This is the set of resources that conform to both US Core Pulse Oximetry Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-pulse-oximetry) and ADI PtAuthored Care Experience Preference (http://hl7.org/fhir/us/pacio-adi/StructureDefinition/ADI-CareExperiencePreference).
Name | Flags | Card. | Type | Description & Constraints | ||||
---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | left: US Core Pulse Oximetry Profile; right: Measurements and simple assertions dom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated dom-5: If a resource is contained in another resource, it SHALL NOT have a security label dom-6: A resource should have narrative for robust management obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | |||||
meta | Σ | 0..1 | Meta | Metadata about the resource ele-1: All FHIR elements must have a @value or children | ||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created ele-1: All FHIR elements must have a @value or children | ||||
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
ele-1: All FHIR elements must have a @value or children | |||||
text | S | 1..1 | Narrative | Text summary of the resource, for human interpretation ele-1: All FHIR elements must have a @value or children | ||||
contained | 0..* | Resource | Contained, inline Resources | |||||
extension | 0..* | Extension | left: Additional content defined by implementations; right: Extension ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation ele-1: All FHIR elements must have a @value or children | ||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order ele-1: All FHIR elements must have a @value or children | ||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event ele-1: All FHIR elements must have a @value or children | ||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required): Codes providing the status of an observation. ele-1: All FHIR elements must have a @value or children | ||||
category | S | 1..* | CodeableConcept | Classification of type of observation Binding: ?? (preferred): Codes for high level observation categories. ele-1: All FHIR elements must have a @value or children | ||||
code | SΣ | 1..1 | CodeableConcept | left: Oxygen Saturation by Pulse Oximetry; right: Type of observation (code / type) Binding: ?? (extensible): Vital sign result types ele-1: All FHIR elements must have a @value or children | ||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
coding | SΣ | 2..* | Coding | Code defined by a terminology system ele-1: All FHIR elements must have a @value or children | ||||
text | SΣ | 0..1 | string | Plain text representation of the concept ele-1: All FHIR elements must have a @value or children | ||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile) | Who and/or what the observation is about ele-1: All FHIR elements must have a @value or children | ||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record ele-1: All FHIR elements must have a @value or children | ||||
encounter | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made ele-1: All FHIR elements must have a @value or children | ||||
effective[x] | SΣC | 1..1 | left: Often just a dateTime for Vital Signs; right: Clinically relevant time/time-period for observation ele-1: All FHIR elements must have a @value or children vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day | |||||
effectiveDateTime | dateTime S | |||||||
effectivePeriod | Period | |||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available ele-1: All FHIR elements must have a @value or children | ||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation ele-1: All FHIR elements must have a @value or children | ||||
value[x] | SΣ | 1..1 | left: Vital Signs Value; right: Actual result Binding: ?? (extensible): Common UCUM units for recording Vital Signs. ele-1: All FHIR elements must have a @value or children | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | S | 0..1 | CodeableConcept | Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. ele-1: All FHIR elements must have a @value or children | |||||
note | 0..* | Annotation | Comments about the observation ele-1: All FHIR elements must have a @value or children | |||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: ?? (example): Codes describing anatomical locations. May include laterality. ele-1: All FHIR elements must have a @value or children | |||||
method | 0..1 | CodeableConcept | How it was done Binding: ?? (example): Methods for simple observations. ele-1: All FHIR elements must have a @value or children | |||||
specimen | 0..1 | Reference(Specimen) | Specimen used for this observation ele-1: All FHIR elements must have a @value or children | |||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device ele-1: All FHIR elements must have a @value or children | |||||
referenceRange | C | 0..* | BackboneElement | Provides guide for interpretation ele-1: All FHIR elements must have a @value or children obs-3: Must have at least a low or a high or text | ||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
low | 0..1 | ?? | Low Range, if relevant ele-1: All FHIR elements must have a @value or children | |||||
high | 0..1 | ?? | High Range, if relevant ele-1: All FHIR elements must have a @value or children | |||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. ele-1: All FHIR elements must have a @value or children | |||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. ele-1: All FHIR elements must have a @value or children | |||||
age | 0..1 | Range | Applicable age range, if relevant ele-1: All FHIR elements must have a @value or children | |||||
text | 0..1 | string | Text based reference range in an observation ele-1: All FHIR elements must have a @value or children | |||||
hasMember | Σ | 0..* | left: Used when reporting vital signs panel components; right: Related resource that belongs to the Observation group ele-1: All FHIR elements must have a @value or children | |||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from ele-1: All FHIR elements must have a @value or children | ||||
component | SΣC | 0..* | BackboneElement | left: Used when reporting flow rates or oxygen concentration.; right: Component results ele-1: All FHIR elements must have a @value or children vs-3: If there is no a value a data absent reason must be present | ||||
extension | 0..* | Extension | Additional content defined by implementations ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | |||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized ele-1: All FHIR elements must have a @value or children ext-1: Must have either extensions or value[x], not both | ||||
code | SΣ | 1..1 | CodeableConcept | left: Coded vital sign result type; right: Type of component observation (code / type) Binding: ?? (extensible): Vital sign result types ele-1: All FHIR elements must have a @value or children | ||||
value[x] | SΣ | 0..1 | left: Vital Sign Component Value; right: Actual component result Binding: ?? (extensible): Common UCUM units for recording Vital Signs. ele-1: All FHIR elements must have a @value or children | |||||
valueQuantity | Quantity S | |||||||
valueCodeableConcept | CodeableConcept | |||||||
valueString | string | |||||||
valueBoolean | boolean | |||||||
valueInteger | integer | |||||||
valueRange | Range | |||||||
valueRatio | Ratio | |||||||
valueSampledData | SampledData | |||||||
valueTime | time | |||||||
valueDateTime | dateTime | |||||||
valuePeriod | Period | |||||||
dataAbsentReason | S | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. ele-1: All FHIR elements must have a @value or children | ||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. ele-1: All FHIR elements must have a @value or children | |||||
referenceRange | 0..* | Provides guide for interpretation of component result ele-1: All FHIR elements must have a @value or children | ||||||
Documentation for this format |