Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 2.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/uv/phd/ValueSet/DeviceTypes11073MDC | Version: 2.1.0 | |||
Standards status: Trial-use | Maturity Level: 3 | Computable Name: DeviceTypes11073MDC |
ValueSet for the ISO/IEEE 11073-10101 Nomenclature Codes for Device Specialization types
References
ValueSet for the ISO/IEEE 11073-10101 Nomenclatures Describing Device specialization types such as blood pressure, pulse oximeter, thermometer, ECG, etc.. This value set will grow as new specializations are defined.
Most of the codes included in this value set are from partition 'infra' which has value 8. The 32-bit code for the pulse oximeter, which has term code 4100 in partition 'infra', is given by 524288 + 4100 = 528388.
The display value consists of the nomenclature code's reference identifier. Devices exchange the numerical codes in the IEEE 11073 communication standards, not reference identifiers, but the reference identifiers are often used where human readability are more important than efficiency or bandwidth. However, only the numerical codes are guaranteed to be unique.
Generated Narrative: ValueSet DeviceTypes11073MDC
Profile: Shareable ValueSet
urn:iso:std:iso:11073:10101
Code | Display |
528385 | MDC_DEV_SPEC_PROFILE_INFUS |
528384 | MDC_DEV_SPEC_PROFILE_HYDRA |
528388 | MDC_DEV_SPEC_PROFILE_PULS_OXIM |
528390 | MDC_DEV_SPEC_PROFILE_ECG |
528391 | MDC_DEV_SPEC_PROFILE_BP |
528392 | MDC_DEV_SPEC_PROFILE_TEMP |
528397 | MDC_DEV_SPEC_PROFILE_CALC_PULM |
528399 | MDC_DEV_SPEC_PROFILE_SCALE |
528401 | MDC_DEV_SPEC_PROFILE_GLUCOSE |
528402 | MDC_DEV_SPEC_PROFILE_COAG |
528403 | MDC_DEV_SPEC_PROFILE_INSULIN_PUMP |
528404 | MDC_DEV_SPEC_PROFILE_BCA |
528405 | MDC_DEV_SPEC_PROFILE_PEFM |
528406 | MDC_DEV_SPEC_PROFILE_URINE_ANALYZER |
528408 | MDC_DEV_SPEC_PROFILE_SABTE |
528409 | MDC_DEV_SPEC_PROFILE_CGM |
528412 | MDC_DEV_SPEC_PROFILE_PSM |
528413 | MDC_DEV_SPEC_PROFILE_SPIRO |
528425 | MDC_DEV_SPEC_PROFILE_HF_CARDIO |
528426 | MDC_DEV_SPEC_PROFILE_HF_STRENGTH |
528455 | MDC_DEV_SPEC_PROFILE_AI_ACTIVITY_HUB |
528456 | MDC_DEV_SPEC_PROFILE_AI_MED_MINDER |
528457 | MDC_DEV_SPEC_PROFILE_GENERIC |
528484 | MDC_DEV_SUB_SPEC_PROFILE_STEP_COUNTER |
528501 | MDC_DEV_SUB_SPEC_PROFILE_FALL_SENSOR |
528502 | MDC_DEV_SUB_SPEC_PROFILE_PERS_SENSOR |
528503 | MDC_DEV_SUB_SPEC_PROFILE_SMOKE_SENSOR |
528504 | MDC_DEV_SUB_SPEC_PROFILE_CO_SENSOR |
528505 | MDC_DEV_SUB_SPEC_PROFILE_WATER_SENSOR |
528506 | MDC_DEV_SUB_SPEC_PROFILE_GAS_SENSOR |
528507 | MDC_DEV_SUB_SPEC_PROFILE_MOTION_SENSOR |
528508 | MDC_DEV_SUB_SPEC_PROFILE_PROPEXIT_SENSOR |
528509 | MDC_DEV_SUB_SPEC_PROFILE_ENURESIS_SENSOR |
528510 | MDC_DEV_SUB_SPEC_PROFILE_CONTACTCLOSURE_SENSOR |
528511 | MDC_DEV_SUB_SPEC_PROFILE_USAGE_SENSOR |
528512 | MDC_DEV_SUB_SPEC_PROFILE_SWITCH_SENSOR |
528513 | MDC_DEV_SUB_SPEC_PROFILE_DOSAGE_SENSOR |
528514 | MDC_DEV_SUB_SPEC_PROFILE_TEMP_SENSOR |
528524 | MDC_DEV_SUB_SPEC_PROFILE_ECG |
528525 | MDC_DEV_SUB_SPEC_PROFILE_HR |
528532 | MDC_DEV_SUB_SPEC_PROFILE_CPAP |
528533 | MDC_DEV_SUB_SPEC_PROFILE_CPAP_AUTO |
528534 | MDC_DEV_SUB_SPEC_PROFILE_BPAP |
528535 | MDC_DEV_SUB_SPEC_PROFILE_BPAP_AUTO |
528536 | MDC_DEV_SUB_SPEC_PROFILE_ACSV |
ValueSet
Expansion from tx.fhir.org based on codesystem ISO 11073-10101 Health informatics - Point-of-care version2023-04-26
This value set contains 45 concepts
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |