DICOM® SR to FHIR Resource Mapping IG
1.0.0 - STU1 Ballot International flag

DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: Example-Observation-ImagingQualitativeEvaluation-002 - XML Representation

Raw xml | Download


<Observation xmlns="http://hl7.org/fhir">
  <id value="qualitative-evaluation-002"/>
  <meta>
    <profile
             value="http://hl7.org/fhir/uv/dicom-sr/StructureDefinition/imaging-qualitative-evaluation"/>
  </meta>
  <text>
    <status value="generated"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: Observation qualitative-evaluation-002</b></p><a name="qualitative-evaluation-002"> </a><a name="hcqualitative-evaluation-002"> </a><a name="qualitative-evaluation-002-en-US"> </a><p><b>basedOn</b>: <a href="ServiceRequest-measurement-report-service-request.html">ServiceRequest: identifier = Accession ID: ACSN-235813; status = active; intent = order</a></p><p><b>partOf</b>: <a href="ImagingStudy-measurement-report-imaging-study.html">ImagingStudy: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995; status = available</a></p><p><b>status</b>: Final</p><p><b>category</b>: <span title="Codes:{http://terminology.hl7.org/CodeSystem/umls C0034375}">Qualitative Evaluations</span></p><p><b>code</b>: <span title="Codes:{http://radlex.org RID36042}">malignant neoplasm</span></p><p><b>subject</b>: <a href="Patient-measurement-report-patient.html">Anonymous Patient (no stated gender), DoB Unknown ( Medical Record Number: PID-12345)</a></p><p><b>focus</b>: </p><ul><li><a href="ImagingSelection-measurement-report-referenced-segment.html">ImagingSelection Referenced Segment</a></li><li><a href="BodyStructure-measurement-report-tracking-identifier.html">BodyStructure: identifier = Tracking Identifier: Nodule 1,Tracking Unique Identifier: DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995.100</a></li></ul><p><b>effective</b>: 2024-07-24 08:23:42+0000</p><p><b>issued</b>: 2024-07-24 08:23:42+0000</p><p><b>performer</b>: <a href="Practitioner-measurement-report-practitioner.html">Practitioner EXAMPLE RADIOLOGIST </a></p><p><b>value</b>: <span title="Codes:{http://cancerimagingarchive.net 905}">5 out of 5 (Highly Suspicious for Cancer)</span></p><p><b>bodyStructure</b>: <a href="BodyStructure-measurement-report-finding-site.html">BodyStructure</a></p><p><b>device</b>: <a href="Device-measurement-report-general-equipment.html">Device: identifier = Universal Device Identifier; displayName = Example Imaging Measurement Device; manufacturer = Example Device Manufacturer</a></p></div>
  </text>
  <basedOn>🔗 
    <reference value="ServiceRequest/measurement-report-service-request"/>
  </basedOn>
  <partOf>🔗 
    <reference value="ImagingStudy/measurement-report-imaging-study"/>
  </partOf>
  <status value="final"/>
  <category>
    <coding>
      <system value="http://terminology.hl7.org/CodeSystem/umls"/>
      <code value="C0034375"/>
      <display value="Qualitative Evaluations"/>
    </coding>
  </category>
  <code>
    <coding>
      <system value="http://radlex.org"/>
      <code value="RID36042"/>
    </coding>
  </code>
  <subject>🔗 
    <reference value="Patient/measurement-report-patient"/>
  </subject>
  <focus>🔗 
    <reference
               value="ImagingSelection/measurement-report-referenced-segment"/>
  </focus>
  <focus>🔗 
    <reference value="BodyStructure/measurement-report-tracking-identifier"/>
  </focus>
  <effectiveDateTime value="2024-07-24T08:23:42+00:00"/>
  <issued value="2024-07-24T08:23:42+00:00"/>
  <performer>🔗 
    <reference value="Practitioner/measurement-report-practitioner"/>
  </performer>
  <valueCodeableConcept>
    <coding>
      <system value="http://cancerimagingarchive.net"/>
      <code value="905"/>
      <display value="5 out of 5 (Highly Suspicious for Cancer)"/>
    </coding>
  </valueCodeableConcept>
  <bodyStructure>🔗 
    <reference value="BodyStructure/measurement-report-finding-site"/>
  </bodyStructure>
  <device>🔗 
    <reference value="Device/measurement-report-general-equipment"/>
  </device>
</Observation>