Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions

Requirements: PIM.1.1 General Information (Function)

Official URL: http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-PIM.1.1 Version: 2.0.1
Standards status: Informative Computable Name: PIM_1_1_General_Information
Criteria N:
PIM.1.1#01 SHALL

The system SHALL include in its product description the main functionality, the intended use, the intended (target) audience, and the potential use of the user's personal data by the system.

PIM.1.1#02 SHALL

The system SHALL provide screen shots that accurately depict the screens of the current version of the product.

PIM.1.1#03 SHALL

The system SHALL provide product information before it is used by the consumer, to help the consumer decide whether the system is suitable.

PIM.1.1#04 SHOULD

The system SHOULD clearly state in its product description the human languages it supports.

PIM.1.1#05 SHOULD

The system SHOULD provide information about the publisher (persons or organizations) and SHOULD provide mechanisms for communicating with the publisher.

PIM.1.1#06 SHOULD

The system SHOULD disclose its sources of funding and any possible conflicts of interest, such as use of the system incentivizing the user to buy products or services from the publisher.

PIM.1.1#07 SHALL conditional

IF the system uses AI functionality THEN the system SHALL state in its product description whether it uses AI functionality, what that functionality does, what data it uses, and whether AI output is used to inform health-related information, recommendations, or decisions.

PIM.1.1#08 SHALL conditional

IF the system uses an external AI service THEN the system SHALL state in its product description the limitations of its AI functionality, including the populations, conditions, or contexts for which the AI function was not evaluated.

PIM.1.1#09 SHOULD conditional

IF the system uses AI functionality THEN the system SHOULD disclose the provider or organization accountable for the AI-enabled feature and provide a mechanism to contact that organization about safety, privacy, or performance concerns.