Personal Health Device Implementation Guide
3.0.0-ballot - STU 3 Ballot Global (Whole world)

Personal Health Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 3.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

ValueSet: Device Alert Category Value Set

Official URL: http://terminology.hl7.org/ValueSet/phd-devicealert-category Version: 3.0.0-ballot
Standards status: Trial-use Maturity Level: 2 * Computable Name: DeviceAlertCategoryVS
Other Identifiers: OID:2.16.840.1.113883.4.642.40.73.48.18

Categories used to classify device alerts coming from PHD devices.

References

Logical Definition (CLD)

 

Expansion

Expansion performed internally based on codesystem Device Alert Category Code System v3.0.0-ballot (CodeSystem)

This value set contains 13 concepts

SystemCodeDisplay (en)DefinitionJSONXML
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  communication-connectivityCommunication / ConnectivityAlert related to device, gateway, network, wireless, wired, or protocol connectivity issues.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  battery-powerBattery / PowerAlert related to battery level, charging state, power supply, or power source failure.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  device-signal-issueDevice / Signal IssueAlert related to sensor attachment, signal loss, poor signal quality, missing signal, artifact, or signal acquisition failure.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  measurement-validityMeasurement ValidityAlert indicating that a measured value may be invalid, unreliable, out of measurement range, artifact-affected, or clinically/technically unusable.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  configurationConfigurationAlert related to device, metric, alarm, threshold, profile, mode, or system configuration.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  data-acquisitionData AcquisitionAlert related to collecting, sampling, buffering, or receiving data from a device, metric, sensor, or gateway.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  time-synchronizationTime SynchronizationAlert related to clock drift, missing timestamp, invalid timestamp, NTP/PTP failure, or inconsistent device/gateway time.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  device-gateway-malfunctionDevice / Gateway MalfunctionAlert related to malfunction, fault, internal error, failed self-test, software fault, hardware fault, or gateway runtime failure.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  gateway-backendGateway / BackendAlert related to gateway-to-backend processing, queueing, storage, service availability, API failure, FHIR publishing, or cloud/platform delivery.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  securitySecurityAlert related to authentication, authorization, certificate, encryption, integrity, access control, or cybersecurity concern.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  environmentEnvironmentRelated to environmental conditions.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  respiratoryRespiratoryRelated to subject's respiratory function.
http://terminology.hl7.org/CodeSystem/phd-devicealert-category  maintenanceMaintenanceRelated to maintenance of the subject, such as a device.

Description of the above table(s).