minimal Common Oncology Data Elements (mCODE) Implementation Guide, published by HL7 International / Clinical Interoperability Council. This guide is not an authorized publication; it is the continuous build for version 4.0.0-ballot built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-mCODE-ig/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/mcode/ValueSet/mcode-radiotherapy-modality-vs | Version: 4.0.0-ballot | |||
Active as of 2024-10-30 | Maturity Level: 3 | Computable Name: RadiotherapyModalityVS | ||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.15.48.55 | ||||
Copyright/Legal: This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement |
Codes describing the modalities of external beam and brachytherapy radiation procedures, for use with radiotherapy summaries. This value set is the union of the teleradiotherapy and brachytherapy modality value sets.
References
Changes since version true:
Generated Narrative: ValueSet mcode-radiotherapy-modality-vs
This value set includes codes based on the following rules:
http://terminology.hl7.org/CodeSystem/v3-NullFlavor
Code | Display | Definition |
UNC | un-encoded | **Description:** The actual value has not yet been encoded within the approved value domain. **Example**: Original text or a local code has been specified but translation or encoding to the approved value set has not yet occurred due to limitations of the sending system. Original text has been captured for a PQ, but not attempt has been made to split the value and unit or to encode the unit in UCUM. **Usage Notes**: If it is known that it is not possible to encode the concept, OTH should be used instead. However, use of UNC does not necessarily guarantee the concept will be encodable, only that encoding has not been attempted. Data type properties such as original text and translations may be present when this null flavor is included. |
Generated Narrative: ValueSet
Expansion based on:
This value set contains 12 concepts
Code | System | Display | Definition |
10611004 | http://snomed.info/sct | Teleradiotherapy protons | |
45643008 | http://snomed.info/sct | Teleradiotherapy using electrons | |
80347004 | http://snomed.info/sct | Teleradiotherapy neutrons | |
1156505006 | http://snomed.info/sct | Teleradiotherapy using carbon ions | |
1156506007 | http://snomed.info/sct | Teleradiotherapy using photons | |
1156708005 | http://snomed.info/sct | LDR (low dose rate) brachytherapy temporary placement | |
169359004 | http://snomed.info/sct | Internal radiotherapy - permanent seeds | |
1156384006 | http://snomed.info/sct | Pulsed dose rate brachytherapy (procedure) | |
394902000 | http://snomed.info/sct | High dose brachytherapy (procedure) | |
438629002 | http://snomed.info/sct | High dose rate electronic brachytherapy (procedure) | |
440252007 | http://snomed.info/sct | Administration of radiopharmaceutical (procedure) | |
UNC | http://terminology.hl7.org/CodeSystem/v3-NullFlavor | un-encoded | Description: The actual value has not yet been encoded within the approved value domain. Example: Original text or a local code has been specified but translation or encoding to the approved value set has not yet occurred due to limitations of the sending system. Original text has been captured for a PQ, but not attempt has been made to split the value and unit or to encode the unit in UCUM. Usage Notes: If it is known that it is not possible to encode the concept, OTH should be used instead. However, use of UNC does not necessarily guarantee the concept will be encodable, only that encoding has not been attempted. Data type properties such as original text and translations may be present when this null flavor is included. |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |