Radiation Dose Summary for Diagnostic Procedures on FHIR, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-radiation-dose-summary-ig/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/uv/radiation-dose-summary/StructureDefinition/modality-device | Version: 0.1.0 | |||
Draft as of 2024-07-10 | Computable Name: ModalityDevice |
Modality profiling as a Device resource
Usage:
Description of Profiles, Differentials, Snapshots and how the different presentations work.
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier Slice: Unordered, Open by pattern:type | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device Serial Number, related to tag(0018,1000) Device Serial Number |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Serial Number | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() ![]() |
S | 1..1 | Identifier | Describes the AETitle of the modality irradiating the patient |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: application-entity | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Application Entity | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device UID, related to tag(0018,1002) Device UID |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-uid | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device UID | |
![]() ![]() ![]() ![]() ![]() |
0..1 | uri | The namespace for the identifier value Required Pattern: urn:dicom:uid | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device ID, related to tag((0018,1003) Device ID |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-id | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device ID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() |
S | 0..1 | string | The manufacturer of the modality, related to tag(0008,0070) manufacturer |
![]() ![]() ![]() |
S | 0..1 | string | The serial number of the modality, which is the Device Serial Number |
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The manufacturer of the modality |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: manufacturer-name | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The model name of the modality |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: model-name | |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Describes the main modality type (CT, MG, etc.) Binding: Modality (required) |
![]() ![]() ![]() |
0..* | BackboneElement | Describes the Software Versions of the device, related to tag(0018,1020) Software Versions | |
![]() |
Path | Conformance | ValueSet | URI |
Device.type | required | Modalityhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html |
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier Slice: Unordered, Open by pattern:type | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device Serial Number, related to tag(0018,1000) Device Serial Number |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Serial Number | |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() ![]() |
S | 1..1 | Identifier | Describes the AETitle of the modality irradiating the patient |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: application-entity | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Application Entity | |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device UID, related to tag(0018,1002) Device UID |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-uid | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device UID | |
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Required Pattern: urn:dicom:uid |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device ID, related to tag((0018,1003) Device ID |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-id | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device ID | |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() ![]() |
S | 0..1 | string | The manufacturer of the modality, related to tag(0008,0070) manufacturer |
![]() ![]() ![]() |
S | 0..1 | string | The serial number of the modality, which is the Device Serial Number |
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The manufacturer of the modality |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: manufacturer-name | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The model name of the modality |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Describes the main modality type (CT, MG, etc.) Binding: Modality (required) |
![]() ![]() ![]() |
0..* | BackboneElement | Describes the Software Versions of the device, related to tag(0018,1020) Software Versions | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | The version text | |
![]() |
Path | Conformance | ValueSet / Code | URI |
Device.identifier:deviceSerialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:deviceSerialNumber.type | extensible | Pattern: SNO("Serial Number")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.identifier:aeTitle.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:aeTitle.type | extensible | Pattern: application-entity("Application Entity")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.identifier:deviceUID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:deviceUID.type | extensible | Pattern: device-uid("Device UID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.identifier:deviceID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:deviceID.type | extensible | Pattern: device-id("Device ID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.deviceName:manufacturer.type | required | Pattern: manufacturer-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.deviceName:manufacturerModelName.type | required | Pattern: model-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.type | required | Modalityhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html |
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
1..* | Identifier | Instance identifier Slice: Unordered, Open by pattern:type | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device Serial Number, related to tag(0018,1000) Device Serial Number | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Serial Number | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() ![]() |
S | 1..1 | Identifier | Describes the AETitle of the modality irradiating the patient | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: application-entity | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Application Entity | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device UID, related to tag(0018,1002) Device UID | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-uid | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device UID | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Required Pattern: urn:dicom:uid | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device ID, related to tag((0018,1003) Device ID | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-id | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device ID | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
![]() ![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() ![]() |
0..1 | string | The distinct identification string | |||||
![]() ![]() ![]() |
S | 0..1 | string | The manufacturer of the modality, related to tag(0008,0070) manufacturer | ||||
![]() ![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||
![]() ![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
![]() ![]() ![]() |
0..1 | string | Lot number of manufacture | |||||
![]() ![]() ![]() |
S | 0..1 | string | The serial number of the modality, which is the Device Serial Number | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The manufacturer of the modality | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: manufacturer-name | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The model name of the modality | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |||||
![]() ![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Describes the main modality type (CT, MG, etc.) Binding: Modality (required) | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..* | BackboneElement | Describes the Software Versions of the device, related to tag(0018,1020) Software Versions | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
