DICOM® SR to FHIR Resource Mapping IG
1.0.0 - STU1 Ballot International flag

DICOM® SR to FHIR Resource Mapping IG, published by HL7 International / Imaging Integration. This guide is not an authorized publication; it is the continuous build for version 1.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/dicom-sr/ and changes regularly. See the Directory of published versions

: ConceptMap - DICOM Imaging Measurement Group to FHIR Mapping - JSON Representation

Active as of 2024-09-23

Raw json | Download

{
  "resourceType" : "ConceptMap",
  "id" : "dicom-imaging-measurement-group-to-fhir",
  "text" : {
    "status" : "generated",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: ConceptMap dicom-imaging-measurement-group-to-fhir</b></p><a name=\"dicom-imaging-measurement-group-to-fhir\"> </a><a name=\"hcdicom-imaging-measurement-group-to-fhir\"> </a><a name=\"dicom-imaging-measurement-group-to-fhir-en-US\"> </a><p>Mapping from DICOM-Imaging-Measurement-Group to <a href=\"http://hl7.org/fhir/R5/bundle.html\">Bundle</a></p><br/><p><b>Group 1 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"3\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>IdentifierType</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">112039</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Tracking Identifier</td><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">identifier</td><td style=\"border-left-width: 0px\">BodyStructureTrackingIdentifiers.identifier</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">identifier</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus.identifier</td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">112040</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Tracking Unique Identifier</td><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">identifier</td><td style=\"border-left-width: 0px\">BodyStructureTrackingIdentifiers.identifier</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">identifier</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus.identifier</td></tr></table><hr/><p><b>Group 2 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>276214006 (Finding Category)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>code (ImagingMeasurementGroup.code)</td></tr></table><hr/><p><b>Group 3 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>121071 (Finding)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>valueCodingableConcept (ImagingMeasurementGroup.valueCodingableConcept)</td></tr></table><hr/><p><b>Group 4 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"3\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>ValueType</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">111030</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Image Region</td><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelection2dImageRegion</td><td style=\"border-left-width: 0px\">ImagingSelection2dImageRegion</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none; border-bottom-style: none\"/><td style=\"border-left-width: 0px; border-top-style: none; border-bottom-style: none\"/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelection3dImageRegion</td><td style=\"border-left-width: 0px\">ImagingSelection3dImageRegion</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 5 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">121214</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Referenced Segmentation Frame</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionReferencedSegmentationFrame</td><td style=\"border-left-width: 0px\">ImagingSelectionReferencedSegmentationFrame</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 6 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">130488</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Region in Space</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionRegionInSpace</td><td style=\"border-left-width: 0px\">ImagingSelectionRegionInSpace</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 7 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">121200</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Illustration of ROI</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionIllustrationOfROI</td><td style=\"border-left-width: 0px\">ImagingSelectionIllustrationOfROI</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 8 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">130401</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Visual explanation</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionVisualExplanation</td><td style=\"border-left-width: 0px\">ImagingSelectionVisualExplanation</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 9 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">126100</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Real World Value Map used for measurement</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionRealWorldValueMap</td><td style=\"border-left-width: 0px\">ImagingSelectionRealWorldValueMap</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 10 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">121191</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Referenced Segment</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionReferencedSegment</td><td style=\"border-left-width: 0px\">ImagingSelectionReferencedSegment</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 11 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">121231</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Volume Surface</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingSelectionVolumeSurface</td><td style=\"border-left-width: 0px\">ImagingSelectionVolumeSurface</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">focus</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.focus</td></tr></table><hr/><p><b>Group 12 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td></tr><tr><td>370129005 (Measurement Method)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>method (ImagingMeasurementGroup.method)</td></tr></table><hr/><p><b>Group 13 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"2\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td/><td colspan=\"2\"><b>Codes</b> from </td></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">363698007</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Finding Site</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">BodyStructureFindingSite</td><td style=\"border-left-width: 0px\">BodyStructureFindingSite</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">bodyStructure</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.bodyStructure</td></tr></table><hr/><p><b>Group 14 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td><b>Source Code</b></td><td><b>Relationship</b></td><td><b>Target Code</b></td><td><b>Comment</b></td></tr><tr><td>TID4019 (Algorithm Identification)</td><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td>device (ImagingMeasurementGroup.device)</td><td>Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device.