Consumer Mobile Health Application Functional Framework, Release 2
2.0.1 - CI build International flag

Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions

: APU.3 Pairing or Syncing User Accounts with Devices and Data Repositories (Function)

Page standards status: Informative

Raw xml | Download


<Requirements xmlns="http://hl7.org/fhir">
  <id value="CMHAFFR2-APU.3"/>
  <meta>
    <profile
             value="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    
    
    
    
    <div id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></div>
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#01
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>The system SHALL ensure that the user has successfully authenticated and has an active session before an external device is paired to an account.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#02
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>The system SHALL display a screen that asks the user to confirm that the device will collect information about a specific, named person, before a device is paired with the system to collect information about that individual. The person may be the account holder or a proxy subject of the account holder.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#03
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>The system SHALL provide a utility function that permits the person who paired a device with an individual to un-pair the device and the individual.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#04
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>The system SHALL state what data will be collected by the device and how that data is used, before a device is paired with the system to collect information about a specific individual. This statement may include a link to an informational page giving details about data collection and use.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#05
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system uses device or repository data as input to AI functionality THEN the system SHALL state, before a device or repository is paired or synced, whether data from that device or repository will be used as input to AI functionality and for what purpose.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#06
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF data for more than one person can be collected by the system and device pair THEN the system SHALL ask the account holder to confirm the person for whom the device will collect data, before data is collected and transmitted.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#07
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system includes a syncing option, such as the same data synchronized across smartphone and tablet devices, THEN the system SHALL provide the user with the option to consent to the syncing process.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            APU.3#08
            </td>
            <td style="padding-left: 4px;">
            SHOULD
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF AI output depends on data from a paired device or repository THEN the system SHOULD detect or flag material missing, stale, implausible, or mis-associated inputs before presenting an AI output that relies on those inputs.</p>

                
            </td>
        </tr>
        
    </table>
    
</div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="mobile"/>
  </extension>
  <url value="http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-APU.3"/>
  <version value="2.0.1"/>
  <name
        value="APU_3_Pairing_or_Syncing_User_Accounts_with_Devices_and_Data_Repositories"/>
  <title
         value="APU.3 Pairing or Syncing User Accounts with Devices and Data Repositories (Function)"/>
  <status value="active"/>
  <date value="2026-11-18T11:24:54+00:00"/>
  <publisher value="HL7 International / Mobile Health"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/mobile"/>
    </telecom>
  </contact>
  <description
               value="This category is about consumer verification of all devices to which they wish to pair or sync data."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-01"/>
    <label value="APU.3#01"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL ensure that the user has successfully authenticated and has an active session before an external device is paired to an account."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-02"/>
    <label value="APU.3#02"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL display a screen that asks the user to confirm that the device will collect information about a specific, named person, before a device is paired with the system to collect information about that individual. The person may be the account holder or a proxy subject of the account holder."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-03"/>
    <label value="APU.3#03"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL provide a utility function that permits the person who paired a device with an individual to un-pair the device and the individual."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-04"/>
    <label value="APU.3#04"/>
    <conformance value="SHALL"/>
    <conditionality value="false"/>
    <requirement
                 value="The system SHALL state what data will be collected by the device and how that data is used, before a device is paired with the system to collect information about a specific individual. This statement may include a link to an informational page giving details about data collection and use."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-05"/>
    <label value="APU.3#05"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system uses device or repository data as input to AI functionality THEN the system SHALL state, before a device or repository is paired or synced, whether data from that device or repository will be used as input to AI functionality and for what purpose."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-06"/>
    <label value="APU.3#06"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF data for more than one person can be collected by the system and device pair THEN the system SHALL ask the account holder to confirm the person for whom the device will collect data, before data is collected and transmitted."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-07"/>
    <label value="APU.3#07"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system includes a syncing option, such as the same data synchronized across smartphone and tablet devices, THEN the system SHALL provide the user with the option to consent to the syncing process."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-APU.3-08"/>
    <label value="APU.3#08"/>
    <conformance value="SHOULD"/>
    <conditionality value="true"/>
    <requirement
                 value="IF AI output depends on data from a paired device or repository THEN the system SHOULD detect or flag material missing, stale, implausible, or mis-associated inputs before presenting an AI output that relies on those inputs."/>
  </statement>
</Requirements>