![]() |
Path | Conformance | ValueSet / Code | URI | |||
Device.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.identifier:deviceSerialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:deviceSerialNumber.type | extensible | Pattern: SNO("Serial Number")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.identifier:aeTitle.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:aeTitle.type | extensible | Pattern: application-entity("Application Entity")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.identifier:deviceUID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:deviceUID.type | extensible | Pattern: device-uid("Device UID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.identifier:deviceID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:deviceID.type | extensible | Pattern: device-id("Device ID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.deviceName:manufacturer.type | required | Pattern: manufacturer-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.deviceName:manufacturerModelName.type | required | Pattern: model-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | Modalityhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html |
This structure is derived from Device
Summary
Mandatory: 5 elements(6 nested mandatory elements)
Must-Support: 9 elements
Slices
This structure defines the following Slices:
Differential View
This structure is derived from Device
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier Slice: Unordered, Open by pattern:type | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device Serial Number, related to tag(0018,1000) Device Serial Number |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Serial Number | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() ![]() |
S | 1..1 | Identifier | Describes the AETitle of the modality irradiating the patient |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: application-entity | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Application Entity | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device UID, related to tag(0018,1002) Device UID |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-uid | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device UID | |
![]() ![]() ![]() ![]() ![]() |
0..1 | uri | The namespace for the identifier value Required Pattern: urn:dicom:uid | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device ID, related to tag((0018,1003) Device ID |
![]() ![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Description of identifier Required Pattern: At least the following | |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-id | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device ID | |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The value that is unique | |
![]() ![]() ![]() |
S | 0..1 | string | The manufacturer of the modality, related to tag(0008,0070) manufacturer |
![]() ![]() ![]() |
S | 0..1 | string | The serial number of the modality, which is the Device Serial Number |
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The manufacturer of the modality |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: manufacturer-name | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The model name of the modality |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Required Pattern: model-name | |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Describes the main modality type (CT, MG, etc.) Binding: Modality (required) |
![]() ![]() ![]() |
0..* | BackboneElement | Describes the Software Versions of the device, related to tag(0018,1020) Software Versions | |
![]() |
Path | Conformance | ValueSet | URI |
Device.type | required | Modalityhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html |
Key Elements View
Name | Flags | Card. | Type | Description & Constraints![]() |
---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created |
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored |
![]() ![]() ![]() |
1..* | Identifier | Instance identifier Slice: Unordered, Open by pattern:type | |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device Serial Number, related to tag(0018,1000) Device Serial Number |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Serial Number | |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() ![]() |
S | 1..1 | Identifier | Describes the AETitle of the modality irradiating the patient |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: application-entity | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Application Entity | |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device UID, related to tag(0018,1002) Device UID |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-uid | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device UID | |
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Required Pattern: urn:dicom:uid |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device ID, related to tag((0018,1003) Device ID |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following |
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-id | |
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device ID | |
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 |
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. |
![]() ![]() ![]() |
S | 0..1 | string | The manufacturer of the modality, related to tag(0008,0070) manufacturer |
![]() ![]() ![]() |
S | 0..1 | string | The serial number of the modality, which is the Device Serial Number |
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The manufacturer of the modality |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: manufacturer-name | |
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The model name of the modality |
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Describes the main modality type (CT, MG, etc.) Binding: Modality (required) |
![]() ![]() ![]() |
0..* | BackboneElement | Describes the Software Versions of the device, related to tag(0018,1020) Software Versions | |
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized |
![]() ![]() ![]() ![]() |
1..1 | string | The version text | |
![]() |
Path | Conformance | ValueSet / Code | URI |
Device.identifier:deviceSerialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:deviceSerialNumber.type | extensible | Pattern: SNO("Serial Number")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.identifier:aeTitle.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:aeTitle.type | extensible | Pattern: application-entity("Application Entity")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.identifier:deviceUID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:deviceUID.type | extensible | Pattern: device-uid("Device UID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.identifier:deviceID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | |
Device.identifier:deviceID.type | extensible | Pattern: device-id("Device ID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | |
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | |
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.deviceName:manufacturer.type | required | Pattern: manufacturer-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.deviceName:manufacturerModelName.type | required | Pattern: model-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | |
Device.type | required | Modalityhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html |
Snapshot View
Name | Flags | Card. | Type | Description & Constraints![]() | ||||
---|---|---|---|---|---|---|---|---|
![]() ![]() |
0..* | Device | Item used in healthcare | |||||
![]() ![]() ![]() |
Σ | 0..1 | id | Logical id of this artifact | ||||
![]() ![]() ![]() |
Σ | 0..1 | Meta | Metadata about the resource | ||||
![]() ![]() ![]() |
?!Σ | 0..1 | uri | A set of rules under which this content was created | ||||
![]() ![]() ![]() |
0..1 | code | Language of the resource content Binding: CommonLanguages (preferred): A human language.