</td></tr></table><hr/><p><b>Group 15 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"3\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>ValueType</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td><td/></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">C0034375</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Qualitative Evaluations</td><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingMeasurement</td><td style=\"border-left-width: 0px\">ImagingMeasurement</td><td>Select children of the Imaging Measurement Group container will be used to create a FHIR ImagingMeasurement Observation.</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">hasMember</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.hasMember</td><td/></tr></table><hr/><p><b>Group 16 </b>Mapping from <code>unspecified code system</code> to <code>unspecified code system</code></p><table class=\"grid\"><tr><td colspan=\"3\"><b>Source Concept Details</b></td><td><b>Relationship</b></td><td colspan=\"2\"><b>Target Concept Details</b></td><td><b>Comment</b></td><td colspan=\"2\"><b>Properties</b></td></tr><tr><td colspan=\"2\"><b>Codes</b> from </td><td><b>ValueType</b></td><td/><td colspan=\"2\"><b>Codes</b> from </td><td/></tr><tr><td style=\"border-right-width: 0px; border-bottom-style: none\">C0034375</td><td style=\"border-left-width: 0px; border-bottom-style: none\">Qualitative Evaluations</td><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">ImagingQualitativeEvaluation</td><td style=\"border-left-width: 0px\">ImagingQualitativeEvaluation</td><td>Select children of the Imaging Measurement Group container will be used to create a FHIR ImagingQualitativeEvaluation Observation.</td></tr><tr><td style=\"border-right-width: 0px; border-top-style: none\"/><td style=\"border-top-style: none; border-left-width: 0px\"/><td/><td><a href=\"http://hl7.org/fhir/R5/codesystem-concept-map-relationship.html#equivalent\" title=\"equivalent\">is equivalent to</a></td><td style=\"border-right-width: 0px\">hasMember</td><td style=\"border-left-width: 0px\">ImagingMeasurementGroup.hasMember</td><td/></tr></table></div>"
  },
  "extension" : [
    {
      "url" : "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg",
      "valueCode" : "ii"
    }
  ],
  "url" : "http://hl7.org/fhir/uv/dicom-sr/ConceptMap/dicom-imaging-measurement-group-to-fhir",
  "identifier" : [
    {
      "system" : "urn:ietf:rfc:3986",
      "value" : "urn:oid:2.16.840.1.113883.4.642.40.39.18.3"
    }
  ],
  "version" : "1.0.0",
  "name" : "DICOMImagingMeasurementGroupToFHIRMapping",
  "title" : "ConceptMap - DICOM Imaging Measurement Group to FHIR Mapping",
  "status" : "active",
  "experimental" : false,
  "date" : "2024-09-23T13:34:34+00:00",
  "publisher" : "HL7 International / Imaging Integration",
  "contact" : [
    {
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "HL7 International / Imaging Integration",
      "telecom" : [
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "Jonathan Whitby",
      "telecom" : [
        {
          "system" : "email",
          "value" : "jonathan.whitby@mi.medical.canon"
        },
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    },
    {
      "name" : "Christopher Lindop",
      "telecom" : [
        {
          "system" : "email",
          "value" : "Christopher.Lindop@ge.com"
        },
        {
          "system" : "url",
          "value" : "http://www.hl7.org/Special/committees/imagemgt"
        }
      ]
    }
  ],
  "description" : "Mapping between DICOM® Imaging Measurement Group and FHIR Resources",
  "jurisdiction" : [
    {
      "coding" : [
        {
          "system" : "http://unstats.un.org/unsd/methods/m49/m49.htm",
          "code" : "001"
        }
      ]
    }
  ],
  "additionalAttribute" : [
    {
      "code" : "IdentifierType",
      "uri" : "http://dicom.nema.org/resources/ontology/DCM",
      "description" : "DICOM® Controlled Terminology",
      "type" : "Coding"
    },
    {
      "code" : "ValueType",
      "uri" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
      "description" : "DICOM® Value Type",
      "type" : "Coding"
    }
  ],
  "sourceScopeUri" : "DICOM-Imaging-Measurement-Group",
  "targetScopeUri" : "Bundle",
  "group" : [
    {
      "element" : [
        {
          "code" : "112039",
          "display" : "Tracking Identifier",
          "target" : [
            {
              "code" : "identifier",
              "display" : "BodyStructureTrackingIdentifiers.identifier",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "IdentifierType",
                  "valueCoding" : {
                    "system" : "http://dicom.nema.org/resources/ontology/DCM",
                    "code" : "112039"
                  }
                }
              ]
            },
            {
              "code" : "identifier",
              "display" : "ImagingMeasurementGroup.focus.identifier",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "IdentifierType",
                  "valueCoding" : {
                    "system" : "http://dicom.nema.org/resources/ontology/DCM",
                    "code" : "112039"
                  }
                }
              ]
            }
          ]
        },
        {
          "code" : "112040",
          "display" : "Tracking Unique Identifier",
          "target" : [
            {
              "code" : "identifier",
              "display" : "BodyStructureTrackingIdentifiers.identifier",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "IdentifierType",
                  "valueCoding" : {
                    "system" : "http://dicom.nema.org/resources/ontology/DCM",
                    "code" : "112040"
                  }
                }
              ]
            },
            {
              "code" : "identifier",
              "display" : "ImagingMeasurementGroup.focus.identifier",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "IdentifierType",
                  "valueCoding" : {
                    "system" : "http://dicom.nema.org/resources/ontology/DCM",
                    "code" : "112040"
