Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-body-height' vs 'http://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fsc' |
Error | StructureDefinition.version | Values for version differ: '4.0.0' vs '1.0.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreBodyHeightProfile' vs 'FunctionalStatusCollection' |
Information | StructureDefinition.title | Values for title differ: 'US Core Body Height Profile' vs 'PACIO Functional Status Collection' |
Information | StructureDefinition.date | Values for date differ: '2020-11-17' vs '2021-11-03T18:56:23+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International - US Realm Steering Committee' vs 'HL7 Patient Care Work Group' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation' |
Warning | Observation | Elements differ in short:
'US Core Body Height Profile'
'Measurements and simple assertions' |
Warning | Observation | Elements differ in definition:
'Defines constraints on Observation to represent body height observations with a standard LOINC code and UCUM units of measure. This profile is derived from the US Core Vital Signs Profile.'
'Measurements and simple assertions made about a patient, device or other subject.' |
Warning | Observation.extension | Elements differ in short:
'Additional content defined by implementations'
'Extension' |
Warning | Observation.extension | Elements differ in definition:
'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.'
'An Extension' |
Warning | Observation.basedOn | Elements differ in short:
'Fulfills plan, proposal or order'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.partOf | Elements differ in short:
'Part of referenced event'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.status | Elements differ in short:
'registered | preliminary | final | amended +'
'Should have the value 'final' when all the observatons are complete and there are no further actions needed. Otherwise, another value from the value set may appropriately be used.' |
Error | Observation.status | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.category | Elements differ in short:
'Classification of type of observation'
'A second category code may be used along with the code “functioning”. For example, for assessment tool/survey instrument observations use “survey” as a second code.' |
Error | Observation.category | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.code | Elements differ in short:
'Body Height'
'For a Post-Acute Care structured assessment resource such as an instrument or screen, use a LOINC code to identify the instrument/screen name or panel/section title to indicate the kind of assessment.' |
Warning | Observation.code | Elements differ in definition:
'Coded Responses from C-CDA Vital Sign Results.'
'Describes what was observed. Sometimes this is called the observation 'name'.' |
Warning | Observation.code | Elements differ in requirements:
'5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
'Knowing what kind of observation is being made is essential to understanding the observation.' |
Error | Observation.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.subject | Elements differ in short:
'Who and/or what the observation is about'
'Should only reference a Patient resource.' |
Error | Observation.subject | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.focus | Elements differ in short:
'What the observation is about, when it is not about the subject of record'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.effective[x] | Elements differ in short:
'Often just a dateTime for Vital Signs'
'Clinical relevant time for an assessment such as functional assessments performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).' |
Warning | Observation.effective[x] | Elements differ in definition:
'Often just a dateTime for Vital Signs.'
'Clinical relevant time for an assessment such as functional assessments performed with structured evaluation tools is the time the evaluation occurs, i.e., when the clinician obtains the answers entered in the tool. However, the only timing available may be when then tool is completed by the clinician. That timing is generally documented as a point in time (dateTime).' |
Warning | Observation.effective[x] | Elements differ in comments:
'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing] datatype which allow the measurement to be tied to regular life events.'
'The use of effective[x] and dateTime versus Period is subject to implementer workflow and needs. In most situations, an observation is considered as a point in time, even if the assessment occurred over a period of time. Period is included in this implementation guide to provide additional flexibility for specific use cases. However, it is expected most observations will be recorded using DateTime. Furthermore, any retrieval of information should return the relevant if DateTime is requested, even if the original observation was recorded as a period. Some implementers may choose to use additional functions in there retrieves to 'normalize' intervals, as is done in Clinical Quality Language (CQL).' |
Error | Observation.effective[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.issued | Elements differ in short:
'Date/Time this version was made available'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.performer | Elements differ in short:
'Who is responsible for the observation'
'The person who performed the assessment. The preferred way to specify the performer is to use the PractitionerRole resource to provide both the practitioner and organization.' |
Warning | Observation.value[x] | Elements differ in short:
'Vital Signs Value'
'If used, should use the CodeableConcept datatype whenever possible to provide a suitable code to define the concept for the observation data. When capturing a collection of related observations, typically this field is not used. If the outcome of an assessment includes one or more summary scores, leave this field unused and use the 'hasMember' field to point to one or more Observation resources with each of which has a score provided in the 'value' field.' |
Warning | Observation.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.dataAbsentReason | Elements differ in short:
'Why the result is missing'
'Currently not used in FunctionalStatusCollection.' |
Error | Observation.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.interpretation | Elements differ in short:
'High, low, normal, etc.'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.bodySite | Elements differ in short:
'Observed body part'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.method | Elements differ in short:
'How it was done'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.specimen | Elements differ in short:
'Specimen used for this observation'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.device | Elements differ in short:
'(Measurement) Device'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.referenceRange | Elements differ in short:
'Provides guide for interpretation'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.hasMember | Elements differ in short:
'Used when reporting vital signs panel components'
'Each functional status observation in the collection.' |
Warning | Observation.hasMember | Elements differ in definition:
'Used when reporting vital signs panel components.'
'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' |
Error | Observation.hasMember | Elements differ in definition for mustSupport:
'false'
'true' |
Error | Observation.hasMember | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/us/pacio-fs/StructureDefinition/pacio-fs]]) |
Warning | Observation.derivedFrom | Elements differ in short:
'Related measurements the observation is made from'
'Should point back to the SDC QuestionnaireResponse that this resource is derived from.' |
Error | Observation.derivedFrom | Elements differ in definition for mustSupport:
'false'
'true' |
Error | Observation.derivedFrom | Type Mismatch:
Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
Reference([CanonicalType[http://hl7.org/fhir/uv/sdc/StructureDefinition/sdc-questionnaireresponse]]) |
Warning | Observation.component | Elements differ in short:
'Component observations'
'Currently not used in FunctionalStatusCollection.' |
Warning | Observation.component | Elements differ in definition:
'Used when reporting component observation such as systolic and diastolic blood pressure.'
'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' |
Error | Observation.component | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.code | Elements differ in definition for mustSupport:
'true'
'false' |
Warning | Observation.component.code | Elements differ in binding.description:
'The vital sign codes from the base FHIR and US Core Vital Signs.'
'Codes identifying names of simple observations.' |
Warning | Observation.component.value[x] | Elements differ in short:
'Vital Sign Component Value'
'Actual component result' |
Warning | Observation.component.value[x] | Elements differ in definition:
'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.'
'The information determined as a result of making the observation, if the information has a simple value.' |
Warning | Observation.component.value[x] | Elements differ in requirements:
'9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' |
Error | Observation.component.value[x] | Elements differ in definition for mustSupport:
'true'
'false' |
Error | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport:
'true'
'false' |