DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions
{
"resourceType" : "Observation",
"id" : "imaging-measurement-001",
"meta" : {
"profile" : [
🔗 "http://hl7.org/fhir/uv/dicom-sr/StructureDefinition/imaging-measurement"
]
},
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Observation imaging-measurement-001</b></p><a name=\"imaging-measurement-001\"> </a><a name=\"hcimaging-measurement-001\"> </a><a name=\"imaging-measurement-001-en-US\"> </a><p><b>basedOn</b>: <a href=\"ServiceRequest-measurement-report-service-request.html\">ServiceRequest: identifier = Accession ID: ACSN-235813; status = active; intent = order</a></p><p><b>partOf</b>: <a href=\"ImagingStudy-measurement-report-imaging-study.html\">ImagingStudy: identifier = urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995; status = available</a></p><p><b>status</b>: Final</p><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 118565006}\">Volume</span></p><p><b>subject</b>: <a href=\"Patient-measurement-report-patient.html\">Anonymous Patient (no stated gender), DoB Unknown ( Medical Record Number: PID-12345)</a></p><p><b>focus</b>: </p><ul><li><a href=\"ImagingSelection-measurement-report-referenced-segment.html\">ImagingSelection Referenced Segment</a></li><li><a href=\"BodyStructure-measurement-report-tracking-identifier.html\">BodyStructure: identifier = Tracking Identifier: Nodule 1,Tracking Unique Identifier: DICOM Unique Id#urn:oid:1.2.840.113747.20080222.83311413144566317081790268995.100</a></li></ul><p><b>effective</b>: 2024-07-24 08:23:42+0000</p><p><b>issued</b>: 2024-07-24 08:23:42+0000</p><p><b>performer</b>: <a href=\"Practitioner-measurement-report-practitioner.html\">Practitioner EXAMPLE RADIOLOGIST </a></p><p><b>value</b>: 6705.54990898997 cubic millimeter<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM codemm3 = 'mm3')</span></p><p><b>bodyStructure</b>: <a href=\"BodyStructure-measurement-report-finding-site.html\">BodyStructure</a></p><p><b>device</b>: <a href=\"Device-measurement-report-algorithm.html\">Device: displayName = pylidc</a></p></div>"
},
"basedOn" : [
{
🔗 "reference" : "ServiceRequest/measurement-report-service-request"
}
],
"partOf" : [
{
🔗 "reference" : "ImagingStudy/measurement-report-imaging-study"
}
],
"status" : "final",
"code" : {
"coding" : [
{
"system" : "http://snomed.info/sct",
"code" : "118565006",
"display" : "Volume"
}
]
},
"subject" : {
🔗 "reference" : "Patient/measurement-report-patient"
},
"focus" : [
{
🔗 "reference" : "ImagingSelection/measurement-report-referenced-segment"
},
{
🔗 "reference" : "BodyStructure/measurement-report-tracking-identifier"
}
],
"effectiveDateTime" : "2024-07-24T08:23:42+00:00",
"issued" : "2024-07-24T08:23:42+00:00",
"performer" : [
{
🔗 "reference" : "Practitioner/measurement-report-practitioner"
}
],
"valueQuantity" : {
"value" : 6705.54990898997,
"unit" : "cubic millimeter",
"system" : "http://unitsofmeasure.org",
"code" : "mm3"
},
"bodyStructure" : {
🔗 "reference" : "BodyStructure/measurement-report-finding-site"
},
"device" : {
🔗 "reference" : "Device/measurement-report-algorithm"
}
}