HL7 v2+ Specification
0.0.0 - draft
HL7 v2+ Specification, published by HL7 International. This guide is not an authorized publication; it is the continuous build for version 0.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/v2ig/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
Definitions for the PL logical model.
Guidance on how to interpret the contents of this table can be foundhere
| 0. PL | |
| Definition | Definition: This data type is used to specify a patient location within a healthcare institution. Which components are valued depends on the needs of the site. For example for a patient treated at home, only the person location type is valued. It is most commonly used for specifying patient locations, but may refer to other types of locations within a healthcare setting. Base definition for all types defined in FHIR type system. |
| Short | person locationBase for all types and resources |
| Control | 0..* |
| Is Modifier | false |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. PL.1 | |
| Short | Point of Care |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0302 (required to http://terminology.hl7.org/ValueSet/v2-0302) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 4. PL.2 | |
| Short | Room |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0303 (required to http://terminology.hl7.org/ValueSet/v2-0303) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 6. PL.3 | |
| Short | Bed |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0304 (required to http://terminology.hl7.org/ValueSet/v2-0304) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 8. PL.4 | |
| Short | Facility |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 10. PL.5 | |
| Short | Location Status |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0306 (required to http://terminology.hl7.org/ValueSet/v2-0306) |
| Type | http://hl7.org/v2/StructureDefinition/IS |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 12. PL.6 | |
| Short | Person Location Type |
| Control | 0..1 |
| Binding | The codes SHALL be taken from hl7VS-personLocationType (required to http://terminology.hl7.org/ValueSet/v2-0305) |
| Type | http://hl7.org/v2/StructureDefinition/IS |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 14. PL.7 | |
| Short | Building |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0307 (required to http://terminology.hl7.org/ValueSet/v2-0307) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 16. PL.8 | |
| Short | Floor |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0308 (required to http://terminology.hl7.org/ValueSet/v2-0308) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 18. PL.9 | |
| Short | Location Description |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/ST |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 20. PL.10 | |
| Short | Comprehensive Location Identifier |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/EI |
| 22. PL.11 | |
| Short | Assigning Authority for Location |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0363 (required to http://terminology.hl7.org/ValueSet/v2-0363) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
Guidance on how to interpret the contents of this table can be foundhere
| 0. PL | |
| Definition | Definition: This data type is used to specify a patient location within a healthcare institution. Which components are valued depends on the needs of the site. For example for a patient treated at home, only the person location type is valued. It is most commonly used for specifying patient locations, but may refer to other types of locations within a healthcare setting. |
| Short | person location |
| Control | 0..* |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. PL.1 | |
| Short | Point of Care |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0302 (required to http://terminology.hl7.org/ValueSet/v2-0302) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 4. PL.2 | |
| Short | Room |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0303 (required to http://terminology.hl7.org/ValueSet/v2-0303) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 6. PL.3 | |
| Short | Bed |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0304 (required to http://terminology.hl7.org/ValueSet/v2-0304) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 8. PL.4 | |
| Short | Facility |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 10. PL.5 | |
| Short | Location Status |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0306 (required to http://terminology.hl7.org/ValueSet/v2-0306) |
| Type | http://hl7.org/v2/StructureDefinition/IS |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 12. PL.6 | |
| Short | Person Location Type |
| Control | 0..1 |
| Binding | The codes SHALL be taken from hl7VS-personLocationType (required to http://terminology.hl7.org/ValueSet/v2-0305) |
| Type | http://hl7.org/v2/StructureDefinition/IS |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 14. PL.7 | |
| Short | Building |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0307 (required to http://terminology.hl7.org/ValueSet/v2-0307) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 16. PL.8 | |
| Short | Floor |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0308 (required to http://terminology.hl7.org/ValueSet/v2-0308) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 18. PL.9 | |
| Short | Location Description |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/ST |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 20. PL.10 | |
| Short | Comprehensive Location Identifier |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/EI |
| 22. PL.11 | |
| Short | Assigning Authority for Location |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0363 (required to http://terminology.hl7.org/ValueSet/v2-0363) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
Guidance on how to interpret the contents of this table can be foundhere
| 0. PL | |
| Definition | Definition: This data type is used to specify a patient location within a healthcare institution. Which components are valued depends on the needs of the site. For example for a patient treated at home, only the person location type is valued. It is most commonly used for specifying patient locations, but may refer to other types of locations within a healthcare setting. |
| Short | person location |
| Control | 0..* |
| Is Modifier | false |
| Logical Model | Instances of this logical model are not marked to be the target of a Reference |
| 2. PL.1 | |
| Short | Point of Care |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0302 (required to http://terminology.hl7.org/ValueSet/v2-0302) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 4. PL.2 | |
| Short | Room |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0303 (required to http://terminology.hl7.org/ValueSet/v2-0303) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 6. PL.3 | |
| Short | Bed |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0304 (required to http://terminology.hl7.org/ValueSet/v2-0304) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 8. PL.4 | |
| Short | Facility |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 10. PL.5 | |
| Short | Location Status |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0306 (required to http://terminology.hl7.org/ValueSet/v2-0306) |
| Type | http://hl7.org/v2/StructureDefinition/IS |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 12. PL.6 | |
| Short | Person Location Type |
| Control | 0..1 |
| Binding | The codes SHALL be taken from hl7VS-personLocationType (required to http://terminology.hl7.org/ValueSet/v2-0305) |
| Type | http://hl7.org/v2/StructureDefinition/IS |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 14. PL.7 | |
| Short | Building |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0307 (required to http://terminology.hl7.org/ValueSet/v2-0307) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 16. PL.8 | |
| Short | Floor |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0308 (required to http://terminology.hl7.org/ValueSet/v2-0308) |
| Type | http://hl7.org/v2/StructureDefinition/HD |
| 18. PL.9 | |
| Short | Location Description |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/ST |
| Primitive Value | This primitive element may be present, or absent, or replaced by an extension |
| 20. PL.10 | |
| Short | Comprehensive Location Identifier |
| Control | 0..1 |
| Type | http://hl7.org/v2/StructureDefinition/EI |
| 22. PL.11 | |
| Short | Assigning Authority for Location |
| Control | 0..1 |
| Binding | The codes SHALL be taken from http://terminology.hl7.org/ValueSet/v2-0363 (required to http://terminology.hl7.org/ValueSet/v2-0363) |
| Type | http://hl7.org/v2/StructureDefinition/HD |