Validation Results for PharmaceuticalQualityIndustry

Generated Wed May 08 12:58:10 UTC 2024, FHIR version 5.0.0 for hl7.fhir.uv.pharm-quality#1.0.0 (canonical = http://hl7.org/fhir/uv/pharm-quality (history)). See Full QA Report

Quality Checks
Publisher Version:IG Publisher Version: v1.6.6
Publication Code:pharm-quality . PackageId = hl7.fhir.uv.pharm-quality, Canonical = http://hl7.org/fhir/uv/pharm-quality
Realm Check for UV:
  • n/a
Publication Request:
package-idhl7.fhir.uv.pharm-quality
version1.0.0
pathhttp://hl7.org/fhir/uv/pharm-quality/STU1
Pub-Modemilestone
statustrial-use
Release-LabelSTU1
sequenceSTU1
descSTU 1
No Messages found - all good
Supressed Messages:9 Suppressed Issues
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.fhir.uv.pharm-quality1.0.0R5http://hl7.org/fhir/uv/pharm-quality
... hl7.fhir.uv.extensions.r55.1.0 MR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/5.1.0
... hl7.terminology.r55.0.0 OR5http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0Latest Release is 5.5.0
Templates: hl7.fhir.template#current -> hl7.base.template#current -> fhir.base.template#current. Tools: 0.1.0
Dependent IGs:no references
Global Profiles:(none declared)
Terminology Server(s):http://tx.fhir.org/r4 (details)
HTA Analysis:All OK
R5 Dependencies:(none)
Draft Dependencies:
Modifier Extensions:(none)
Previous Version Comparison: Comparison with version 1.0.0-ballot
IPA Comparison: n/a
IPS Comparison: n/a
Summary: errors = 1, warn = 0, info = 0, broken links = 0
FilenameErrorsWarningsHints
Build Errors000
/scratch/repo/input/hl7-fhir-uv-pharm-quality100

n/a Show Validation Information


input/hl7-fhir-uv-pharm-quality.xml Show Validation Information (1)

PathSeverityMessage
ImplementationGuide​.definition​.extension[0]​.extension[0]​.value​.ofType(code) (l1​/c2879)errorThe value provided ('auto-oid-root') was not found in the value set 'ig-parameters Codes ValueSet' (http://hl7.org/fhir/tools/ValueSet/ig-parameters|0.1.0), and a code is required from this value set (error message = The System URI could not be determined for the code 'auto-oid-root' in the ValueSet 'http://hl7.org/fhir/tools/ValueSet/ig-parameters|0.1.0'; The provided code '#auto-oid-root' was not found in the value set 'http://hl7.org/fhir/tools/ValueSet/ig-parameters|0.1.0')

Editor's Comment: Known OID error

Suppressed Messages (Warnings, hints, broken links)

Chemical abstract codes (CAS) code system is specified as content 'not-present' in THO, so the code cannot be validated.

Information messages about reference to deprecated item: http://hl7.org/fhir/ValueSet/jurisdiction, which is being added by the Publisher to 7 profiles for the following base resources: ActivityDefinition, MedicinalProductDefinition, ObservationDefinition, PackagedProductDefinition, PlanDefinition, SpecimenDefinition, SubstanceDefinition. Recommendation is to ignore it for now (https://chat.fhir.org/#narrow/stream/179252-IG-creation/topic/http.3A.2F.2Fhl7.2Eorg.2Ffhir.2FValueSet.2Fjurisdiction.20deprecated.20warnin)

Information messages about reference to draft status items.

Known OID error

The EDQM code system and the 'class' and 'domain' properties that are defined in the EDQM CodeSystem resource are fully supported in tx.fhir.org. The value sets defined with these properties are being correctly expanded and rendered by the Publisher, so these messages appear to be generated due to an IG Publisher tooling issue (see IG Publisher GitHub issue: https://github.com/HL7/fhir-ig-publisher/issues/885).

This IG contains 8 example codes systems, which are not expected to be moved to THO. The concepts in the code systems are ONLY used to create value sets bound with Example binding strength and the name of each code system ends in the string "Example" to clarify that the code system is only to be used for example bindings and should not be used in production instances (see https://confluence.hl7.org/display/TSMG/Terminology+Play+Book).

Errors sorted by type


Terminology_TX_NoValid_16

input/hl7-fhir-uv-pharm-quality.xmlThe value provided ('auto-oid-root') was not found in the value set 'ig-parameters Codes ValueSet' (http://hl7.org/fhir/tools/ValueSet/ig-parameters|0.1.0), and a code is required from this value set (error message = The System URI could not be determined for the code 'auto-oid-root' in the ValueSet 'http://hl7.org/fhir/tools/ValueSet/ig-parameters|0.1.0'; The provided code '#auto-oid-root' was not found in the value set 'http://hl7.org/fhir/tools/ValueSet/ig-parameters|0.1.0')