HL7 Version 2 to FHIR
1.0.0-ballot - ballot International flag

HL7 Version 2 to FHIR, published by HL7 International / Orders and Observations. This guide is not an authorized publication; it is the continuous build for version 1.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/v2-to-fhir/ and changes regularly. See the Directory of published versions

: Segment PRTnull to PractitionerRole Map - JSON Representation

Active as of 2024-10-14

Raw json | Download

{
  "resourceType" : "ConceptMap",
  "id" : "segment-prt-to-practitionerrole",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap segment-prt-to-practitionerrole</b></p><a name=\"segment-prt-to-practitionerrole\"> </a><a name=\"hcsegment-prt-to-practitionerrole\"> </a><a name=\"segment-prt-to-practitionerrole-en-US\"> </a><p>Mapping from PRT to <a href=\"http://hl7.org/fhir/R4/practitionerrole.html\">PractitionerRole</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"5\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"3\"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan=\"3\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>vocabularymap</b></td><td><b>datatypemap</b></td><td><b>value</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td><td><b>antlr</b></td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-4</td><td style=\"border-left-width: 0px\">Role of Participation</td><td>Participation</td><td>CWE[CodeableConcept]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">code</td><td style=\"border-left-width: 0px\">code</td><td/><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-5</td><td style=\"border-left-width: 0px\">Person</td><td/><td>XCN[Practitioner]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">practitioner[Practitioner]</td><td style=\"border-left-width: 0px\">practitioner[Practitioner]</td><td/><td>While PRT may contain multiple persons within one PRT, we believe this to be rare, and when it happens, the implementer needs to determine how to best resolve that.</td></tr><tr><td style=\"border-right-width: 0px\">PRT-6</td><td style=\"border-left-width: 0px\">Person Provider Type</td><td/><td>CWE[CodeableConcept]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">specialty</td><td style=\"border-left-width: 0px\">specialty</td><td/><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-7</td><td style=\"border-left-width: 0px\">Organization Unit Type</td><td>OrganizationUnitType</td><td>CWE[CodeableConcept]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">organization[Organization.type]</td><td style=\"border-left-width: 0px\">organization[Organization.type]</td><td/><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-8</td><td style=\"border-left-width: 0px\">Organization</td><td/><td>XON[Organization]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">organization[Organization]</td><td style=\"border-left-width: 0px\">organization[Organization]</td><td/><td>While PRT may contain multiple organizations within one PRT, we believe this to be rare, and when it happens, the implementer needs to determine how to best resolve that.</td></tr><tr><td style=\"border-right-width: 0px\">PRT-9</td><td style=\"border-left-width: 0px\">Location</td><td/><td>PL[Location]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">location[Location]</td><td style=\"border-left-width: 0px\">location[Location]</td><td/><td>While PRT may contain multiple locations within one PRT, we believe this to be rare, and when it happens, the implementer needs to determine how to best resolve that.</td></tr><tr><td style=\"border-right-width: 0px\">PRT-11</td><td style=\"border-left-width: 0px\">Begin Date/Time (arrival time)</td><td/><td/><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">period.start</td><td style=\"border-left-width: 0px\">period.start</td><td/><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-12</td><td style=\"border-left-width: 0px\">End Date/Time (departure time)</td><td/><td/><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">period.end</td><td style=\"border-left-width: 0px\">period.end</td><td/><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-14</td><td style=\"border-left-width: 0px\">Address</td><td/><td>XAD[Address]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">practitioner[Practitioner.address]</td><td style=\"border-left-width: 0px\">practitioner[Practitioner.address]</td><td/><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom</td><td style=\"border-left-width: 0px\">telecom</td><td>IF PRT-23 NOT VALUED</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[1]</td><td style=\"border-left-width: 0px\">telecom[1]</td><td>IF PRT-23 IS &quot;B&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[2]</td><td style=\"border-left-width: 0px\">telecom[2]</td><td>IF PRT-23 IS &quot;C&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[3]</td><td style=\"border-left-width: 0px\">telecom[3]</td><td>IF PRT-23 IS &quot;E&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[4]</td><td style=\"border-left-width: 0px\">telecom[4]</td><td>IF PRT-23 IS &quot;F&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[5]</td><td style=\"border-left-width: 0px\">telecom[5]</td><td>IF PRT-23 IS &quot;H&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-15</td><td style=\"border-left-width: 0px\">Telecommunication Address</td><td/><td>XTN[ContactPoint]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[6]</td><td style=\"border-left-width: 0px\">telecom[6]</td><td>IF PRT-23 IS &quot;O&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;http://hl7.org/fhir/StructureDefinition/iso21090-preferred&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[1].extension[1].url</td><td style=\"border-left-width: 0px\">telecom[1].extension[1].url</td><td>IF PRT-23.1 IS &quot;B&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;true&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[1].extension[1].valueBoolean</td><td style=\"border-left-width: 0px\">telecom[1].extension[1].valueBoolean</td><td>IF PRT-23.1 IS &quot;B&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;http://hl7.org/fhir/StructureDefinition/iso21090-preferred&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[2].extension[1].url</td><td style=\"border-left-width: 0px\">telecom[2].extension[1].url</td><td>IF PRT-23.1 IS &quot;C&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;true&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[2].extension[1].valueBoolean</td><td style=\"border-left-width: 0px\">telecom[2].extension[1].valueBoolean</td><td>IF PRT-23.1 IS &quot;C&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;http://hl7.org/fhir/StructureDefinition/iso21090-preferred&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[3].extension[1].url</td><td style=\"border-left-width: 0px\">telecom[3].extension[1].url</td><td>IF PRT-23.1 IS &quot;E&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;true&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[3].extension[1].valueBoolean</td><td style=\"border-left-width: 0px\">telecom[3].extension[1].valueBoolean</td><td>IF PRT-23.1 IS &quot;E&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;http://hl7.org/fhir/StructureDefinition/iso21090-preferred&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[4].extension[1].url</td><td style=\"border-left-width: 0px\">telecom[4].extension[1].url</td><td>IF PRT-23 IS &quot;F&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;true&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[4].extension[1].valueBoolean</td><td style=\"border-left-width: 0px\">telecom[4].extension[1].valueBoolean</td><td>IF PRT-23 IS &quot;F&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;http://hl7.org/fhir/StructureDefinition/iso21090-preferred&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[5].extension[1].url</td><td style=\"border-left-width: 0px\">telecom[5].extension[1].url</td><td>IF PRT-23 IS &quot;H&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;true&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[5].extension[1].valueBoolean</td><td style=\"border-left-width: 0px\">telecom[5].extension[1].valueBoolean</td><td>IF PRT-23 IS &quot;H&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;http://hl7.org/fhir/StructureDefinition/iso21090-preferred&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[6].extension[1].url</td><td style=\"border-left-width: 0px\">telecom[6].extension[1].url</td><td>IF PRT-23 IS &quot;O&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-23</td><td style=\"border-left-width: 0px\">Preferred Method of Contact</td><td/><td/><td>&quot;true&quot;</td><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">telecom[6].extension[1].valueBoolean</td><td style=\"border-left-width: 0px\">telecom[6].extension[1].valueBoolean</td><td>IF PRT-23 IS &quot;O&quot;</td><td/></tr><tr><td style=\"border-right-width: 0px\">PRT-24</td><td style=\"border-left-width: 0px\">Contact Identifiers</td><td/><td>PLN[Identifier]</td><td/><td><a href=\"http://hl7.org/fhir/extensions/5.1.0/CodeSystem-concept-map-equivalence.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">identifier[2]</td><td style=\"border-left-width: 0px\">identifier[2]</td><td/><td/></tr></table></div>"
  },
  "extension" : [
    {
      "extension" : [
        {
          "url" : "type",
          "valueCode" : "derived-from"
        },
        {
          "url" : "label",
          "valueString" : "Segment PRT to PractitionerRole.fsh"
        },
        {
          "url" : "url",
          "valueUri" : "https://docs.google.com/spreadsheets/d/1UBY3MvsvJhw7jhUfVjywvLacO54CcnInnAkjTT0Jp5I/edit#gid=0"
        }
      ],
      "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/RelatedArtifact"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/v2mappings/segment-prt-to-practitionerrole",
  "version" : "1.0.0-ballot",
  "name" : "SegmentPRTToPractitionerRole",
  "title" : "Segment PRTnull to PractitionerRole Map",
  "status" : "active",
  "experimental" : true,
  "date" : "2024-10-14",
  "publisher" : "HL7 International / Orders and Observations",
  "contact" : [
    {
      "name" : "HL7 Orders and Observations Workgroup",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/orders"
        }
      ]
    }
  ],
  "description" : "This ConceptMap represents a mapping from the HL7 V2 Segment PRT to the FHIR PractitionerRole Resource.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "copyright" : "Copyright (c) 2020, HL7 International, Inc., All Rights Reserved.",
  "sourceUri" : "PRT",
  "targetUri" : "PractitionerRole",
  "group" : [
    {
      "element" : [
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-4",
          "display" : "Role of Participation",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "code",
              "display" : "code",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "CWE[CodeableConcept]"
                },
                {
                  "property" : "vocabulary-map",
                  "value" : "Participation"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XCN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-5",
          "display" : "Person",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Practitioner)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "practitioner[Practitioner]",
              "display" : "practitioner[Practitioner]",
              "equivalence" : "equivalent",
              "comment" : "While PRT may contain multiple persons within one PRT, we believe this to be rare, and when it happens, the implementer needs to determine how to best resolve that.",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XCN[Practitioner]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-6",
          "display" : "Person Provider Type",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "specialty",
              "display" : "specialty",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "CWE[CodeableConcept]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-7",
          "display" : "Organization Unit Type",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "CodeableConcept"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "organization[Organization.type]",
              "display" : "organization[Organization.type]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "CWE[CodeableConcept]"
                },
                {
                  "property" : "vocabulary-map",
                  "value" : "OrganizationUnitType"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XON"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-8",
          "display" : "Organization",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Organization)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "organization[Organization]",
              "display" : "organization[Organization]",
              "equivalence" : "equivalent",
              "comment" : "While PRT may contain multiple organizations within one PRT, we believe this to be rare, and when it happens, the implementer needs to determine how to best resolve that.",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XON[Organization]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "PL"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-9",
          "display" : "Location",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Reference(Location)"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "location[Location]",
              "display" : "location[Location]",
              "equivalence" : "equivalent",
              "comment" : "While PRT may contain multiple locations within one PRT, we believe this to be rare, and when it happens, the implementer needs to determine how to best resolve that.",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "PL[Location]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "DTM"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-11",
          "display" : "Begin Date/Time (arrival time)",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "dateTime"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "period.start",
              "display" : "period.start",
              "equivalence" : "equivalent"
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "DTM"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-12",
          "display" : "End Date/Time (departure time)",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "dateTime"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "period.end",
              "display" : "period.end",
              "equivalence" : "equivalent"
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XAD"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-14",
          "display" : "Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Address"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "practitioner[Practitioner.address]",
