Quality Measure Implementation Guide
1.0.0 - STU 1 International flag

Quality Measure Implementation Guide, published by HL7 International / Clinical Quality Information. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/fhir-cqm/ and changes regularly. See the Directory of published versions

: eCQM Update 2024 - Initial Draft - JSON Representation

Page standards status: Informative

Raw json | Download

{
  "resourceType" : "Library",
  "id" : "Manifest-Initial-Draft",
  "meta" : {
    "profile" : [
      🔗 "http://hl7.org/fhir/uv/crmi/StructureDefinition/crmi-manifestlibrary"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n  <table class=\"narrative-table\">\n    <tbody>\n<tr>\n\n\n<th colspan=\"2\" scope=\"row\" class=\"row-header\">Metadata</th>\n\n\n</tr>\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Title</th>\n\n\n<td class=\"content-container\">eCQM Update 2024 - Initial Draft</td>\n</tr>\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Version</th>\n\n\n<td class=\"content-container\">1.0.0-initial</td>\n</tr>\n\n\n\n\n\n\n\n  \n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Identifier</th>\n\n\n<td class=\"content-container\">eCQM Update 2024</td>\n</tr>\n\n\n  \n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Identifier</th>\n\n\n<td class=\"content-container\">urn:oid:2.16.840.1.113883.4.642.40.61.28.27</td>\n</tr>\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Status</th>\n\n\n<td class=\"content-container\">Draft</td>\n</tr>\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Experimental</th>\n\n\n<td class=\"content-container\">true</td>\n</tr>\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Jurisdiction</th>\n\n\n<td class=\"content-container\"><span title=\"Codes:{http://unstats.un.org/unsd/methods/m49/m49.htm 001}\">Global (Whole world)</span></td>\n</tr>\n\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Steward (Publisher)</th>\n\n\n<td class=\"content-container\">HL7 International / Clinical Quality Information</td>\n</tr>\n\n\n\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Description</th>\n\n\n<td class=\"content-container\"><div><p>This library is an example initial draft of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for an example set of CMS measures.</p>\n</div></td>\n</tr>\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Purpose</th>\n\n\n<td class=\"content-container\"><div><p>This library is defined to illustrate a Version Manifest in initial draft status, as it would look at the beginning of an eCQM Annual Update cycle, established on August 1st, 2023. The latest available version of code systems used at that time is specified to provide stability for value set expansion during the authoring phase. Terminology.HL7.org, in particular, was version 5.2.0 at the time, and FHIR code system versions are chosen from that release.</p>\n</div></td>\n</tr>\n\n\n\n\n\n\n<tr>\n\n\n<th scope=\"row\" class=\"row-header\">Type</th>\n\n\n<td class=\"content-container\"><span title=\"Codes:{http://terminology.hl7.org/CodeSystem/library-type asset-collection}\">Asset Collection</span></td>\n</tr>\n\n\n\n\n<tr>\n  <th colspan=\"2\" scope=\"row\" class=\"row-header\">Generated using version 0.4.9 of the sample-content-ig Liquid templates</th>\n</tr>\n\n    </tbody>\n  </table>\n</div>"
  },
  "contained" : [
    {
      "resourceType" : "Parameters",
      "id" : "exp-params",
      "parameter" : [
        {
          "name" : "system-version",
          "valueCanonical" : "http://snomed.info/sct|http://snomed.info/sct/731000124108/version/20230901"
        },
        {
          "name" : "system-version",
          "valueCanonical" : "http://loinc.org|2.74"
        },
        {
          "name" : "activeOnly",
          "valueBoolean" : true
        },
        {
          "name" : "includeDraft",
          "valueBoolean" : true
        }
      ]
    }
  ],
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/cqf-expansionParameters",
      "valueReference" : {
        "reference" : "#exp-params"
      }
    },
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "cqi"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/cqm/Library/Manifest-Initial-Draft",
  "identifier" : [
    {
      "use" : "official",
      "system" : "http://example.org/fhir/cqi/ecqm/Library/Identifier",
      "value" : "eCQM Update 2024"
    },
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.4.642.40.61.28.27"
    }
  ],
  "version" : "1.0.0-initial",
  "name" : "ECQMUpdate2024InitialDraft",
  "title" : "eCQM Update 2024 - Initial Draft",
  "status" : "draft",
  "experimental" : true,
  "type" : {
    "coding" : [
      {
        "system" : "http://terminology.hl7.org/CodeSystem/library-type",
        "code" : "asset-collection"
      }
    ]
  },
  "date" : "2023-08-01",
  "publisher" : "HL7 International / Clinical Quality Information",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/cqi"
        }
      ]
    }
  ],
  "description" : "This library is an example initial draft of a version manifest (also referred to as an expansion profile) that specifies expansion rules for a set of value sets used for an example set of CMS measures.",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "purpose" : "This library is defined to illustrate a Version Manifest in initial draft status, as it would look at the beginning of an eCQM Annual Update cycle, established on August 1st, 2023. The latest available version of code systems used at that time is specified to provide stability for value set expansion during the authoring phase. Terminology.HL7.org, in particular, was version 5.2.0 at the time, and FHIR code system versions are chosen from that release."
}