HL7 Personal Health Record System Functional Model, Release 2, published by EHR WG. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phrsfm-ig/ and changes regularly. See the Directory of published versions

Requirements: TI.2.1.2.1 Security Event Security Audit Trigger (Function)

Official URL: http://hl7.org/ehrs/uv/phrsfmr2/Requirements/PHRSFMR2-TI.2.1.2.1 Version: 2.0.1
Standards status: Normative Computable Name: TI_2_1_2_1_Security_Event_Security_Audit_Trigger

Manage Audit Trigger initiated to track Security event.

Description I: Capture security events, both routine and exceptional, including key metadata (who, what, when, where, why).
Criteria N:
TI.2.1.2.1#01 SHALL The system SHALL audit each occurrence when security events are detected according to scope of practice, organizational policy, and/or jurisdictional law.
TI.2.1.2.1#02 SHALL The system SHALL capture identity of the organization.
TI.2.1.2.1#03 SHALL conditional IF known, THEN the system SHALL capture identity of the user.
TI.2.1.2.1#04 SHALL The system SHALL capture identity of the system.
TI.2.1.2.1#05 SHALL The system SHALL capture the event initiating audit trigger.
TI.2.1.2.1#06 SHALL The system SHALL capture the date and time of the event initiating audit trigger.
TI.2.1.2.1#07 SHALL The system SHALL capture identity of the location (i.e., network address).
TI.2.1.2.1#08 MAY The system MAY capture the rationale for the event initiating audit trigger.