Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 2.0.0-ballot2 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

: ANS1ToHL7 codes defined for Boolean Clock attributes - XML Representation

Page standards status: Trial-use Maturity Level: 1

Raw xml | Download


<ValueSet xmlns="http://hl7.org/fhir">
  <id value="ASN1ClockBits"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/StructureDefinition/shareablevalueset"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ValueSet ASN1ClockBits</b></p><a name="ASN1ClockBits"> </a><a name="hcASN1ClockBits"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="http://hl7.org/fhir/R4/shareablevalueset.html">Shareable ValueSet</a></p></div><ul><li>Include these codes as defined in <a href="CodeSystem-ASN1ToHL7.html"><code>http://terminology.hl7.org/CodeSystem/ASN1ToHL7</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.460">68219.0</a></td><td style="color: #cccccc">mds-time-capab-real-time-clock</td><td>Real time clock is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.461">68219.1</a></td><td style="color: #cccccc">mds-time-capab-set-clock</td><td>Support for the PHG to set the time</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.462">68219.2</a></td><td style="color: #cccccc">mds-time-capab-relative-time</td><td>Relative Time is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.463">68219.3</a></td><td style="color: #cccccc">mds-time-capab-high-res-relative-time</td><td>Hi-Res Relative Time is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.464">68219.4</a></td><td style="color: #cccccc">mds-time-capab-sync-abs-time</td><td>Syncing the absolute time is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.465">68219.5</a></td><td style="color: #cccccc">mds-time-capab-sync-rel-time</td><td>Syncing the relative time is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.466">68219.6</a></td><td style="color: #cccccc">mds-time-capab-sync-hi-res-relative-time</td><td>Syncing hi-res relative time is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.467">68219.7</a></td><td style="color: #cccccc">mds-time-capab-bo-time</td><td>The real-time clock supports base offset time</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.468">68219.8</a></td><td style="color: #cccccc">mds-time-state-abs-time-synced</td><td>The absolute time has been synced</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.469">68219.9</a></td><td style="color: #cccccc">mds-time-state-rel-time-synced</td><td>The relative time has been synced</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.4610">68219.10</a></td><td style="color: #cccccc">mds-time-state-hi-res-relative-time-synced</td><td>The hi-res time has been synced</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.4611">68219.11</a></td><td style="color: #cccccc">mds-time-mgr-set-time</td><td>PHG Requested to set the time</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.4612">68219.12</a></td><td style="color: #cccccc">mds-time-capab-sync-bo-time</td><td>Syncing base-offset time is supported</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.4613">68219.13</a></td><td style="color: #cccccc">mds-time-state-bo-time-synced</td><td>Base-offset time has been synced</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.4614">68219.14</a></td><td style="color: #cccccc">mds-time-state-bo-time-UTC-aligned</td><td>Base-offset time is aligned with UTC time standard</td></tr><tr><td><a href="CodeSystem-ASN1ToHL7.html#ASN1ToHL7-68219.4615">68219.15</a></td><td style="color: #cccccc">mds-time-dst-rules-enabled</td><td>Support for daylight savings time rules</td></tr></table></li></ul></div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="dev"/>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-fmm">
    <valueInteger value="1">
      <extension
                 url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
        <valueCanonical
                        value="http://hl7.org/fhir/uv/phd/ImplementationGuide/hl7.fhir.uv.phd"/>
      </extension>
    </valueInteger>
  </extension>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-standards-status">
    <valueCode value="trial-use">
      <extension
                 url="http://hl7.org/fhir/StructureDefinition/structuredefinition-conformance-derivedFrom">
        <valueCanonical
                        value="http://hl7.org/fhir/uv/phd/ImplementationGuide/hl7.fhir.uv.phd"/>
      </extension>
    </valueCode>
  </extension>
  <url value="http://hl7.org/fhir/uv/phd/ValueSet/ASN1ClockBits"/>
  <version value="2.0.0-ballot2"/>
  <name value="ASN1ClockBits"/>
  <title value="ANS1ToHL7 codes defined for Boolean Clock attributes"/>
  <status value="active"/>
  <experimental value="false"/>
  <date value="2018-09-17"/>
  <publisher value="HL7 International / Health Care Devices"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/healthcaredevices"/>
    </telecom>
  </contact>
  <description
               value="ValueSet for the ANS1ToHL7 codes that are not derived from enumeration measurements."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
    </coding>
  </jurisdiction>
  <compose>
    <include>
      <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
      <concept>
        <code value="68219.0"/>
      </concept>
      <concept>
        <code value="68219.1"/>
      </concept>
      <concept>
        <code value="68219.2"/>
      </concept>
      <concept>
        <code value="68219.3"/>
      </concept>
      <concept>
        <code value="68219.4"/>
      </concept>
      <concept>
        <code value="68219.5"/>
      </concept>
      <concept>
        <code value="68219.6"/>
      </concept>
      <concept>
        <code value="68219.7"/>
      </concept>
      <concept>
        <code value="68219.8"/>
      </concept>
      <concept>
        <code value="68219.9"/>
      </concept>
      <concept>
        <code value="68219.10"/>
      </concept>
      <concept>
        <code value="68219.11"/>
      </concept>
      <concept>
        <code value="68219.12"/>
      </concept>
      <concept>
        <code value="68219.13"/>
      </concept>
      <concept>
        <code value="68219.14"/>
      </concept>
      <concept>
        <code value="68219.15"/>
      </concept>
    </include>
  </compose>
</ValueSet>