Validation Results for adverseeventclinicalcare

Generated Thu May 25 12:37:49 UTC 2023, FHIR version 5.0.0 for hl7.fhir.uv.adverseeventclinicalcare#0.2.0 (canonical = http://hl7.org/fhir/uv/adverseeventclinicalcare (history)). See Errors Only

Quality Checks
Publisher Version:IG Publisher Version: v1.3.12
Publication Code:adverseeventclinicalcare . PackageId = hl7.fhir.uv.adverseeventclinicalcare, Canonical = http://hl7.org/fhir/uv/adverseeventclinicalcare
Realm Check for UV:
  • n/a
Publication Request:
  • The file package-list.json should not exist in the root folder
  • This IG has never been published
  • This IG has never been published, so the version should start with '0.' or include a patch version e.g. '-ballot'
  • No publication request found
Supressed Messages:1 Suppressed Issue
Dependency Checks:
PackageVersionFHIRCanonicalWeb BaseComment
.. hl7.fhir.uv.adverseeventclinicalcare0.2.0R5http://hl7.org/fhir/uv/adverseeventclinicalcare
... hl7.terminology.r55.0.0 OR5http://terminology.hl7.orghttp://terminology.hl7.org/5.0.0Latest Release is 5.1.0
... hl7.fhir.uv.extensions.r51.0.0 MR5http://hl7.org/fhir/extensionshttp://hl7.org/fhir/extensions/1.0.0
Templates: fhir.base.template#current
Dependent IGs:no references
Global Profiles:(none declared)
HTA Analysis:no Non-HL7 references found
R5 Dependencies:(none)
Modifier Extensions:(none)
Previous Version Comparison: Unable to compare with previous version: Unable to find version history at http://hl7.org/fhir/uv/adverseeventclinicalcare (Problem #1 with package-list.json at http://hl7.org/fhir/uv/adverseeventclinicalcare: Invalid HTTP response 404 from http://hl7.org/fhir/uv/adverseeventclinicalcare/package-list.json?nocache=1685018254318 (Not Found) (content in /tmp/http-log/fhir-http-2.log))
IPA Comparison: n/a
Summary: errors = 0, warn = 1, info = 1, broken links = 0
FilenameErrorsWarningsHints
Build Errors000
/scratch/ig-build-temp-HSXFS9/repo/fsh-generated/resources/StructureDefinition-AdverseEvent-clinical-care000
/scratch/ig-build-temp-HSXFS9/repo/input/examples/adverseevent-clinicalcareexample1stage1000
/scratch/ig-build-temp-HSXFS9/repo/input/examples/adverseevent-clinicalcareexample1stage2000
/scratch/ig-build-temp-HSXFS9/repo/input/examples/adverseevent-clinicalcareexample2mom000
/scratch/ig-build-temp-HSXFS9/repo/input/examples/adverseevent-clinicalcareexample2patient000
/scratch/ig-build-temp-HSXFS9/repo/input/examples/adverseevent-clinicalcareexample2phlebotomist000
/scratch/ig-build-temp-HSXFS9/repo/input/examples/adverseevent-heartrateobservation001
/scratch/ig-build-temp-HSXFS9/repo/input/hl7-fhir-ae-care-ig010

n/a Show Validation Information


fsh-generated/resources/StructureDefinition-AdverseEvent-clinical-care.json Show Validation Information (1)


input/examples/adverseevent-clinicalcareexample1stage1.xml Show Validation Information (1)


input/examples/adverseevent-clinicalcareexample1stage2.xml Show Validation Information (1)


input/examples/adverseevent-clinicalcareexample2mom.xml Show Validation Information (1)


input/examples/adverseevent-clinicalcareexample2patient.xml Show Validation Information (1)


input/examples/adverseevent-clinicalcareexample2phlebotomist.xml Show Validation Information (1)


input/examples/adverseevent-heartrateobservation.xml Show Validation Information (1)

PathSeverityMessage
Observation.referenceRange[0].type (l60/c8)informationNone of the codings provided are in the value set 'Observation Reference Range Meaning Codes' (http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0), and a coding is recommended to come from this value set) (codes = http://snomed.info/sct#128974000)

input/hl7-fhir-ae-care-ig.xml Show Validation Information (0)

PathSeverityMessage
ImplementationGuide (l1/c16848)warningRule cnl-0: 'Name should be usable as an identifier for the module by machine processing applications such as code generation' Failed

Suppressed Messages (Warnings, hints, broken links)

Inherited valueset binding from the R5 snapshot3 but will resolve when R5 is published

Errors sorted by type


Terminology_TX_NoValid_3_CC

input/examples/adverseevent-heartrateobservation.xmlNone of the codings provided are in the value set 'Observation Reference Range Meaning Codes' (http://hl7.org/fhir/ValueSet/referencerange-meaning|5.0.0), and a coding is recommended to come from this value set) (codes = http://snomed.info/sct#128974000)