| |||||
![]() ![]() ![]() |
0..1 | Narrative | Text summary of the resource, for human interpretation | |||||
![]() ![]() ![]() |
0..* | Resource | Contained, inline Resources | |||||
![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() |
?! | 0..* | Extension | Extensions that cannot be ignored | ||||
![]() ![]() ![]() |
1..* | Identifier | Instance identifier Slice: Unordered, Open by pattern:type | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device Serial Number, related to tag(0018,1000) Device Serial Number | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://terminology.hl7.org/CodeSystem/v2-0203 | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: SNO | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Serial Number | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() ![]() |
S | 1..1 | Identifier | Describes the AETitle of the modality irradiating the patient | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: application-entity | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Application Entity | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device UID, related to tag(0018,1002) Device UID | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-uid | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device UID | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Required Pattern: urn:dicom:uid | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() ![]() |
S | 0..1 | Identifier | Describes the Device ID, related to tag((0018,1003) Device ID | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..1 | code | usual | official | temp | secondary | old (If known) Binding: IdentifierUse (required): Identifies the purpose for this identifier, if known . | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | CodeableConcept | Description of identifier Binding: Identifier Type Codes (extensible): A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Required Pattern: At least the following | ||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
1..* | Coding | Code defined by a terminology system Fixed Value: (complex) | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | uri | Identity of the terminology system Fixed Value: http://hl7.org/fhir/uv/radiation-dose-summary/CodeSystem/dicom-identifier-type | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Version of the system - if relevant | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | code | Symbol in syntax defined by the system Fixed Value: device-id | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
1..1 | string | Representation defined by the system Fixed Value: Device ID | |||||
![]() ![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | boolean | If this coding was chosen directly by the user | |||||
![]() ![]() ![]() ![]() ![]() ![]() |
0..1 | string | Plain text representation of the concept | |||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | uri | The namespace for the identifier value Example General: http://www.acme.com/identifiers/patient | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 1..1 | string | The value that is unique Example General: 123456 | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Period | Time period when id is/was valid for use | ||||
![]() ![]() ![]() ![]() ![]() |
Σ | 0..1 | Reference(Organization) | Organization that issued id (may be just text) | ||||
![]() ![]() ![]() |
0..1 | Reference(DeviceDefinition) | The reference to the definition for the device | |||||
![]() ![]() ![]() |
Σ | 0..* | BackboneElement | Unique Device Identifier (UDI) Barcode string | ||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | Mandatory fixed portion of UDI | ||||
![]() ![]() ![]() ![]() |
0..1 | uri | UDI Issuing Organization | |||||
![]() ![]() ![]() ![]() |
0..1 | uri | Regional UDI authority | |||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | base64Binary | UDI Machine Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
Σ | 0..1 | string | UDI Human Readable Barcode String | ||||
![]() ![]() ![]() ![]() |
0..1 | code | barcode | rfid | manual + Binding: UDIEntryType (required): Codes to identify how UDI data was entered. | |||||
![]() ![]() ![]() |
?!Σ | 0..1 | code | active | inactive | entered-in-error | unknown Binding: FHIRDeviceStatus (required): The availability status of the device. | ||||
![]() ![]() ![]() |
0..* | CodeableConcept | online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off Binding: FHIRDeviceStatusReason (extensible): The availability status reason of the device. | |||||
![]() ![]() ![]() |
0..1 | string | The distinct identification string | |||||
![]() ![]() ![]() |
S | 0..1 | string | The manufacturer of the modality, related to tag(0008,0070) manufacturer | ||||
![]() ![]() ![]() |
0..1 | dateTime | Date when the device was made | |||||
![]() ![]() ![]() |
0..1 | dateTime | Date and time of expiry of this device (if applicable) | |||||
![]() ![]() ![]() |
0..1 | string | Lot number of manufacture | |||||
![]() ![]() ![]() |
S | 0..1 | string | The serial number of the modality, which is the Device Serial Number | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The name of the device as given by the manufacturer Slice: Unordered, Open by value:type | |||||
