DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
<ImagingStudy xmlns="http://hl7.org/fhir">
<id value="measurement-report-evidence-sequence-imaging-study"/>
<language value="en"/>
<text>
<status value="generated"/>
<div xml:lang="en" xmlns="http://www.w3.org/1999/xhtml" lang="en"><pre>
{
"0020000D": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995" ] },
"0040A375": { "vr": "SQ", "Value": [ {
"0020000D": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995" ] },
"00081115": { "vr": "SQ", "Value": [ {
"0020000E": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995.1" ] },
"00081199": { "vr": "SQ", "Value": [ {
"00081150": { "vr": "UI", "Value": [ "1.2.840.10008.5.1.4.1.1.2" ] },
"00081155": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995.1.1" ] }
} ] }
},
{
"0020000D": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995" ] },
"00081115": { "vr": "SQ", "Value": [ {
"0020000E": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995.2" ] },
"00081199": { "vr": "SQ", "Value": [ {
"00081150": { "vr": "UI", "Value": [ "1.2.840.10008.5.1.4.1.1.2" ] },
"00081155": { "vr": "UI", "Value": [ "1.2.840.113747.20080222.83311413144566317081790268995.2.1" ] }
} ]
}
</pre></div>
</text>
<identifier>
<system value="urn:dicom:uid"/>
<value
value="urn:oid:1.2.840.113747.20080222.83311413144566317081790268995"/>
</identifier>
<status value="available"/>
<modality>
<coding>
<code value="CT"/>
</coding>
</modality>
<subject>🔗
<reference value="Patient/measurement-report-patient"/>
</subject>
<basedOn>🔗
<reference value="ServiceRequest/measurement-report-service-request"/>
</basedOn>
<numberOfSeries value="2"/>
<numberOfInstances value="2"/>
<series>
<uid value="1.2.840.113747.20080222.83311413144566317081790268995.1"/>
<number value="1"/>
<modality>
<coding>
<code value="CT"/>
</coding>
</modality>
<numberOfInstances value="1"/>
<instance>
<uid value="1.2.840.113747.20080222.83311413144566317081790268995.1.1"/>
<sopClass>
<code value="CTImageStorage"/>
</sopClass>
<number value="1"/>
</instance>
</series>
<series>
<uid value="1.2.840.113747.20080222.83311413144566317081790268995.2"/>
<number value="2"/>
<modality>
<coding>
<code value="CT"/>
</coding>
</modality>
<numberOfInstances value="1"/>
<instance>
<uid value="1.2.840.113747.20080222.83311413144566317081790268995.2.1"/>
<sopClass>
<code value="CTImageStorage"/>
</sopClass>
<number value="1"/>
</instance>
</series>
</ImagingStudy>