HL7 Personal Health Record System Functional Model, Release 2, published by EHR WG. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phrsfm-ig/ and changes regularly. See the Directory of published versions

Requirements: RI.1.1.26 Encrypt Record Entries (Function)

Official URL: http://hl7.org/ehrs/uv/phrsfmr2/Requirements/PHRSFMR2-RI.1.1.26 Version: 2.0.1
Standards status: Normative Computable Name: RI_1_1_26_Encrypt_Record_Entries

Encrypt Record Entries (1 or more instances)

Description I: Encrypt Record Lifecycle Event - occurs when an agent causes the system to encode record entry content in a cipher. Reference: ISO 21089-2018, Section 15.26.
Criteria N:
RI.1.1.26#01 SHALL The system SHALL provide the ability to render encrypted Record Entry content based on a cipher.
RI.1.1.26#02 SHOULD The system SHOULD maintain the original and all previous versions of the Record Entry, retaining each version instance without alteration.
RI.1.1.26#03 SHOULD The system SHOULD capture a new uniquely identifiable version of the Record Entry, incorporating encrypted content.