![]() ![]() ![]() ![]() |
Content/Rules for all slices | |||||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The manufacturer of the modality | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: manufacturer-name | |||||
![]() ![]() ![]() ![]() |
S | 0..1 | BackboneElement | The model name of the modality | ||||
![]() ![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() ![]() |
1..1 | string | The name of the device | |||||
![]() ![]() ![]() ![]() ![]() |
1..1 | code | udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other Binding: DeviceNameType (required): The type of name the device is referred by. Required Pattern: model-name | |||||
![]() ![]() ![]() |
0..1 | string | The model number for the device | |||||
![]() ![]() ![]() |
0..1 | string | The part number of the device | |||||
![]() ![]() ![]() |
S | 1..1 | CodeableConcept | Describes the main modality type (CT, MG, etc.) Binding: Modality (required) | ||||
![]() ![]() ![]() |
0..* | BackboneElement | The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | The standard that is used to operate and communicate | |||||
![]() ![]() ![]() ![]() |
0..1 | string | The version of the standard that is used to operate and communicate | |||||
![]() ![]() ![]() |
0..* | BackboneElement | Describes the Software Versions of the device, related to tag(0018,1020) Software Versions | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
0..1 | CodeableConcept | The type of the device version | |||||
![]() ![]() ![]() ![]() |
0..1 | Identifier | A single component of the device version | |||||
![]() ![]() ![]() ![]() |
1..1 | string | The version text | |||||
![]() ![]() ![]() |
0..* | BackboneElement | The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties | |||||
![]() ![]() ![]() ![]() |
0..1 | string | Unique id for inter-element referencing | |||||
![]() ![]() ![]() ![]() |
0..* | Extension | Additional content defined by implementations | |||||
![]() ![]() ![]() ![]() |
?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ||||
![]() ![]() ![]() ![]() |
1..1 | CodeableConcept | Code that specifies the property DeviceDefinitionPropetyCode (Extensible) | |||||
![]() ![]() ![]() ![]() |
0..* | Quantity | Property value as a quantity | |||||
![]() ![]() ![]() ![]() |
0..* | CodeableConcept | Property value as a code, e.g., NTP4 (synced to NTP) | |||||
![]() ![]() ![]() |
0..1 | Reference(Patient) | Patient to whom Device is affixed | |||||
![]() ![]() ![]() |
0..1 | Reference(Organization) | Organization responsible for device | |||||
![]() ![]() ![]() |
0..* | ContactPoint | Details for human/organization for support | |||||
![]() ![]() ![]() |
0..1 | Reference(Location) | Where the device is found | |||||
![]() ![]() ![]() |
0..1 | uri | Network address to contact device | |||||
![]() ![]() ![]() |
0..* | Annotation | Device notes and comments | |||||
![]() ![]() ![]() |
Σ | 0..* | CodeableConcept | Safety Characteristics of Device | ||||
![]() ![]() ![]() |
0..1 | Reference(Device) | The parent device | |||||
![]() |
Path | Conformance | ValueSet / Code | URI | |||
Device.language | preferred | CommonLanguages
http://hl7.org/fhir/ValueSet/languages from the FHIR Standard | ||||
Device.identifier:deviceSerialNumber.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:deviceSerialNumber.type | extensible | Pattern: SNO("Serial Number")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.identifier:aeTitle.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:aeTitle.type | extensible | Pattern: application-entity("Application Entity")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.identifier:deviceUID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:deviceUID.type | extensible | Pattern: device-uid("Device UID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.identifier:deviceID.use | required | IdentifierUsehttp://hl7.org/fhir/ValueSet/identifier-use|4.0.1 from the FHIR Standard | ||||
Device.identifier:deviceID.type | extensible | Pattern: device-id("Device ID")http://hl7.org/fhir/ValueSet/identifier-type from the FHIR Standard | ||||
Device.udiCarrier.entryType | required | UDIEntryTypehttp://hl7.org/fhir/ValueSet/udi-entry-type|4.0.1 from the FHIR Standard | ||||
Device.status | required | FHIRDeviceStatushttp://hl7.org/fhir/ValueSet/device-status|4.0.1 from the FHIR Standard | ||||
Device.statusReason | extensible | FHIRDeviceStatusReasonhttp://hl7.org/fhir/ValueSet/device-status-reason from the FHIR Standard | ||||
Device.deviceName.type | required | DeviceNameTypehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.deviceName:manufacturer.type | required | Pattern: manufacturer-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.deviceName:manufacturerModelName.type | required | Pattern: model-namehttp://hl7.org/fhir/ValueSet/device-nametype|4.0.1 from the FHIR Standard | ||||
Device.type | required | Modalityhttp://dicom.nema.org/medical/dicom/current/output/chtml/part16/sect_CID_33.html |
This structure is derived from Device
Summary
Mandatory: 5 elements(6 nested mandatory elements)
Must-Support: 9 elements
Slices
This structure defines the following Slices:
Other representations of profile: CSV, Excel, Schematron