CodeX Radiation Therapy
2.0.0 - STU2 United States of America flag

CodeX Radiation Therapy, published by HL7 International / Cross-Group Projects. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/codex-radiation-therapy/ and changes regularly. See the Directory of published versions

: RadiotherapyTreatedPhase-103-RightBreastTang - JSON Representation

Raw json | Download

{
  "resourceType" : "Procedure",
  "id" : "RadiotherapyTreatedPhase-103-RightBreastTang",
  "meta" : {
    "versionId" : "1233456",
    "lastUpdated" : "2020-10-28T13:22:17+01:00",
    "profile" : [
      🔗 "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-treated-phase"
    ]
  },
  "text" : {
    "status" : "extensions",
    "div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: Procedure RadiotherapyTreatedPhase-103-RightBreastTang</b></p><a name=\"RadiotherapyTreatedPhase-103-RightBreastTang\"> </a><a name=\"hcRadiotherapyTreatedPhase-103-RightBreastTang\"> </a><a name=\"RadiotherapyTreatedPhase-103-RightBreastTang-en-US\"> </a><div style=\"display: inline-block; background-color: #d9e0e7; padding: 6px; margin: 4px; border: 1px solid #8da1b4; border-radius: 5px; line-height: 60%\"><p style=\"margin-bottom: 0px\">version: 1233456; Last updated: 2020-10-28 13:22:17+0100</p><p style=\"margin-bottom: 0px\">Profile: <a href=\"StructureDefinition-codexrt-radiotherapy-treated-phase.html\">Radiotherapy Treated Phase</a></p></div><blockquote><p><b>Radiotherapy Modality And Technique Extension</b></p><ul><li>http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality: <span title=\"Codes:{http://snomed.info/sct 1156506007}\">External beam radiation therapy using photons (procedure)</span></li><li>http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique: <span title=\"Codes:{http://snomed.info/sct 1162782007}\">Three dimensional external beam radiation therapy (procedure)</span></li></ul></blockquote><p><b>Number of Delivered Fractions</b>: 25</p><blockquote><p><b>Radiotherapy Dose Delivered To Volume Extension</b></p><ul><li>volume: <a href=\"BodyStructure-RadiotherapyVolume-103-RightBreast.html\">BodyStructure: identifier = http://varian.com/fhir/identifier/radiotherapyDoseReferenceId#Right Breast\u00a0(use:\u00a0usual,\u00a0),urn:dicom:uid#DICOM Unique Id#urn:oid:1.2.246.352.71.842418.2121.20150602151.103\u00a0(use:\u00a0official,\u00a0); morphology = Planning target volume (observable entity); location = Breast structure (body structure); locationQualifier = Right (qualifier value),Entire (qualifier value)</a></li><li>totalDoseDelivered: 5000 cGy<span style=\"background: LightGoldenRodYellow\"> (Details: UCUM  codecGy = 'cGy')</span></li></ul></blockquote><p><b>identifier</b>: <code>http://varian.com/fhir/identifier/radiotherapyPhaseId</code>/Right Breast Tangents\u00a0(use:\u00a0usual,\u00a0), <a href=\"http://terminology.hl7.org/5.5.0/NamingSystem-dui.html\" title=\"An OID issued under DICOM OID rules. DICOM OIDs are represented as plain OIDs, with a prefix of &quot;urn:oid:&quot;. See https://www.dicomstandard.org/\">DICOM Unique Id</a>/urn:oid:2.16.124.113543.1154777499.30246.19789.558.101\u00a0(use:\u00a0official,\u00a0)</p><p><b>basedOn</b>: <a href=\"ServiceRequest-RadiotherapyPhasePrescription-103-RTTD-RightBreastTang.html\">ServiceRequest Radiotherapy treatment phase (regime/therapy)</a></p><p><b>partOf</b>: <a href=\"Procedure-RadiotherapyCourseSummary-101-RTTD-BilateralBreast.html\">Procedure Radiotherapy course of treatment</a></p><p><b>status</b>: Completed</p><p><b>category</b>: <span title=\"Codes:{http://snomed.info/sct 1287742003}\">Radiotherapy (procedure)</span></p><p><b>code</b>: <span title=\"Codes:{http://snomed.info/sct 1222565005}\">Radiotherapy treatment phase (regime/therapy)</span></p><p><b>subject</b>: <a href=\"Patient-Patient-101.html\">Alice BilateralBreast  Female, DoB: 1973-07-25 ( Medical Record Number: 101101101\u00a0(use:\u00a0usual,\u00a0))</a></p><p><b>performed</b>: 2020-10-27 13:15:17+0100 --&gt; 2020-10-28 13:21:17+0100</p><p><b>bodySite</b>: <span title=\"Codes:{http://snomed.info/sct 76752008}\">Breast structure (body structure)</span></p></div>"
