| Error | ValueSet.url | Values for url differ: 'http://hl7.org/fhir/ValueSet/device-kind' vs 'http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs' |
| Error | ValueSet.version | Values for version differ: '4.0.1' vs '2.0.0' |
| Information | ValueSet.name | Values for name differ: 'FHIRDeviceTypes' vs 'BrachytherapyDeviceTypeVS' |
| Information | ValueSet.title | Values for title differ: 'FHIR Device Types' vs 'Brachytherapy Device Type Value Set' |
| Information | ValueSet.status | Values for status differ: 'draft' vs 'active' |
| Information | ValueSet.date | Values for date differ: '2019-11-01T09:29:23+11:00' vs '2026-02-11T00:55:08+00:00' |
| Information | ValueSet.publisher | Values for publisher differ: 'HL7 Orders and Observations Workgroup' vs 'HL7 International / Cross-Group Projects' |
| Information | ValueSet.copyright | Values for copyright differ: 'This resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org' vs 'This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement' |
| Information | ValueSet.jurisdiction | Added the item 'urn:iso:std:iso:3166#US' |
| Error | ValueSet.compose.include[0] | Code 1254768007 added |
| Error | ValueSet.compose.include[0] | Code 1254767002 added |
| Error | ValueSet.compose.include[0] | Code 1254766006 added |
| Error | ValueSet.compose.include[0] | Code 767049008 added |
| Name | Value | Comments | |
|---|---|---|---|
compose.inactive | |||
compose.lockedDate | |||
copyright | This resource includes content from SNOMED Clinical Terms® (SNOMED CT®) which is copyright of the International Health Terminology Standards Development Organisation (IHTSDO). Implementers of these specifications must have the appropriate SNOMED CT Affiliate license - for more information contact http://www.snomed.org/snomed-ct/get-snomed-ct or info@snomed.org | This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement |
|
date | 2019-11-01T09:29:23+11:00 | 2026-02-11T00:55:08+00:00 |
|
description | Codes used to identify medical devices. Includes concepts from SNOMED CT (http://www.snomed.org/) where concept is-a 49062001 (Device) and is provided as a suggestive example. | The type of radioactive seed used in brachytherapy |
|
experimental | false | ||
immutable | |||
jurisdiction | |||
![]() jurisdiction[0] | urn:iso:std:iso:3166#US |
| |
name | FHIRDeviceTypes | BrachytherapyDeviceTypeVS |
|
publisher | HL7 Orders and Observations Workgroup | HL7 International / Cross-Group Projects |
|
purpose | |||
status | draft | active |
|
title | FHIR Device Types | Brachytherapy Device Type Value Set |
|
url | http://hl7.org/fhir/ValueSet/device-kind | http://hl7.org/fhir/us/codex-radiation-therapy/ValueSet/codexrt-brachytherapy-device-type-vs |
|
version | 4.0.1 | 2.0.0 |
|
| Item | Property | Value | Comments | ||
|---|---|---|---|---|---|
include | http://snomed.info/sct | ||||
![]() Concept | 1254768007 | Version: Radioactive seed embedded in mesh (physical object) |
| ||
![]() Concept | 1254767002 | Version: Stranded radioactive seed (physical object) |
| ||
![]() Concept | 1254766006 | Version: Loose radioactive seed (physical object) |
| ||
![]() Concept | 767049008 | Version: Radioactive seed, device (physical object) |
| ||
Unable to generate expansion - see errors