Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions
| Page standards status: Informative |
<Requirements xmlns="http://hl7.org/fhir">
<id value="CMHAFFR2-PDS.2"/>
<meta>
<profile
value="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"/>
</meta>
<text>
<status value="extensions"/>
<div xmlns="http://www.w3.org/1999/xhtml"><p><b style="color: maroon">Exception parsing generated Narrative (see /tmp/liquid-01c02e84-1d06-49f2-903f-0acc9f683e44.html): unable to parse character reference ' Infrastructure, The
Mobile Threat Catalogue (USA) https://nccoe.nist.gov/sites/default/files/library/mtc-nistir-8144-draft.pdf (context and background
information)
https://pages.nist.gov/mobile-threat-catalogue/application.html#vulnerable-applications (actual catalog of threats, specifically the “Vulnerable
Application” category, which is the part ofthe threat catalog closest to cMHAFF)
• Open Web Application Security Project (OWASP) Top 10 Mobile Security Risks:
https://www.owasp.org/index.php/Mobile_Top_10_2016-Top_10 This is focused on appdevelopers, so most of it is pertinent to
cMHAFF, and for each risk, there are suggested mitigations.
• OWASP Secure Coding Practices Quick Reference Guide: https://owasp.org/www-project-secure-coding-practices-quick-
reference-guide/ - This provides resources for developers that can assist in implementing secure coding practices. It is
recommended that developers adopt secure coding practices so that applications are developed with an emphasis on security vs
having to apply security measures to protect the application.
Example:
While later sections in this standard include specific security and privacy controls to be applied to consumer mobile health apps, all products addressing
health issues, regardless of their type, must be subjected to an overall risk analysis. This risk analysis may uncover the need for additional security controls
over-and-above the conformance statements included in this document. As such, a risk analysis provides an additional layer of considerations such that
conformance statements are not misused as a simple checklist in which it is assumed all security risks have been addressed if an app is in compliance
with the conformance statements in this standard. For an app/product, the risk analysis should be conducted for the target environment(s) where the app
will actually be used by consumers. Because of the diversity of consumers, such a risk analysis is wider ranging and more challenging than a risk analysis
for the development organization’s own environment.'' (last text = ' ' at line 45 column 53</b></p></div>
</text>
<extension
url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
<valueCode value="mobile"/>
</extension>
<url value="http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-PDS.2"/>
<version value="2.0.1"/>
<name value="PDS_2_Product_Risk_Assessment_and_Mitigation"/>
<title value="PDS.2 Product Risk Assessment and Mitigation (Function)"/>
<status value="active"/>
<date value="2026-11-18T11:24:54+00:00"/>
<publisher value="HL7 International / Mobile Health"/>
<contact>
<telecom>
<system value="url"/>
<value value="http://www.hl7.org/Special/committees/mobile"/>
</telecom>
</contact>
<description
value="This category deals with process steps for risk assessment and mitigation for those
who are developing a new app, or an upgrade to an app, prior to its being deployed to
consumers."/>
<jurisdiction>
<coding>
<system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
<code value="001"/>
<display value="World"/>
</coding>
</jurisdiction>
<purpose
value="Degrees of risk should be assessed and mitigated according to the intended use
of the app. In general, risk management should manage security, privacy, safety, and other
types of risks such as potential app failure scenarios, events that could lead to undesirable
outcomes, probability and severity of risk, and mitigations or resolutions. One size does not fit
all. For example, if apps handle sensitive personal information or give health interpretation or
advice, higher degrees of risk are involved than for apps that do not collect personal information
or do not interpret or advise. If some information identified during this step should be disclosed
to consumers, that is stated in the “Informing Consumers/Users” section.
Related Regulations and Standards:
While mobile computing environments may introduce some specific threats not present in non-mobilecomputing, the principles of risk management
are the same across environments, so some standards and regulations are cited, even though they are not mobile-centric. Documents (listed
alphabetically below) were sources of some cMHAFF criteria for risk assessment. Other useful references on risk assessment are listed in the
Appendix. While some are realm-specific, they have much material that is applicable beyond their countries. Realms are listed in parentheses, if not
explicit in the title.
Andalusian Complete list of recommendations on design, use and assessment of health apps:
http://www.calidadappsalud.com/en/listado-completo-recomendaciones-app-salud/
• British Standards Institution Publicly Available Specification (PAS) 277:2015 Health and wellness apps – Quality criteria across
the life cycle – Code of practice: Recommendations andguidance throughout the app’s product development life cycle
• French Good Practice Guidelines on Health Apps and Smart Devices (Mobile Health or mHealth). https://www.has-
sante.fr/portail/upload/docs/application/pdf/2017-
03/dir1/good_practice_guidelines_on_health_apps_and_smart_devices_mobile_health_or_mh ealth.pdf
• National Institute of Standards and Technology NISTIR 8144 Assessing Threats to MobileDevices & Infrastructure, The
Mobile Threat Catalogue (USA) https://nccoe.nist.gov/sites/default/files/library/mtc-nistir-8144-draft.pdf (context and background
information)
https://pages.nist.gov/mobile-threat-catalogue/application.html#vulnerable-applications (actual catalog of threats, specifically the “Vulnerable
Application” category, which is the part ofthe threat catalog closest to cMHAFF)
• Open Web Application Security Project (OWASP) Top 10 Mobile Security Risks:
https://www.owasp.org/index.php/Mobile_Top_10_2016-Top_10 This is focused on appdevelopers, so most of it is pertinent to
cMHAFF, and for each risk, there are suggested mitigations.