  },
  "extension" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality",
          "valueCodeableConcept" : {
            "coding" : [
              {
                "system" : "http://snomed.info/sct",
                "code" : "1156506007",
                "display" : "External beam radiation therapy using photons (procedure)"
              }
            ]
          }
        },
        {
          "url" : "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-technique",
          "valueCodeableConcept" : {
            "coding" : [
              {
                "system" : "http://snomed.info/sct",
                "code" : "1162782007",
                "display" : "Three dimensional external beam radiation therapy (procedure)"
              }
            ]
          }
        }
      ],
      "url" : "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-modality-and-technique"
    },
    {
      "url" : "http://hl7.org/fhir/us/codex-radiation-therapy/StructureDefinition/codexrt-radiotherapy-fractions-delivered",
      "valueUnsignedInt" : 25
    },
    {
      "extension" : [
        {
          "url" : "volume",
          "valueReference" : {
            🔗 "reference" : "BodyStructure/RadiotherapyVolume-103-RightBreast"
          }
        },
        {
          "url" : "totalDoseDelivered",
          "valueQuantity" : {
            "value" : 5000,
            "system" : "http://unitsofmeasure.org",
            "code" : "cGy"
          }
        }
      ],
      "url" : "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-radiotherapy-dose-delivered-to-volume"
    }
  ],
  "identifier" : [
    {
      "use" : "usual",
      "system" : "http://varian.com/fhir/identifier/radiotherapyPhaseId",
      "value" : "Right Breast Tangents"
    },
    {
      "use" : "official",
      "system" : "urn:dicom:uid",
      "value" : "urn:oid:2.16.124.113543.1154777499.30246.19789.558.101"
    }
  ],
  "basedOn" : [
    {
      🔗 "reference" : "ServiceRequest/RadiotherapyPhasePrescription-103-RTTD-RightBreastTang"
    }
  ],
  "partOf" : [
    {
      🔗 "reference" : "Procedure/RadiotherapyCourseSummary-101-RTTD-BilateralBreast"
    }
  ],
  "status" : "completed",
  "category" : {
    "coding" : [
      {
        "system" : "http://snomed.info/sct",
        "code" : "1287742003",
        "display" : "Radiotherapy (procedure)"
      }
    ]
  },
  "code" : {
    "coding" : [
      {
        "system" : "http://snomed.info/sct",
        "code" : "1222565005",
        "display" : "Radiotherapy treatment phase (regime/therapy)"
      }
    ]
  },
  "subject" : {
    🔗 "reference" : "Patient/Patient-101"
  },
  "performedPeriod" : {
    "start" : "2020-10-27T13:15:17+01:00",
    "end" : "2020-10-28T13:21:17+01:00"
  },
  "bodySite" : [
    {
      "extension" : [
        {
          "url" : "http://hl7.org/fhir/us/mcode/StructureDefinition/mcode-laterality-qualifier",
          "valueCodeableConcept" : {
            "coding" : [
              {
                "system" : "http://snomed.info/sct",
                "code" : "24028007",
                "display" : "Right (qualifier value)"
              }
            ]
          }
        }
      ],
      "coding" : [
        {
          "system" : "http://snomed.info/sct",
          "code" : "76752008",
          "display" : "Breast structure (body structure)"
        }
      ]
    }
  ]
}