This IG is version 5.0.0, while the IG 'hl7.fhir.uv.application-feature' is from version 4.0.1
error
There is no jira specification file defined with the expected name of FHIR-tx-ecosystem in the xml folder of the https://github.com/HL7/Jira-Spec-Artifacts project. This must exist before ballot or publication.
ecosystem.html
information
The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'These parameters SHALL be supported by all servers:'CONFORMANCE_STATEMENT_WORD
languages.html
information
The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'Servers SHALL support all four approaches'CONFORMANCE_STATEMENT_WORD
requirements.html
information
The html source contains the word 'SHALL' but it is not in a text phrase marked as a conformance clause: 'The server SHALL return a CapabilitiesStatement from /metadata'CONFORMANCE_STATEMENT_WORD
testcases.html
information
The html source contains the word 'SHOULD' but it is not in a text phrase marked as a conformance clause: 'The tests assume that the server can accept code systems on the fly. If servers do not accept code systems on the fly, server authors will have to adapt these tests by rewriting them for their own actual support code systems. Either way, servers that do SHOULD pass all the tests, but the FHIR product director will review the test outcomes in order to approve a server.'CONFORMANCE_STATEMENT_WORD
The System URI could not be determined for the code 'director' in the ValueSet 'http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0'UNABLE_TO_INFER_CODESYSTEM
The value provided ('director') was not found in the value set 'hl7 workgroup value set' (http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0), and a code is required from this value set (error message = The System URI could not be determined for the code 'director' in the ValueSet 'http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0'; The provided code '#director' was not found in the value set 'http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0')Terminology_TX_NoValid_16
Reference to experimental CodeSystem http://hl7.org/fhir/guide-parameter-code|5.0.0MSG_EXPERIMENTAL
ImplementationGuide (l1/c8659)
error
The nominated WG 'director' is unknownVALIDATION_HL7_WG_UNKNOWN
ImplementationGuide.dependsOn[2] (l1/c2830)
warning
The ImplementationGuide is based on FHIR version 5.0.0 but package hl7.fhir.uv.application-feature#1.0.0-ballot is based on FHIR version 4.0.1. In general, this version mismatch should be avoided - some tools will try to make this work with variable degrees of success, but others will not even tryIG_DEPENDENCY_VERSION_WARNING
The ImplementationGuide is based on FHIR version 5.0.0 but package hl7.fhir.uv.application-feature#1.0.0-ballot is based on FHIR version 4.0.1. In general, this version mismatch should be avoided - some tools will try to make this work with variable degrees of success, but others will not even try
The value provided ('director') was not found in the value set 'hl7 workgroup value set' (http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0), and a code is required from this value set (error message = The System URI could not be determined for the code 'director' in the ValueSet 'http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0'; The provided code '#director' was not found in the value set 'http://hl7.org/fhir/ValueSet/hl7-work-group|5.2.0')