minimal Common Oncology Data Elements (mCODE) Implementation Guide, published by HL7 International / Clinical Interoperability Council. This guide is not an authorized publication; it is the continuous build for version 4.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-mCODE-ig/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/mcode/ValueSet/mcode-teleradiotherapy-technique-vs | Version: 4.0.0-ballot | |||
Active as of 2024-10-30 | Maturity Level: 3 | Computable Name: TeleradiotherapyTechniqueVS | ||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.15.48.73 | ||||
Copyright/Legal: This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement |
Codes describing the techniques of teleradiotherapy (external beam) procedures.
References
Changes since version true:
The following rules apply to this value set:
Valid combinations of modality and technique are described in the modality and technique extension [RadiotherapyModalityAndTechnique].
Common Usage Name | Definition | SNOMED CT Fully Specified Name | SNOMED CT Concept ID |
---|---|---|---|
Two Dimensional Planning (2D) | Dose calculated without projection onto 3D imaging and delivered without 3D techniques. | Two dimensional external beam radiation therapy (procedure) | 1156526006 |
Three Dimensional Planning (3D) | Dose calculated with projection onto 3D imaging (e.g. CT or MR) delivered with either static aperture (Collimator, SRS Cone, Static MLC, blocks, etc) or non-IMRT/VMAT dynamic apertures (e.g. field-in-field, dynamic arc) using either single gantry angles or arcs. | Three dimensional external beam radiation therapy | 1162782007 |
Intensity Modulated Radiation Therapy (IMRT) | A technique of high-precision radiotherapy that uses computer control to deliver precise radiation doses that conform to a three-dimensional (3-D) shape by modulating the intensity of the radiation beam across the areas irradiated by each of the beams, with patterns designed under computer control to optimize the dose distribution according to a set of limits specified for target, organ at risk, and other structures. | Intensity modulated radiation therapy (procedure) | 441799006 |
Intraoperative Radiation Therapy (IORT) | A radiation treatment administered during surgery. | Radiotherapy - intraoperative control (procedure) | 168524008 |
Neutron Capture Therapy (NCT) | A technique where the patient is injected with a tumor-localizing drug containing a neutron absorber (boron-10), and then radiated with neutrons, which are captured, releasing high-energy alpha particles. | Neutron capture therapy (procedure) | 169317000 |
Particle Passive Scattering (PPS) | In proton or carbon ion beam therapy, a technique where the beam is spread out to larger dimension using a scattering device such as lead foil. | External beam radiation therapy using particle passive scattering technique (procedure) | 1156529004 |
Particle Spot Scanning (PSS) | In proton or carbon ion beam therapy, a technique where accelerated particles are focused into a small beam and then moved (scanned) over target regions in the patient. | External beam radiation therapy using particle spot scanning technique (procedure) | 1156528007 |
Volumetric Modulated Arc Therapy (VMAT) | A type of IMRT technique where the radiotherapy machine rotates around the patient, radiating the target in a complete three-dimensional manner with variable speed and/or dose rate. | Volumetric Modulated Arc Therapy (procedure) | 1156530009 |
Generated Narrative: ValueSet mcode-teleradiotherapy-technique-vs
This value set includes codes based on the following rules:
Generated Narrative: ValueSet
Expansion based on:
This value set contains 10 concepts
Code | System | Display |
441799006 | http://snomed.info/sct | Intensity modulated radiation therapy |
1156530009 | http://snomed.info/sct | VMAT - volumetric modulated arc therapy |
1162782007 | http://snomed.info/sct | Three dimensional external beam radiation therapy (procedure) |
1156526006 | http://snomed.info/sct | Two dimensional external beam radiation therapy (procedure) |
168524008 | http://snomed.info/sct | Radiotherapy - intraoperative control |
1163157007 | http://snomed.info/sct | FLASH radiotherapy |
169317000 | http://snomed.info/sct | Neutron capture therapy |
1156529004 | http://snomed.info/sct | External beam radiation therapy using particle passive scattering technique |
1156528007 | http://snomed.info/sct | Particle spot scanning external beam radiotherapy |
1204242009 | http://snomed.info/sct | External beam radiation therapy using particle scanning technique (procedure) |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |