Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-blood-pressure vs http://hl7.org/fhir/us/mdi/StructureDefinition/Observation-personal-information-data-quality

Left:US Core Blood Pressure Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-blood-pressure)
Right:Observation - Personal Information Data Quality (http://hl7.org/fhir/us/mdi/StructureDefinition/Observation-personal-information-data-quality)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-blood-pressure' vs 'http://hl7.org/fhir/us/mdi/StructureDefinition/Observation-personal-information-data-quality'
ErrorStructureDefinition.versionValues for version differ: '7.0.0' vs '2.0.0-cibuild'
InformationStructureDefinition.nameValues for name differ: 'USCoreBloodPressureProfile' vs 'ObservationPersonalInformationDataQuality'
InformationStructureDefinition.titleValues for title differ: 'US Core Blood Pressure Profile' vs 'Observation - Personal Information Data Quality'
InformationStructureDefinition.dateValues for date differ: '2023-10-17' vs '2024-10-07T21:14:44+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International / Cross-Group Projects' vs 'HL7 International / Public Health'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signs' vs 'http://hl7.org/fhir/StructureDefinition/Observation'
InformationStructureDefinition.shortValues for short differ: 'US Core Blood Pressure Profile' vs 'Measurements and simple assertions'
InformationStructureDefinition.definitionValues for definition differ: 'The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient.' vs 'Measurements and simple assertions made about a patient, device or other subject.'
InformationStructureDefinition.requirementsValues for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).'
InformationStructureDefinition.commentValues for comment differ: 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below for guidance on referencing another Observation.' vs 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below for guidance on referencing another Observation.'
WarningObservation.statusElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.categoryElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.categoryElement minimum cardinalities differ: '1' vs '0'
InformationStructureDefinition.shortValues for short differ: 'Blood Pressure' vs 'Personal Information Data Quality Observation'
InformationStructureDefinition.definitionValues for definition differ: 'Coded Responses from C-CDA Vital Sign Results.' vs 'Describes what was observed. Sometimes this is called the observation 'name'.'
InformationStructureDefinition.requirementsValues for requirements differ: '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' vs 'Knowing what kind of observation is being made is essential to understanding the observation.'
WarningObservation.codeElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.subjectElements differ in definition for mustSupport: 'true' vs 'false'
InformationStructureDefinition.commentValues for comment differ: 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/extension-observation-focuscode.html).' vs 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/R4/extension-observation-focuscode.html).'
InformationObservation.focusElement minimum cardinalities differ: '0' vs '1'
InformationObservation.focusElement maximum cardinalities differ: '2147483647' vs '1'
InformationStructureDefinition.shortValues for short differ: 'Often just a dateTime for Vital Signs' vs 'Clinically relevant time/time-period for observation'
InformationStructureDefinition.definitionValues for definition differ: 'Often just a dateTime for Vital Signs.' vs 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.'
InformationStructureDefinition.commentValues for comment differ: 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/R4/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.'
WarningObservation.effective[x]Elements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.effective[x]Element minimum cardinalities differ: '1' vs '0'
InformationStructureDefinition.commentValues for comment differ: 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' vs 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/R4/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.'
InformationStructureDefinition.shortValues for short differ: 'Vital Signs Value' vs 'Personal information data quality review conclusion.'
InformationStructureDefinition.definitionValues for definition differ: 'Vital Signs value are typically recorded using the Quantity data type.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
InformationStructureDefinition.commentValues for comment differ: 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' vs 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.'
InformationStructureDefinition.requirementsValues for requirements differ: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.value[x]Element minimum cardinalities differ: '0' vs '1'
WarningObservation.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.noteElements differ in definition for mustSupport: 'false' vs 'true'
InformationStructureDefinition.commentValues for comment differ: 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/extension-bodysite.html).' vs 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/R4/extension-bodysite.html).'
InformationStructureDefinition.requirementsValues for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).'
InformationStructureDefinition.shortValues for short differ: 'Used when reporting vital signs panel components' vs 'Related resource that belongs to the Observation group'
InformationStructureDefinition.definitionValues for definition differ: 'Used when reporting vital signs panel components.' vs 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.'
InformationStructureDefinition.commentValues for comment differ: 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/questionnaireresponse.html) into a final score and represent the score as an Observation.' vs 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/R4/questionnaireresponse.html) into a final score and represent the score as an Observation.'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
InformationStructureDefinition.commentValues for comment differ: 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below.' vs 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below.'
InformationStructureDefinition.shortValues for short differ: 'Component observations' vs 'Component results'
InformationStructureDefinition.definitionValues for definition differ: 'Used when reporting component observation such as systolic and diastolic blood pressure.' vs 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.'
InformationStructureDefinition.commentValues for comment differ: 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/observation.html#notes) below.' vs 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/R4/observation.html#notes) below.'
WarningObservation.componentElements differ in definition for mustSupport: 'true' vs 'false'
InformationObservation.componentElement minimum cardinalities differ: '2' vs '0'
InformationStructureDefinition.requirementsValues for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).'
InformationStructureDefinition.shortValues for short differ: 'Coded vital sign result type' vs 'Type of component observation (code / type)'
WarningObservation.component.codeElements differ in definition for mustSupport: 'true' vs 'false'
InformationStructureDefinition.shortValues for short differ: 'Vital Sign Component Value' vs 'Actual component result'
InformationStructureDefinition.definitionValues for definition differ: 'Vital Signs value are typically recorded using the Quantity data type. For supporting observations such as cuff size could use other datatypes such as CodeableConcept.' vs 'The information determined as a result of making the observation, if the information has a simple value.'
InformationStructureDefinition.commentValues for comment differ: 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' vs 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.'
InformationStructureDefinition.requirementsValues for requirements differ: '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' vs 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'true' vs 'false'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'true' vs 'false'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-vital-signshttp://hl7.org/fhir/StructureDefinition/Observation
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons License
    • Removed the item 'Used by permission of HL7 International, all rights reserved Creative Commons License'
    .date2023-10-172024-10-07T21:14:44+00:00
    • Values Differ
    .descriptionUS Core Blood Pressure Profile inherits from the US Core Vital Signs Profile. This profile sets minimum expectations for the Observation resource to record, search, and fetch diastolic and systolic blood pressure observations with standard LOINC codes and UCUM units of measure. It specifies which *additional* core elements, extensions, vocabularies, and value sets **SHALL** be present in the resource and constrains how the elements are used. Providing the floor for standards development for specific use cases promotes interoperability and adoption.This Observation profile describes TBD.
    • Values Differ
    .experimentalfalse
    • Removed the item 'false'
    .fhirVersion4.0.1
      .jurisdiction
        ..jurisdiction[0]urn:iso:std:iso:3166#US
          .kindresource
            .nameUSCoreBloodPressureProfileObservationPersonalInformationDataQuality
            • Values Differ
            .publisherHL7 International / Cross-Group ProjectsHL7 International / Public Health
            • Values Differ
            .purpose
              .statusactive
                .titleUS Core Blood Pressure ProfileObservation - Personal Information Data Quality
                • Values Differ
                .typeObservation
                  .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-blood-pressurehttp://hl7.org/fhir/us/mdi/StructureDefinition/Observation-personal-information-data-quality
                  • Values Differ
                  .version7.0.02.0.0-cibuild
                  • Values Differ

