IHE SDC/electronic Cancer Protocols (eCPs) on FHIR, published by HL7 International / Orders and Observations. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/ihe-sdc-ecc-on-fhir/ and changes regularly. See the Directory of published versions
: SDC eCP Observation List Item Response Example - XML Representation
Raw xml | Download
<Observation xmlns="http://hl7.org/fhir">
<id value="SDCeCCObservationCodeLIR"/>
<meta>
<profile
value="http://hl7.org/fhir/uv/ihe-sdc-ecc/StructureDefinition/ihe-sdc-ecc-Observation"/>
</meta>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b>Generated Narrative: Observation</b><a name="SDCeCCObservationCodeLIR"> </a></p><div style="display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%"><p style="margin-bottom: 0px">Resource Observation "SDCeCCObservationCodeLIR" </p><p style="margin-bottom: 0px">Profile: <a href="StructureDefinition-ihe-sdc-ecc-Observation.html">IHE SDC/eCP on FHIR Observation</a></p></div><p><b>identifier</b>: Accession ID: SDCeCCObservationCodeEx0 (use: USUAL)</p><p><b>status</b>: final</p><p><b>code</b>: Tumor size (Note A) <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.3.0/CodeSystem-CAPeCC.html">College of American Pathologists (CAP) eCC (electronic Cancer Checklists)</a>#2129)</span></p><p><b>subject</b>: <a href="http://example.org/patient">http://example.org/patient: Example Patient</a></p><p><b>effective</b>: 2021-05-11</p><p><b>performer</b>: <a href="http://example.org/practitioner">http://example.org/practitioner: Example Practitioner</a></p><p><b>value</b>: Greatest Dimension in cm <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.3.0/CodeSystem-CAPeCC.html">College of American Pathologists (CAP) eCC (electronic Cancer Checklists)</a>#2123)</span></p><h3>Components</h3><table class="grid"><tr><td style="display: none">-</td><td><b>Code</b></td><td><b>Value[x]</b></td></tr><tr><td style="display: none">*</td><td>Greatest Dimension in cm <span style="background: LightGoldenRodYellow; margin: 4px; border: 1px solid khaki"> (<a href="http://terminology.hl7.org/5.3.0/CodeSystem-CAPeCC.html">College of American Pathologists (CAP) eCC (electronic Cancer Checklists)</a>#2123)</span></td><td>2 cm</td></tr></table></div>
</text>
<identifier>
<use value="usual"/>
<type>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0203"/>
<code value="ACSN"/>
<display value="Accession ID"/>
</coding>
</type>
<system value="http://example.org/Observation"/>
<value value="SDCeCCObservationCodeEx0"/>
</identifier>
<status value="final"/>
<code>
<coding>
<system value="http://cap.org/eCC"/>
<code value="2129"/>
<display value="Tumor size (Note A)"/>
</coding>
</code>
<subject>
<reference value="http://example.org/patient"/>
<display value="Example Patient"/>
</subject>
<effectiveDateTime value="2021-05-11"/>
<performer>
<reference value="http://example.org/practitioner"/>
<display value="Example Practitioner"/>
</performer>
<valueCodeableConcept>
<coding>
<system value="http://cap.org/eCC"/>
<code value="2123"/>
<display value="Greatest Dimension in cm"/>
</coding>
</valueCodeableConcept>
<component>
<code>
<coding>
<system value="http://cap.org/eCC"/>
<code value="2123"/>
<display value="Greatest Dimension in cm"/>
</coding>
</code>
<valueQuantity>
<value value="2"/>
<unit value="cm"/>
</valueQuantity>
</component>
</Observation>