HL7 Personal Health Record System Functional Model, Release 2
2.0.1-ballot - Normative Ballot
HL7 Personal Health Record System Functional Model, Release 2, published by EHR WG. This guide is not an authorized publication; it is the continuous build for version 2.0.1-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phrsfm-ig/ and changes regularly. See the Directory of published versions
Page standards status: Informative |
Manage Audit Trigger initiated to track user request to change password.
Capture user request to change password, both routine and exceptional, including key metadata (who, what, when, where, why).
TI.2.1.2.4#01 | SHALL |
The system SHALL audit each occurrence of user authentication when user requests password change. |
TI.2.1.2.4#02 | SHALL |
The system SHALL capture identity of the organization. |
TI.2.1.2.4#03 | conditional SHALL |
IF known, THEN the system SHALL capture identity of the user. |
TI.2.1.2.4#04 | SHALL |
The system SHALL capture identity of the system. |
TI.2.1.2.4#05 | SHALL |
The system SHALL capture the event initiating audit trigger. |
TI.2.1.2.4#06 | SHALL |
The system SHALL capture the date and time of the event initiating audit trigger. |
TI.2.1.2.4#07 | SHALL |
The system SHALL capture identity of the location (i.e., network address). |
TI.2.1.2.4#08 | MAY |
The system MAY capture the rationale for the event initiating audit trigger. |
TI.2.1.2.4#09 | conditional SHALL |
IF password change successful, THEN the system SHALL capture the new password. |