                  Structure

                  NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.R TypeR Description & ConstraintsCommentsdoco
                  .. Observation C0..*USCoreVitalSignsProfileUS Core Blood Pressure Profile
                  obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
                  obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
                  vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
                  C0..*ObservationMeasurements and simple assertions
                  obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
                  obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
                    ... id Σ0..1idLogical id of this artifactΣ0..1idLogical id of this artifact
                      ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                        ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                          ... language 0..1codeLanguage of the resource content
                          Binding: ?? (preferred): A human language.

                          Additional BindingsPurpose
                          ??Max Binding
                          0..1codeLanguage of the resource content
                          Binding: ?? (preferred): A human language.

                          Additional BindingsPurpose
                          ??Max Binding
                            ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                              ... contained 0..*ResourceContained, inline Resources
                              0..*ResourceContained, inline Resources
                                ... extension 0..*ExtensionAdditional content defined by implementations
                                0..*ExtensionAdditional content defined by implementations
                                  ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                  ?!0..*ExtensionExtensions that cannot be ignored
                                    ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                    Σ0..*IdentifierBusiness Identifier for observation
                                      ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                      Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                        ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                        Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                          ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                          Binding: ?? (required)
                                          ?!Σ1..1coderegistered | preliminary | final | amended +
                                          Binding: ?? (required): Codes providing the status of an observation.

                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                          ... Slices for category S1..*CodeableConceptClassification of type of observation
                                          Slice: Unordered, Open by value:coding.code, value:coding.system
                                          Binding: ?? (preferred): Codes for high level observation categories.


                                          0..*CodeableConceptClassification of type of observation
                                          Binding: ?? (preferred): Codes for high level observation categories.


                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                          • Element minimum cardinalities differ: '1' vs '0'
                                          ... code SΣ1..1CodeableConceptBlood Pressure
                                          Binding: ?? (extensible): Vital sign result types


                                          Required Pattern: {"coding":[{"system":"http://loinc.org","code":"85354-9"}]}
                                          Σ1..1CodeableConceptPersonal Information Data Quality Observation
                                          Binding: ?? (example): Codes identifying names of simple observations.


