest Release is 5.1.0 |
hl7.fhir.uv.ipa | 1.0.0 M | R4 | http://hl7.org/fhir/uv/ipa | http://hl7.org/fhir/uv/ipa/STU1 | |
hl7.terminology.r4 | 5.0.0 O | R4 | http://terminology.hl7.org | http://terminology.hl7.org/5.0.0 | see above. Latest Release is 5.1.0 |
hl7.fhir.uv.smart-app-launch | 2.0.0 O | R4 | http://hl7.org/fhir/smart-app-launch | http://hl7.org/fhir/smart-app-launch/STU2 | Latest Release is 2.1.0 |
Templates: hl7.vulcan.template#current -> hl7.fhir.template#current -> hl7.base.template#current -> fhir.base.template#current |
Dependent IGs: | no references |
Global Profiles: | (none declared) |
HTA Analysis: | All OK |
R5 Dependencies: | (none) |
Modifier Extensions: | (none) |
Previous Version Comparison: | Comparison with version 1.0.0-ballot |
IPA Comparison: | n/a |
Summary: | errors = 0, warn = 0, info = 1, broken links = 0 |
n/a Show Validation Information
Suppressed Messages (Warnings, hints, broken links)
Created a fake code system URI for EMEA product codes
- Error from server: Unable to provide support for code system http://example.org/emeaproducts (1 uses)
- The CodeSystem http://example.org/emeaproducts is unknown; The provided code http://example.org/emeaproducts#EMEA/H/C/004647 is not in the value set 'http://hl7.org/fhir/ValueSet/@all' (from Tx-Server) (0 uses)
- The code EMEA/H/C/004320 is not valid in the system http://example.org/emeaproducts (1 uses)
- The code EMEA/H/C/004647 is not valid in the system http://example.org/emeaproducts (1 uses)
Extra slices that are valid since this is an open slice
- This element does not match any known slice defined in the profile http://hl7.org/fhir/uv/vulcan-rwd/StructureDefinition/MedicationAdministrationRwd|1.0.0 (1 uses)
- This element does not match any known slice defined in the profile http://hl7.org/fhir/uv/vulcan-rwd/StructureDefinition/MedicationDispenseRwd|1.0.0 (1 uses)
MedicationDispense in FHIR Core has a mapping that includes text that looks like HTML
- The string value contains text that looks like embedded HTML tags. If this content is rendered to HTML without appropriate post-processing, it may be a security risk (1 uses)
These are valid CVX codes - checked with latest CDC listing
- The code 221 is not valid in the system http://hl7.org/fhir/sid/cvx (1 uses)
- The code 228 is not valid in the system http://hl7.org/fhir/sid/cvx (1 uses)
- The code 229 is not valid in the system http://hl7.org/fhir/sid/cvx (1 uses)
- The code 230 is not valid in the system http://hl7.org/fhir/sid/cvx (1 uses)
These are valid ICD-10-CM codes - checked with latest ICD-10-CM listing
- The code J12.82 is not valid in the system http://hl7.org/fhir/sid/icd-10-cm (1 uses)
- The code M35.81 is not valid in the system http://hl7.org/fhir/sid/icd-10-cm (1 uses)
- The code U09.9 is not valid in the system http://hl7.org/fhir/sid/icd-10-cm (1 uses)
Errors sorted by type