• OWASP Secure Coding Practices Quick Reference Guide: https://owasp.org/www-project-secure-coding-practices-quick-
reference-guide/ - This provides resources for developers that can assist in implementing secure coding practices. It is
recommended that developers adopt secure coding practices so that applications are developed with an emphasis on security vs
having to apply security measures to protect the application.
Example:
While later sections in this standard include specific security and privacy controls to be applied to consumer mobile health apps, all products addressing
health issues, regardless of their type, must be subjected to an overall risk analysis. This risk analysis may uncover the need for additional security controls
over-and-above the conformance statements included in this document. As such, a risk analysis provides an additional layer of considerations such that
conformance statements are not misused as a simple checklist in which it is assumed all security risks have been addressed if an app is in compliance
with the conformance statements in this standard. For an app/product, the risk analysis should be conducted for the target environment(s) where the app
will actually be used by consumers. Because of the diversity of consumers, such a risk analysis is wider ranging and more challenging than a risk analysis
for the development organization’s own environment."/>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-01"/>
<label value="PDS.2#01"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL conform to a product risk assessment and mitigation plan defined by the developer. The plan explicitly determines which risks are addressed through software coding, hardware adaptation, or policy, and which residual risks are accepted by the entity responsible for the system. The developer maintains, reviews, and updates an organizational risk register that includes risks associated with the mobile application."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-02"/>
<label value="PDS.2#02"/>
<conformance value="SHALL"/>
<conditionality value="true"/>
<requirement
value="IF the system uses AI functionality THEN the system SHALL extend its product risk assessment and mitigation plan to address AI-specific hazards, including incorrect or fabricated output, unsafe recommendations, biased performance, data drift, privacy leakage, adversarial or malicious inputs, prompt injection, automation bias, over-reliance, and inappropriate use outside the intended context."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-03"/>
<label value="PDS.2#03"/>
<conformance value="SHALL"/>
<conditionality value="false"/>
<requirement
value="The system SHALL be developed following secure coding practices using an established risk assessment framework."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-04"/>
<label value="PDS.2#04"/>
<conformance value="SHALL"/>
<conditionality value="true"/>
<requirement
value="IF the system collects personally identifiable information THEN the system SHALL be developed in accordance with risk assessment findings regarding the adequate protection of an individual's personally identifiable information (PII), any protected health information (PHI), and information used to access an EHR or PHR, such as logon credentials."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-05"/>
<label value="PDS.2#05"/>
<conformance value="SHALL"/>
<conditionality value="true"/>
<requirement
value="IF the system transmits data to an EHR THEN the system SHALL document failure rates, measurement error rates, software defects, and hardware risks of all types."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-06"/>
<label value="PDS.2#06"/>
<conformance value="SHALL"/>
<conditionality value="true"/>
<requirement
value="IF AI output can influence a high-impact health, safety, or access decision THEN the system SHALL define and test risk controls, escalation paths, user-facing limitations, and a safe fallback behavior for AI unavailability, low confidence, conflicting inputs, or detected unsafe output."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-07"/>
<label value="PDS.2#07"/>
<conformance value="SHALL"/>
<conditionality value="true"/>
<requirement
value="IF the system includes generative AI or an AI agent THEN the system SHALL perform pre-deployment testing for unsafe content, unsupported medical claims, prompt injection, data exfiltration, harmful instructions, and unintended actions appropriate to the system's intended use and consumer population."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-08"/>
<label value="PDS.2#08"/>
<conformance value="SHOULD"/>
<conditionality value="false"/>
<requirement
value="The system SHOULD be approved through User Acceptance Testing (UAT) conducted by testers who are not part of the formal development team, prior to product launch."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-09"/>
<label value="PDS.2#09"/>
<conformance value="SHOULD"/>
<conditionality value="true"/>
<requirement
value="IF the system uses AI functionality THEN the system SHOULD predefine performance, safety, fairness, and usability acceptance thresholds that are proportionate to the intended use and identify the actions taken when a threshold is not met."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-10"/>
<label value="PDS.2#10"/>
<conformance value="SHOULD"/>
<conditionality value="false"/>
<requirement
value="The system SHOULD be monitored for, and SHOULD document, conflicts or compatibility issues with other applications, device features such as the camera, or connected devices."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-11"/>
<label value="PDS.2#11"/>
<conformance value="SHOULD"/>
<conditionality value="true"/>
<requirement
value="IF the system relies on external supporting infrastructure, such as cloud-based servers, to operate THEN the system SHOULD document measures that ensure the availability of that infrastructure."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-12"/>
<label value="PDS.2#12"/>
<conformance value="MAY"/>
<conditionality value="false"/>
<requirement
value="The system MAY provide documentation showing that the publisher has adequate resources to continue to develop, maintain, and support the product, such as human resources, finances, intellectual property rights, facilities, equipment, and tools."/>
</statement>
<statement>
<extension
url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
<valueBoolean value="false"/>
</extension>
<key value="CMHAFFR2-PDS.2-13"/>
<label value="PDS.2#13"/>
<conformance value="MAY"/>
<conditionality value="true"/>
<requirement
value="IF the system uses AI functionality THEN the system MAY use independent evaluators, red-team testing, or external subject-matter experts to challenge assumptions and identify unanticipated AI risks before or after release."/>
</statement>