DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-imaging-measurements-container-to-fhir | Version: 1.0.0 | |||
Active as of 2024-09-23 | Computable Name: DICOMImagingMeasurementsContainerToFHIRMapping | |||
Other Identifiers: OID:2.16.840.1.113883.4.642.40.39.18.5 |
Mapping between DICOM® Document IE and FHIR Resources
Generated Narrative: ConceptMap dicom-imaging-measurements-container-to-fhir
Mapping from DICOM-Imaging-Measurements-Container to Bundle
Group 1 Mapping from unspecified code system
to unspecified code system
Source Code | Relationship | Target Code | Comment |
TID4019 (Algorithm Identification) | is equivalent to | device (observation.device) | Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device. |
Group 2 Mapping from unspecified code system
to unspecified code system
Source Code | Relationship | Target Code | Comment |
125007 (Measurement Group) | is equivalent to | ImagingMeasurementGroup | Each Measurement Group container will be used to create a FHIR ImagingMeasurementGroup Observation. |
126001 (Derived Imaging Measurements) | is equivalent to | DerivedImagingMeasurements | Each child of the the Derived Imaging Measurements container will be used to create a FHIR DerivedImagingMeasurement Observation. |
C0034375 (Qualitative Evaluations) | is equivalent to | ImagingQualitativeEvaluation | Select children of the Imaging Qualitative Evaluations container will be used to create a FHIR ImagingQualitativeEvaluation Observation. |