              "display" : "practitioner[Practitioner.address]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XAD[Address]"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom",
              "display" : "telecom",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 NOT VALUED"
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[1]",
              "display" : "telecom[1]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"B\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[2]",
              "display" : "telecom[2]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"C\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[3]",
              "display" : "telecom[3]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"E\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[4]",
              "display" : "telecom[4]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"F\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[5]",
              "display" : "telecom[5]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"H\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "XTN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-15",
          "display" : "Telecommunication Address",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "ContactPoint"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[6]",
              "display" : "telecom[6]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "XTN[ContactPoint]"
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"O\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[1].extension[1].url",
              "display" : "telecom[1].extension[1].url",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://hl7.org/fhir/StructureDefinition/iso21090-preferred\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23.1 IS \"B\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "boolean"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[1].extension[1].valueBoolean",
              "display" : "telecom[1].extension[1].valueBoolean",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"true\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23.1 IS \"B\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[2].extension[1].url",
              "display" : "telecom[2].extension[1].url",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://hl7.org/fhir/StructureDefinition/iso21090-preferred\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23.1 IS \"C\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "boolean"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[2].extension[1].valueBoolean",
              "display" : "telecom[2].extension[1].valueBoolean",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"true\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23.1 IS \"C\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[3].extension[1].url",
              "display" : "telecom[3].extension[1].url",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://hl7.org/fhir/StructureDefinition/iso21090-preferred\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23.1 IS \"E\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "boolean"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[3].extension[1].valueBoolean",
              "display" : "telecom[3].extension[1].valueBoolean",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"true\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23.1 IS \"E\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[4].extension[1].url",
              "display" : "telecom[4].extension[1].url",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://hl7.org/fhir/StructureDefinition/iso21090-preferred\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"F\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "boolean"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[4].extension[1].valueBoolean",
              "display" : "telecom[4].extension[1].valueBoolean",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"true\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"F\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[5].extension[1].url",
              "display" : "telecom[5].extension[1].url",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://hl7.org/fhir/StructureDefinition/iso21090-preferred\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"H\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "boolean"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[5].extension[1].valueBoolean",
              "display" : "telecom[5].extension[1].valueBoolean",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"true\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"H\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "uri"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[6].extension[1].url",
              "display" : "telecom[6].extension[1].url",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"http://hl7.org/fhir/StructureDefinition/iso21090-preferred\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"O\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "CWE"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : 1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : 1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-23",
          "display" : "Preferred Method of Contact",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "boolean"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : 1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "telecom[6].extension[1].valueBoolean",
              "display" : "telecom[6].extension[1].valueBoolean",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "value",
                  "value" : "\"true\""
                }
              ],
              "product" : [
                {
                  "property" : "antlr",
                  "value" : "IF PRT-23 IS \"O\""
                }
              ]
            }
          ]
        },
        {
          "extension" : [
            {
              "extension" : [
                {
                  "url" : "type",
                  "valueCode" : "PLN"
                },
                {
                  "url" : "cardinalityMin",
                  "valueInteger" : -1
                },
                {
                  "url" : "cardinalityMax",
                  "valueInteger" : -1
                }
              ],
              "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
            }
          ],
          "code" : "PRT-24",
          "display" : "Contact Identifiers",
          "target" : [
            {
              "extension" : [
                {
                  "extension" : [
                    {
                      "url" : "type",
                      "valueCode" : "Identifier"
                    },
                    {
                      "url" : "cardinalityMin",
                      "valueInteger" : 0
                    },
                    {
                      "url" : "cardinalityMax",
                      "valueInteger" : -1
                    }
                  ],
                  "url" : "http://hl7.org/fhir/uv/v2mappings/StructureDefinition/TypeInfo"
                }
              ],
              "code" : "identifier[2]",
              "display" : "identifier[2]",
              "equivalence" : "equivalent",
              "dependsOn" : [
                {
                  "property" : "data-type-map",
                  "value" : "PLN[Identifier]"
                }
              ]
            }
          ]
        }
      ]
    }
  ]
}