DICOM® SR to FHIR Resource Mapping IG
1.0.0 - STU1 Ballot International flag

DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: ConceptMap - DICOM Imaging Measurements Container to FHIR Mapping - JSON Representation

Active as of 2024-09-23

Raw json | Download

{
  "resourceType" : "ConceptMap",
  "id" : "dicom-imaging-measurements-container-to-fhir",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap dicom-imaging-measurements-container-to-fhir</b></p><a name=\"dicom-imaging-measurements-container-to-fhir\"> </a><a name=\"hcdicom-imaging-measurements-container-to-fhir\"> </a><a name=\"dicom-imaging-measurements-container-to-fhir-en-US\"> </a><p>Mapping from DICOM-Imaging-Measurements-Container to <a href=\"http://hl7.org/fhir/R5/bundle.html\">Bundle</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>TID4019 (Algorithm Identification)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>device (observation.device)</td><td>Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device.</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>125007 (Measurement Group)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>ImagingMeasurementGroup</td><td>Each Measurement Group container will be used to create a FHIR ImagingMeasurementGroup Observation.</td></tr><tr><td>126001 (Derived Imaging Measurements)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>DerivedImagingMeasurements</td><td>Each child of the the Derived Imaging Measurements container will be used to create a FHIR DerivedImagingMeasurement Observation.</td></tr><tr><td>C0034375 (Qualitative Evaluations)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>ImagingQualitativeEvaluation</td><td>Select children of the Imaging Qualitative Evaluations container will be used to create a FHIR ImagingQualitativeEvaluation Observation.</td></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "ii"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-imaging-measurements-container-to-fhir",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.4.642.40.39.18.5"
    }
  ],
  "version" : "1.0.0",
  "name" : "DICOMImagingMeasurementsContainerToFHIRMapping",
  "title" : "ConceptMap - DICOM Imaging Measurements Container to FHIR Mapping",
  "status" : "active",
  "experimental" : false,
  "date" : "2024-09-23T13:34:34+00:00",
  "publisher" : "HL7 International / Imaging Integration",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "HL7 International / Imaging Integration",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "Jonathan Whitby",
      "telecom" : [
        {
          "system" : "email",
          "value" : "jonathan.whitby@mi.medical.canon"
        },
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "Christopher Lindop",
      "telecom" : [
        {
          "system" : "email",
          "value" : "Christopher.Lindop@ge.com"
        },
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    }
  ],
  "description" : "Mapping between DICOM® Document IE and FHIR Resources",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "sourceScopeUri" : "DICOM-Imaging-Measurements-Container",
  "targetScopeUri" : "Bundle",
  "group" : [
    {
      "element" : [
        {
          "code" : "TID4019",
          "display" : "Algorithm Identification",
          "target" : [
            {
              "code" : "device",
              "display" : "observation.device",
              "relationship" : "equivalent",
              "comment" : "Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device."
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "125007",
          "display" : "Measurement Group",
          "target" : [
            {
              "code" : "ImagingMeasurementGroup",
              "display" : "ImagingMeasurementGroup",
              "relationship" : "equivalent",
              "comment" : "Each Measurement Group container will be used to create a FHIR ImagingMeasurementGroup Observation."
            }
          ]
        },
        {
          "code" : "126001",
          "display" : "Derived Imaging Measurements",
          "target" : [
            {
              "code" : "DerivedImagingMeasurements",
              "display" : "DerivedImagingMeasurements",
              "relationship" : "equivalent",
              "comment" : "Each child of the the Derived Imaging Measurements container will be used to create a FHIR DerivedImagingMeasurement Observation."
            }
          ]
        },
        {
          "code" : "C0034375",
          "display" : "Qualitative Evaluations",
          "target" : [
            {
              "code" : "ImagingQualitativeEvaluation",
              "display" : "ImagingQualitativeEvaluation",
              "relationship" : "equivalent",
              "comment" : "Select children of the Imaging Qualitative Evaluations container will be used to create a FHIR ImagingQualitativeEvaluation Observation."
            }
          ]
        }
      ]
    }
  ]
}