                                          Required Pattern: {"coding":[{"system":"http://hl7.org/fhir/us/mdi/CodeSystem/CodeSystem-vr-codes","code":"PersonalInformationDataQuality"}]}
                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                          ... subject SΣ1..1Reference(US Core Patient Profile(5.0.1))Who and/or what the observation is aboutΣ1..1Reference(Decedent)Who and/or what the observation is about
                                          • Elements differ in definition for mustSupport: 'true' vs 'false'
                                          ... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                          Σ1..1Reference(Death Certificate)What the observation is about, when it is not about the subject of record
                                          • Element minimum cardinalities differ: '0' vs '1'
                                          • Element maximum cardinalities differ: '2147483647' vs '1'
                                          ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                            ... effective[x] SΣC1..1dateTime S, PeriodOften just a dateTime for Vital Signs
                                            vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
                                            Σ0..1dateTime, Period, Timing, instantClinically relevant time/time-period for observation
                                            • Elements differ in definition for mustSupport: 'true' vs 'false'
                                            • Element minimum cardinalities differ: '1' vs '0'
                                            ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                              ... performer Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                              Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                ... value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Signs Value
                                                Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                ΣC1..1CodeableConceptPersonal information data quality review conclusion.
                                                Binding: ?? (example)
                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                • Element minimum cardinalities differ: '0' vs '1'
                                                ... dataAbsentReason SC0..1CodeableConceptWhy the result is missing
                                                Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                C0..1CodeableConceptWhy the result is missing
                                                Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                0..*CodeableConceptHigh, low, normal, etc.
                                                Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                  ... note 0..*AnnotationComments about the observation
                                                  S0..*AnnotationComments about the observation
                                                  • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                  ... bodySite 0..1CodeableConceptObserved body part
                                                  Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                  0..1CodeableConceptObserved body part
                                                  Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                    ... method 0..1CodeableConceptHow it was done
                                                    Binding: ?? (example): Methods for simple observations.

                                                    0..1CodeableConceptHow it was done
                                                    Binding: ?? (example): Methods for simple observations.

                                                      ... specimen 0..1Reference(Specimen)Specimen used for this observation0..1Reference(Specimen)Specimen used for this observation
                                                        ... device 0..1Reference(Device | DeviceMetric)(Measurement) Device0..1Reference(Device | DeviceMetric)(Measurement) Device
                                                          ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                                          obs-3: Must have at least a low or a high or text
                                                          C0..*BackboneElementProvides guide for interpretation
                                                          obs-3: Must have at least a low or a high or text
                                                            .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                              .... extension 0..*ExtensionAdditional content defined by implementations
                                                              0..*ExtensionAdditional content defined by implementations
                                                                .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                  .... low C0..1??Low Range, if relevantC0..1??Low Range, if relevant
                                                                    .... high C0..1??High Range, if relevantC0..1??High Range, if relevant
                                                                      .... type 0..1CodeableConceptReference range qualifier
                                                                      Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                      0..1CodeableConceptReference range qualifier
                                                                      Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                        .... appliesTo 0..*CodeableConceptReference range population
                                                                        Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                        0..*CodeableConceptReference range population
                                                                        Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                          .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                            .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                              ... hasMember Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                              Σ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)Related resource that belongs to the Observation group
                                                                              • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]])
                                                                              ... derivedFrom Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                              Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)Related measurements the observation is made from
                                                                                ... Slices for component SΣC2..*BackboneElementComponent observations
                                                                                Slice: Unordered, Open by pattern:code
                                                                                vs-3: If there is no a value a data absent reason must be present
                                                                                Σ0..*BackboneElementComponent results
                                                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                • Element minimum cardinalities differ: '2' vs '0'
                                                                                .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                                  .... extension 0..*ExtensionAdditional content defined by implementations
                                                                                  0..*ExtensionAdditional content defined by implementations
                                                                                    .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                    ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                      .... code SΣ1..1CodeableConceptCoded vital sign result type
                                                                                      Binding: ?? (extensible): Vital sign result types

                                                                                      Σ1..1CodeableConceptType of component observation (code / type)
                                                                                      Binding: ?? (example): Codes identifying names of simple observations.

                                                                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                      .... value[x] SΣC0..1Quantity S, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Component Value
                                                                                      Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                                                      Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component result
                                                                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                      .... dataAbsentReason SC0..1CodeableConceptWhy the component result is missing
                                                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                      C0..1CodeableConceptWhy the component result is missing
                                                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                      .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                      0..*CodeableConceptHigh, low, normal, etc.
                                                                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                        .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                                        0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                                          doco Documentation for this format