Personal Health Device Implementation Guide
2.0.0-ballot2 - STU 2 - Ballot International flag

Personal Health Device Implementation Guide, published by HL7 International / Health Care Devices. This guide is not an authorized publication; it is the continuous build for version 2.0.0-ballot2 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/phd/ and changes regularly. See the Directory of published versions

: Example of PHD Device - XML Representation

Page standards status: Informative

Raw xml | Download


<Device xmlns="http://hl7.org/fhir">
  <id value="phd-74E8FFFEFF051C00.001C05FFE874"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/phd/StructureDefinition/PhdDevice"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Device phd-74E8FFFEFF051C00.001C05FFE874</b></p><a name="phd-74E8FFFEFF051C00.001C05FFE874"> </a><a name="hcphd-74E8FFFEFF051C00.001C05FFE874"> </a><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px"/><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-PhdDevice.html">PhdDevice</a></p></div><p><b>identifier</b>: IEEE 11073 System Identifier/74-E8-FF-FE-FF-05-1C-00, Bluetooth MAC address/00-1C-05-FF-E8-74</p><p><b>manufacturer</b>: Nonin_Medical_Inc.</p><p><b>serialNumber</b>: 501900083</p><p><b>modelNumber</b>: Model 3230</p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 65573}">Simple PHD</span></p><h3>Specializations</h3><table class="grid"><tr><td style="display: none">-</td><td><b>SystemType</b></td><td><b>Version</b></td></tr><tr><td style="display: none">*</td><td><span title="Codes:{urn:iso:std:iso:11073:10101 528388}">Pulse Oximeter</span></td><td>1</td></tr></table><blockquote><p><b>version</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 531976}">Firmware revision</span></p><p><b>value</b>: r2.1</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 531975}">Software revision</span></p><p><b>value</b>: r1.5 9.7</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 531974}">Hardware revision</span></p><p><b>value</b>: r1.0</p></blockquote><blockquote><p><b>version</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 532352}">Continua version</span></p><p><b>value</b>: 6.0</p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 532353}">Each element of the certified interfaces list as a separate property</span></p><p><b>valueCode</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs 32772}">Bluetooth LE Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 532353}">Each element of the certified interfaces list as a separate property</span></p><p><b>valueCode</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs 8196}">PHDC USB Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 532353}">Each element of the certified interfaces list as a separate property</span></p><p><b>valueCode</b>: <span title="Codes:{http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs 4}">Pulse Oximeter certified</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/ASN1ToHL7 532354.0}">negated-regulation-status</span></p><p><b>valueCode</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 N}">No</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 68220}">Time synchronization protocol</span></p><p><b>valueCode</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 532224}">MDC_TIME_SYNC_NONE</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/ASN1ToHL7 68219.0}">mds-time-capab-real-time-clock</span></p><p><b>valueCode</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">real time clock supported</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/ASN1ToHL7 68219.1}">mds-time-capab-set-clock</span></p><p><b>valueCode</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">setting the time supported</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/ASN1ToHL7 68219.2}">mds-time-capab-relative-time</span></p><p><b>valueCode</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0136 Y}">relative time supported</span></p></blockquote><blockquote><p><b>property</b></p><p><b>type</b>: <span title="Codes:{urn:iso:std:iso:11073:10101 68223}">MDC_TIME_RES_REL: relative time clock resolution</span></p><p><b>valueQuantity</b>: 1000 us<span style="background: LightGoldenRodYellow"> (Details: UCUM  codeus = 'us')</span></p></blockquote></div>
  </text>
  <identifier>
    <type>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/>
        <code value="SYSID"/>
        <display value="IEEE 11073 System Identifier"/>
      </coding>
    </type>
    <system value="urn:oid:1.2.840.10004.1.1.1.0.0.1.0.0.1.2680"/>
    <value value="74-E8-FF-FE-FF-05-1C-00"/>
  </identifier>
  <identifier>
    <type>
      <coding>
        <system
                value="http://terminology.hl7.org/CodeSystem/ContinuaDeviceIdentifiers"/>
        <code value="BTMAC"/>
        <display value="Bluetooth MAC address"/>
      </coding>
    </type>
    <system value="http://hl7.org/fhir/sid/eui-48/bluetooth"/>
    <value value="00-1C-05-FF-E8-74"/>
  </identifier>
  <manufacturer value="Nonin_Medical_Inc."/>
