SMART Health Cards: Vaccination & Testing Implementation Guide
0.6.2 - STU 1 (Ballot Version) International flag

SMART Health Cards: Vaccination & Testing Implementation Guide, published by HL7 International - Public Health Work Group. This is not an authorized publication; it is the continuous build for version 0.6.2). This version is based on the current content of https://github.com/HL7/fhir-shc-vaccination-ig/ and changes regularly. See the Directory of published versions

ValueSet: Qualitative lab result findings

Official URL: http://hl7.org/fhir/uv/shc-vaccination/ValueSet/qualitative-lab-result-findings Version: 0.6.2
Active as of 2023-06-01 Computable Name: QualitativeLabResultFindings

This value set includes codes for identifying laboratory test results. It includes SNOMED CT codes from a value set of COVID-19-related SNOMED CT codes, as well as codes from LOINC answer lists with roughly equivalent meanings. While the source value set is COVID-19-related, these codes should apply to all infectious disease-related qualitative laboratory results.

References

Logical Definition (CLD)

This value set includes codes based on the following rules:

 

Expansion

This value set contains 20 concepts

Expansion based on:

CodeSystemDisplay
  10828004http://snomed.info/sctPositive (qualifier value)
  125154007http://snomed.info/sctSpecimen unsatisfactory for evaluation (finding)
  260373001http://snomed.info/sctDetected (qualifier value)
  260385009http://snomed.info/sctNegative (qualifier value)
  260408008http://snomed.info/sctWeakly positive (qualifier value)
  260415000http://snomed.info/sctNot detected (qualifier value)
  419984006http://snomed.info/sctInconclusive (qualifier value)
  42425007http://snomed.info/sctEquivocal (qualifier value)
  455371000124106http://snomed.info/sctInvalid result (qualifier value)
  720735008http://snomed.info/sctPresumptive positive (qualifier value)
  82334004http://snomed.info/sctIndeterminate (qualifier value)
  LA11882-0http://loinc.orgDetected
  LA11883-8http://loinc.orgNot detected
  LA11885-3http://loinc.orgEquivocal
  LA9663-1http://loinc.orgInconclusive
  LA13548-5http://loinc.orgSpecimen unsatisfactory for evaluation
  LA6577-6http://loinc.orgNegative
  LA4259-3http://loinc.orgBorderline
  LA6576-8http://loinc.orgPositive
  LA18996-1http://loinc.orgStrong positive

Explanation of the columns that may appear on this page:

Level A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies
System The source of the definition of the code (when the value set draws in codes defined elsewhere)
Code The code (used as the code in the resource instance)
Display The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application
Definition An explanation of the meaning of the concept
Comments Additional notes about how to use the code