Radiation Dose Summary for Diagnostic Procedures on FHIR
0.1.0 - ci-build International flag

Radiation Dose Summary for Diagnostic Procedures on FHIR, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 0.1.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-radiation-dose-summary-ig/ and changes regularly. See the Directory of published versions

Example Observation: RadiationDoseSummary-122

Generated Narrative: Observation 122

partOf: ImagingStudy: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.121.3.32.0.1.32; status = available; started = 2019-01-23 11:45:30+0000

status: Final

code: Radiation exposure and protection information [Description] Document Diagnostic imaging

subject: Pascale Dupont

focus: ImagingStudy: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.121.3.32.0.1.32; status = available; started = 2019-01-23 11:45:30+0000

effective: 2019-01-23 12:00:30+0000

performer: John Moore

value: Activity = 154 MBq (123-I)

component

code: Procedure reported

value: Radiopharmaceutical Administration

component

code: Administered activity

value: 154 MBq

component

code: Radiopharmaceuticals

value: Product containing ioflupane (123-I) (medicinal product)