  <serialNumber value="501900083"/>
  <modelNumber value="Model 3230"/>
  <type>
    <coding>
      <system value="urn:iso:std:iso:11073:10101"/>
      <code value="65573"/>
      <display value="MDC_MOC_VMS_MDS_SIMP"/>
    </coding>
    <text value="Simple PHD"/>
  </type>
  <specialization>
    <systemType>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="528388"/>
        <display value="MDC_DEV_SPEC_PROFILE_PULS_OXIM"/>
      </coding>
      <text value="Pulse Oximeter"/>
    </systemType>
    <version value="1"/>
  </specialization>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="531976"/>
        <display value="MDC_ID_PROD_SPEC_FW"/>
      </coding>
      <text value="Firmware revision"/>
    </type>
    <value value="r2.1"/>
  </version>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="531975"/>
        <display value="MDC_ID_PROD_SPEC_SW"/>
      </coding>
      <text value="Software revision"/>
    </type>
    <value value="r1.5 9.7"/>
  </version>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="531974"/>
        <display value="MDC_ID_PROD_SPEC_HW"/>
      </coding>
      <text value="Hardware revision"/>
    </type>
    <value value="r1.0"/>
  </version>
  <version>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532352"/>
        <display value="MDC_REG_CERT_DATA_CONTINUA_VERSION"/>
      </coding>
      <text value="Continua version"/>
    </type>
    <value value="6.0"/>
  </version>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532353"/>
        <display value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"/>
      </coding>
      <text
            value="Each element of the certified interfaces list as a separate property"/>
    </type>
    <valueCode>
      <coding>
        <system
                value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs"/>
        <code value="32772"/>
        <display value="Bluetooth LE Pulse Oximeter certified"/>
      </coding>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532353"/>
        <display value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"/>
      </coding>
      <text
            value="Each element of the certified interfaces list as a separate property"/>
    </type>
    <valueCode>
      <coding>
        <system
                value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs"/>
        <code value="8196"/>
        <display value="PHDC USB Pulse Oximeter certified"/>
      </coding>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532353"/>
        <display value="MDC_REG_CERT_DATA_CONTINUA_CERT_DEV_LIST"/>
      </coding>
      <text
            value="Each element of the certified interfaces list as a separate property"/>
    </type>
    <valueCode>
      <coding>
        <system
                value="http://hl7.org/fhir/uv/phd/CodeSystem/ContinuaPHDInterfaceIDs"/>
        <code value="4"/>
        <display value="Pulse Oximeter certified"/>
      </coding>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
        <code value="532354.0"/>
        <display value="negated-regulation-status"/>
      </coding>
    </type>
    <valueCode>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
        <code value="N"/>
      </coding>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="68220"/>
        <display value="MDC_TIME_SYNC_PROTOCOL"/>
      </coding>
      <text value="Time synchronization protocol"/>
    </type>
    <valueCode>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="532224"/>
        <display value="MDC_TIME_SYNC_NONE"/>
      </coding>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
        <code value="68219.0"/>
        <display value="mds-time-capab-real-time-clock"/>
      </coding>
    </type>
    <valueCode>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
        <code value="Y"/>
      </coding>
      <text value="real time clock supported"/>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
        <code value="68219.1"/>
        <display value="mds-time-capab-set-clock"/>
      </coding>
    </type>
    <valueCode>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
        <code value="Y"/>
      </coding>
      <text value="setting the time supported"/>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/ASN1ToHL7"/>
        <code value="68219.2"/>
        <display value="mds-time-capab-relative-time"/>
      </coding>
    </type>
    <valueCode>
      <coding>
        <system value="http://terminology.hl7.org/CodeSystem/v2-0136"/>
        <code value="Y"/>
      </coding>
      <text value="relative time supported"/>
    </valueCode>
  </property>
  <property>
    <type>
      <coding>
        <system value="urn:iso:std:iso:11073:10101"/>
        <code value="68223"/>
      </coding>
      <text value="MDC_TIME_RES_REL: relative time clock resolution"/>
    </type>
    <valueQuantity>
      <value value="1000"/>
      <system value="http://unitsofmeasure.org"/>
      <code value="us"/>
    </valueQuantity>
  </property>
</Device>