Personal Health Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
| Official URL: http://terminology.hl7.org/ValueSet/phd-devicealert-category | Version: 3.0.0-ballot | ||||
| Standards status: Trial-use | Maturity Level: 2 * | Computable Name: DeviceAlertCategoryVS | |||
| Other Identifiers: OID:2.16.840.1.113883.4.642.40.73.48.18 | |||||
Categories used to classify device alerts coming from PHD devices.
References
http://terminology.hl7.org/CodeSystem/phd-devicealert-category version 📦3.0.0-ballot
Expansion performed internally based on codesystem Device Alert Category Code System v3.0.0-ballot (CodeSystem)
This value set contains 13 concepts
| System | Code | Display (en) | Definition | JSON | XML |
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | communication-connectivity | Communication / Connectivity | Alert related to device, gateway, network, wireless, wired, or protocol connectivity issues. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | battery-power | Battery / Power | Alert related to battery level, charging state, power supply, or power source failure. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | device-signal-issue | Device / Signal Issue | Alert related to sensor attachment, signal loss, poor signal quality, missing signal, artifact, or signal acquisition failure. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | measurement-validity | Measurement Validity | Alert indicating that a measured value may be invalid, unreliable, out of measurement range, artifact-affected, or clinically/technically unusable. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | configuration | Configuration | Alert related to device, metric, alarm, threshold, profile, mode, or system configuration. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | data-acquisition | Data Acquisition | Alert related to collecting, sampling, buffering, or receiving data from a device, metric, sensor, or gateway. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | time-synchronization | Time Synchronization | Alert related to clock drift, missing timestamp, invalid timestamp, NTP/PTP failure, or inconsistent device/gateway time. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | device-gateway-malfunction | Device / Gateway Malfunction | Alert related to malfunction, fault, internal error, failed self-test, software fault, hardware fault, or gateway runtime failure. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | gateway-backend | Gateway / Backend | Alert related to gateway-to-backend processing, queueing, storage, service availability, API failure, FHIR publishing, or cloud/platform delivery. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | security | Security | Alert related to authentication, authorization, certificate, encryption, integrity, access control, or cybersecurity concern. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | environment | Environment | Related to environmental conditions. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | respiratory | Respiratory | Related to subject's respiratory function. | ||
http://terminology.hl7.org/CodeSystem/phd-devicealert-category | maintenance | Maintenance | Related to maintenance of the subject, such as a device. |