Personal Health Device Implementation Guide, published by HL7 International / Devices. This guide is not an authorized publication; it is the continuous build for version 3.0.0-draft built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
{
"resourceType" : "DeviceMetric",
"id" : "bp-devicemetric-example",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDeviceMetric"
]
},
"language" : "en",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: DeviceMetric bp-devicemetric-example</b></p><a name=\"bp-devicemetric-example\"> </a><a name=\"hcbp-devicemetric-example\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\"/><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-PhdDeviceMetric.html\">PhdDeviceMetric</a></p></div><p><b>status</b>: Active</p><p><b>category</b>: <span title=\"Codes:{http://hl7.org/fhir/metric-category measurement}\">Measurement</span></p><p><b>type</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 150020}\">MDC_PRESS_BLD_NONINV</span></p><p><b>device</b>: <a href=\"Device-phd-711000FEFF5F49B0.B0495F001071.html\">Device: identifier = IEEE 11073 System Identifier,Bluetooth MAC address; manufacturer = OMRONHEALTHCARE; serialNumber = 20150200002A; modelNumber = HEM-9200T; type = MDC_MOC_VMS_MDS_SIMP</a></p><p><b>unit</b>: <span title=\"Codes:{urn:iso:std:iso:11073:10101 266016}, {http://unitsofmeasure.org mm[Hg]}\">MDC_DIM_MMHG</span></p><p><b>measurementFrequency</b>: 0.067 Hz<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codeHz = 'Hz')</span></p></div>"
},
"status" : "active",
"category" : {
"coding" : [
{
"system" : "http://hl7.org/fhir/metric-category",
"code" : "measurement"
}
]
},
"type" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "150020",
"display" : "MDC_PRESS_BLD_NONINV"
}
]
},
"device" : {
🔗 "reference" : "Device/phd-711000FEFF5F49B0.B0495F001071"
},
"unit" : {
"coding" : [
{
"system" : "urn:iso:std:iso:11073:10101",
"code" : "266016",
"display" : "MDC_DIM_MMHG"
},
{
"system" : "http://unitsofmeasure.org",
"code" : "mm[Hg]",
"display" : "mm[Hg]"
}
]
},
"measurementFrequency" : {
"value" : 0.067,
"unit" : "Hz",
"system" : "http://unitsofmeasure.org",
"code" : "Hz"
}
}