                  }
                }
              ]
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "276214006",
          "display" : "Finding Category",
          "target" : [
            {
              "code" : "code",
              "display" : "ImagingMeasurementGroup.code",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "121071",
          "display" : "Finding",
          "target" : [
            {
              "code" : "valueCodingableConcept",
              "display" : "ImagingMeasurementGroup.valueCodingableConcept",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "111030",
          "display" : "Image Region",
          "target" : [
            {
              "code" : "ImagingSelection2dImageRegion",
              "display" : "ImagingSelection2dImageRegion",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "scoord"
                  }
                }
              ]
            },
            {
              "code" : "ImagingSelection3dImageRegion",
              "display" : "ImagingSelection3dImageRegion",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "scoord3d"
                  }
                }
              ]
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "121214",
          "display" : "Referenced Segmentation Frame",
          "target" : [
            {
              "code" : "ImagingSelectionReferencedSegmentationFrame",
              "display" : "ImagingSelectionReferencedSegmentationFrame",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "130488",
          "display" : "Region in Space",
          "target" : [
            {
              "code" : "ImagingSelectionRegionInSpace",
              "display" : "ImagingSelectionRegionInSpace",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "121200",
          "display" : "Illustration of ROI",
          "target" : [
            {
              "code" : "ImagingSelectionIllustrationOfROI",
              "display" : "ImagingSelectionIllustrationOfROI",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "130401",
          "display" : "Visual explanation",
          "target" : [
            {
              "code" : "ImagingSelectionVisualExplanation",
              "display" : "ImagingSelectionVisualExplanation",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "126100",
          "display" : "Real World Value Map used for measurement",
          "target" : [
            {
              "code" : "ImagingSelectionRealWorldValueMap",
              "display" : "ImagingSelectionRealWorldValueMap",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "121191",
          "display" : "Referenced Segment",
          "target" : [
            {
              "code" : "ImagingSelectionReferencedSegment",
              "display" : "ImagingSelectionReferencedSegment",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "121231",
          "display" : "Volume Surface",
          "target" : [
            {
              "code" : "ImagingSelectionVolumeSurface",
              "display" : "ImagingSelectionVolumeSurface",
              "relationship" : "equivalent"
            },
            {
              "code" : "focus",
              "display" : "ImagingMeasurementGroup.focus",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "370129005",
          "display" : "Measurement Method",
          "target" : [
            {
              "code" : "method",
              "display" : "ImagingMeasurementGroup.method",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "363698007",
          "display" : "Finding Site",
          "target" : [
            {
              "code" : "BodyStructureFindingSite",
              "display" : "BodyStructureFindingSite",
              "relationship" : "equivalent"
            },
            {
              "code" : "bodyStructure",
              "display" : "ImagingMeasurementGroup.bodyStructure",
              "relationship" : "equivalent"
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "TID4019",
          "display" : "Algorithm Identification",
          "target" : [
            {
              "code" : "device",
              "display" : "ImagingMeasurementGroup.device",
              "relationship" : "equivalent",
              "comment" : "Content from the Algorithm Identification template will be used to create a FHIR AlgorithmIdentification Device."
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "C0034375",
          "display" : "Qualitative Evaluations",
          "target" : [
            {
              "code" : "ImagingMeasurement",
              "display" : "ImagingMeasurement",
              "relationship" : "equivalent",
              "comment" : "Select children of the Imaging Measurement Group container will be used to create a FHIR ImagingMeasurement Observation.",
              "dependsOn" : [
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "num"
                  }
                }
              ]
            },
            {
              "code" : "hasMember",
              "display" : "ImagingMeasurementGroup.hasMember",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "num"
                  }
                }
              ]
            }
          ]
        }
      ]
    },
    {
      "element" : [
        {
          "code" : "C0034375",
          "display" : "Qualitative Evaluations",
          "target" : [
            {
              "code" : "ImagingQualitativeEvaluation",
              "display" : "ImagingQualitativeEvaluation",
              "relationship" : "equivalent",
              "comment" : "Select children of the Imaging Measurement Group container will be used to create a FHIR ImagingQualitativeEvaluation Observation.",
              "dependsOn" : [
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "text"
                  }
                },
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "code"
                  }
                }
              ]
            },
            {
              "code" : "hasMember",
              "display" : "ImagingMeasurementGroup.hasMember",
              "relationship" : "equivalent",
              "dependsOn" : [
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "text"
                  }
                },
                {
                  "attribute" : "ValueType",
                  "valueCoding" : {
                    "system" : "http://hl7.org/fhir/uv/dicom-sr/CodeSystem/dicom-value-type",
                    "code" : "code"
                  }
                }
              ]
            }
          ]
        }
      ]
    }
  ]
}