Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions

: AIG.8 AI Supplier and Third-Party Component Management (Function)

Page standards status: Informative

Raw xml | Download


<Requirements xmlns="http://hl7.org/fhir">
  <id value="CMHAFFR2-AIG.8"/>
  <meta>
    <profile
             value="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    
    
    
    
    <div id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></div>
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.8#01
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system relies on an external AI model, service, dataset, tool, or content source THEN the system SHALL assess and document the supplier's role, applicable data flows, security and privacy controls, model or service versioning, change-notice practices, incident-notification obligations, and ability to support an audit or investigation.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.8#02
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system relies on an external AI component THEN the system SHALL maintain the ability to identify the component version in use and to suspend or replace the component when a material safety, privacy, security, or performance issue is identified.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.8#03
            </td>
            <td style="padding-left: 4px;">
            SHOULD
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system relies on an external AI component THEN the system SHOULD evaluate material supplier changes before enabling them for consumers and SHOULD retain evidence of the review.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.8#04
            </td>
            <td style="padding-left: 4px;">
            MAY
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system relies on an external AI component THEN the system MAY maintain an exit, substitution, or data-portability plan for critical AI suppliers to reduce dependency and continuity risk.</p>

                
            </td>
        </tr>
        
    </table>
    
</div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="mobile"/>
  </extension>
  <url value="http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-AIG.8"/>
  <version value="2.0.1"/>
  <name value="AIG_8_AI_Supplier_and_Third_Party_Component_Management"/>
  <title
         value="AIG.8 AI Supplier and Third-Party Component Management (Function)"/>
  <status value="active"/>
  <date value="2026-11-18T11:24:54+00:00"/>
  <publisher value="HL7 International / Mobile Health"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/mobile"/>
    </telecom>
  </contact>
  <description
               value="This category applies where AI functionality depends on an external model, service, dataset, tool, or content source. Supplier-side changes can alter performance or data handling without any change to the application itself."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.8-01"/>
    <label value="AIG.8#01"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system relies on an external AI model, service, dataset, tool, or content source THEN the system SHALL assess and document the supplier's role, applicable data flows, security and privacy controls, model or service versioning, change-notice practices, incident-notification obligations, and ability to support an audit or investigation."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.8-02"/>
    <label value="AIG.8#02"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system relies on an external AI component THEN the system SHALL maintain the ability to identify the component version in use and to suspend or replace the component when a material safety, privacy, security, or performance issue is identified."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.8-03"/>
    <label value="AIG.8#03"/>
    <conformance value="SHOULD"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system relies on an external AI component THEN the system SHOULD evaluate material supplier changes before enabling them for consumers and SHOULD retain evidence of the review."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.8-04"/>
    <label value="AIG.8#04"/>
    <conformance value="MAY"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system relies on an external AI component THEN the system MAY maintain an exit, substitution, or data-portability plan for critical AI suppliers to reduce dependency and continuity risk."/>
  </statement>