Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 2.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

ValueSet: ANS1ToHL7 codes for measurement attributes

Official URL: http://hl7.org/fhir/uv/phd/ValueSet/ASN1measurement Version: 2.1.0
Standards status: Trial-use Maturity Level: 3 Computable Name: ASN1measurement

ValueSet for the ANS1ToHL7 codes that are derived from enumeration measurements.

References

Logical Definition (CLD)

Generated Narrative: ValueSet ASN1measurement

 

Expansion

ValueSet

Expansion performed internally based on codesystem ASN1 bits to HL7 enumerated values v2.1.0 (CodeSystem)

This value set contains 104 concepts

CodeSystemDisplay (en-US)Definition
  67846.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7lim-alert-off

Both the high and the low limit alerts are disabled

  67846.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7lim-low-off

The low limit alert is disabled

  67846.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7lim-high-off

The high limit alert is disabled

  150604.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-disconnected

The device is not connected with the sensor

  150604.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-malfunction

The sensor has malfunctioned

  150604.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-displaced

The sensor is not correctly placed on the user

  150604.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-unsupported

The sensor connected to the device is unsupported

  150604.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-off

The sensor is not connected to the user

  150604.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-interference

The sensor is experiencing interference

  150604.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-searching

The sensor is searching for a signal

  150604.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-pulse-questionable

A questionable pulse has been detected

  150604.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-non-pulsatile

A non pulsatile signal has been detected

  150604.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-erratic

A signal has been discovered, but it is erratic

  150604.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-low-perfusion

The signal is experiencing low perfusion

  150604.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-poor

The signal has been discovered, but it is poor

  150604.12http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-inadequate

The signal has been discovered, but it is inadequate

  150604.13http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7signal-processing-irregularity

The signal has been discovered, but is experiencing processing irregularity

  150604.14http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-equipment-malfunction

A device malfunction has occurred

  150604.15http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-extended-update

An extended display update is in progress on device

  150605.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-nominal

No abnormalities have been detected by the sensor

  150605.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-marginal

The pulse quality is marginal

  150605.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-minimal

The pulse quality is minimal

  150605.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-qual-unacceptable

The pulse quality is unacceptable

  8410584.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss

Loss of unspecified lead wire or electrode connection

  8410584.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss

Loss of unspecified lead signal

  8410584.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss-first-lead

Loss of 1st lead wire or electrode connection

  8410584.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss-first-lead

Loss of 1st lead signal

  8410584.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss-second-lead

Loss of 2nd lead wire or electrode connection

  8410584.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss-second-lead

Loss of 2nd lead signal

  8410584.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadwire-loss-third-lead

Loss of 3rd lead wire or electrode connection

  8410584.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7leadsignal-loss-third-lead

Loss of 3rd lead signal

  8417752.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-battery-low

The device battery is low

  8417752.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-malfunction

The sensor has malfunctioned

  8417752.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-sample-size-insufficient

The sensor's sample size is insufficient

  8417752.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-strip-insertion

The test strip was inserted incorrectly

  8417752.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-strip-type-incorrect

The test strip type is incompatable with the sensor

  8417752.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-high

The value reported by the sensor is too high

  8417752.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-low

The value reported by the sensor is too low

  8417752.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-high

The temperature is too high

  8417752.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-low

The temperature is too low

  8417752.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-read-interrupt

The read process was interrupted

  8417752.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-gen-fault

General Device Fault

  8417752.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-out-of-range

The temperature is out of range

  8417909.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-device-battery-low

The INR device battery is low

  8417909.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-malfunction

The INR device sensor has malfunctioned

  8417909.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-sample-size-insufficient

The sample size was insufficient

  8417909.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-strip-insertion

The test script was inserted incorrectly

  8417909.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-strip-type-incorrect

The test strip used is not compatible with the INR

  8417909.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-result-too-high

The test result is too high

  8417909.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-result-too-low

The test result is too low

  8417909.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-temp-too-high

The temperature is too high

  8417909.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-temp-too-low

The temperature is too low

  8417909.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-read-interrupt

The read process was interrupted

  8417909.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-device-gen-fault

General device fault

  8417909.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7inr-sensor-calibration-due

The INR sensor calibration is due

  8408608.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-undetermined

Undetermined device status event

  8408608.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-reset

Device reset

  8408608.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error

Device error

  8408608.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-mechanical

Mechanical error

  8408608.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-electronic

Electronic error

  8408608.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-software

Software error

  8408608.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-error-battery

Battery error

  8408608.15http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service

Undetermined device status event, service needed

  8408608.16http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service-time-sync-required

Time sync service required

  8408608.17http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service-calibration-required

Calibration required

  8408608.18http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-service-replenishment-required

Replenishment required

  8408608.25http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-low

Battery power is too low

  8408608.26http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-depleted

Battery is depleted

  8408608.27http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-replaced

Battery has been replaced

  8408608.28http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-status-battery-interrupted

Battery was interrupted

  8418060.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-session-stopped

Session stopped

  8418060.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-type-incorrect

Sensor type incorrect for device

  8418060.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-malfunction

The sensor malfunctioned

  8418060.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7device-specific-alert

Device specific alert

  8418060.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-calibration-not-allowed

Calibrating the sensor is not allowed

  8418060.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-calibration-recommended

Calibrating the sensor is recommended

  8418060.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-calibration-required

Calibrating the sensor is required

  8418060.10http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-high

Temperature is too high for a valid result

  8418060.11http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-temp-too-low

Temperature is too low for a valid result

  8418060.12http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-below-patient-low

Sensor result below the Patient Low level

  8418060.13http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-above-patient-high

Sensor result above the Patient High level

  8418060.14http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-low-hypo

Sensor result below level

  8418060.15http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-high-hyper

Sensor result above level

  8418060.16http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-rate-decrease-exceeded

The sensor rate of decrease has been exceeded

  8418060.17http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-rate-increase-exceeded

The sensor rate of increase has been exceeded

  8418060.18http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-low

Sensor result is lower than the device can process

  8418060.19http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-result-too-high

Sensor result is higher than the device can process

  8418060.20http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7sensor-com-out-of-range

The sensor communication is out of range

  8418512.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-status-Undetermined

The status of the battery is unknown

  8418512.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-absent

The battery is absent

  8418512.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-active

The battery is active in the system

  8418512.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-charging

The battery is charging

  8418512.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-fullyCharged

The battery is fully charged

  8418512.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-disposable

The battery is disposable

  8418512.6http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-rechargeable

The battery is rechargable

  8418512.7http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-overTemperature

The battery is too hot

  8418512.8http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-faulty

The battery is faulty

  8418512.9http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7Battery-incompatible

The battery is incompatible

  8410608.0http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7body-movement

Too much body movement

  8410608.1http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7cuff-too-loose

The cuff was too loose

  8410608.2http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7irregular-pulse

An irregular pulse was detected

  8410608.3http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-over-range-limit

The pulse was too high for sensor to work

  8410608.4http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7pulse-under-range-limit

The pulse was too low for sensor to work

  8410608.5http://hl7.org/fhir/uv/phd/CodeSystem/ASN1ToHL7improper-body-position

The cuff was incorrectly placed with respect to the heart


Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code