QI-Core Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 7.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-qi-core/ and changes regularly. See the Directory of published versions
<DiagnosticReport xmlns="http://hl7.org/fhir">
<id value="example"/>
<text>
<status value="generated"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: DiagnosticReport example</b></p><a name="example"> </a><a name="hcexample"> </a><a name="example-en-US"> </a><h2><span title="Codes:{http://loinc.org 58410-2}">CBC panel - Blood by Automated count</span> (<span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0074 LAB}">Laboratory</span>) </h2><table class="grid"><tr><td>Subject</td><td>Jim Chalmers Male, DoB: 1974-12-25 ( Medical record number (use: usual, period: 2001-05-06 --> (ongoing)))</td></tr><tr><td>When For</td><td>2005-07-05</td></tr><tr><td>Reported</td><td>2005-07-06 11:45:33+1100</td></tr><tr><td>Performer</td><td> <a href="Organization-example.html">Organization Health Level Seven International</a></td></tr></table><p><b>Report Details</b></p><table class="grid"><tr><td><b>Code</b></td><td><b>Value</b></td><td><b>Flags</b></td><td><b>When For</b></td><td><b>Reported</b></td></tr><tr><td><a href="Observation-example.html"><span title="Codes:{http://loinc.org 30350-3}">Hemoglobin [Mass/volume] in Venous blood</span></a> (<span title="Codes:{http://snomed.info/sct 308046002}">Superficial forearm vein</span>)</td><td>7.2 g/dl<span style="background: LightGoldenRodYellow"> (Details: UCUM codeg/dL = 'g/dL')</span></td><td>Final, <span title="Codes:{http://terminology.hl7.org/CodeSystem/v2-0078 L}">Below low normal</span></td><td>2013-04-02 10:30:10+0100 --> 2013-04-05 10:30:10+0100</td><td>2013-04-03 15:30:10+0100</td></tr></table></div>
</text>
<status value="final"/>
<category>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0074"/>
<code value="LAB"/>
<display value="Laboratory"/>
</coding>
</category>
<code>
<coding>
<system value="http://loinc.org"/>
<code value="58410-2"/>
<display value="CBC panel - Blood by Automated count"/>
</coding>
</code>
<subject>🔗
<reference value="Patient/example"/>
<display value="Peter Chalmers"/>
</subject>
<effectiveDateTime value="2005-07-05"/>
<issued value="2005-07-06T11:45:33+11:00"/>
<performer>🔗
<reference value="Organization/example"/>
</performer>
<result>🔗
<reference value="Observation/example"/>
</result>
</DiagnosticReport>