@prefix fhir: <http://hl7.org/fhir/> .
@prefix owl: <http://www.w3.org/2002/07/owl#> .
@prefix rdf: <http://www.w3.org/1999/02/22-rdf-syntax-ns#> .
@prefix rdfs: <http://www.w3.org/2000/01/rdf-schema#> .
@prefix xsd: <http://www.w3.org/2001/XMLSchema#> .

# - resource -------------------------------------------------------------------

<http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-AIG.5> a fhir:Requirements ;
  fhir:nodeRole fhir:treeRoot ;
  fhir:id [ fhir:v "CMHAFFR2-AIG.5"] ; # 
  fhir:meta [
     fhir:profile ( [
       fhir:v "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"^^xsd:anyURI ;
       fhir:link <http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction>
     ] )
  ] ; # 
  fhir:language [ fhir:v "en"] ; # 
  fhir:text [
     fhir:status [ fhir:v "extensions" ] ;
     fhir:div [ fhir:v "<div xmlns=\"http://www.w3.org/1999/xhtml\">\n    \n    \n    \n    \n    <div id=\"requirements\"><b>Criteria <a href=\"https://hl7.org/fhir/versions.html#std-process\" title=\"Normative Content\" class=\"normative-flag\">N</a>:</b></div>\n    <table id=\"statements\" class=\"grid dict\">\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n            AIG.5#01\n            </td>\n            <td style=\"padding-left: 4px;\">\n            SHALL\n            \n            \n            <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n            \n            \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                <p>IF an AI function can influence a high-impact health, safety, access, or financial decision THEN the system SHALL provide a risk-appropriate human or consumer review, correction, override, or escalation pathway before an irreversible or high-impact action is taken, unless a documented exception is required for immediate safety and is permitted by applicable rules.</p>\n\n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n            AIG.5#02\n            </td>\n            <td style=\"padding-left: 4px;\">\n            SHALL\n            \n            \n            <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n            \n            \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                <p>IF the system uses AI functionality THEN the system SHALL enable a consumer to view or correct material input data that the consumer provided or that the system attributes to the consumer when incorrect input could materially affect the AI output.</p>\n\n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n            AIG.5#03\n            </td>\n            <td style=\"padding-left: 4px;\">\n            SHOULD\n            \n            \n            <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n            \n            \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                <p>IF the system displays AI output THEN the system SHOULD provide a meaningful explanation of the primary factors, data limitations, or evidence sources relevant to the output, at a level appropriate to the consumer and the risk of the intended use.</p>\n\n                \n            </td>\n        </tr>\n        \n        <tr>\n            <td style=\"padding-left: 4px;\">\n            AIG.5#04\n            </td>\n            <td style=\"padding-left: 4px;\">\n            MAY\n            \n            \n            <span style=\"border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;\">conditional</span>\n            \n            \n            </td>\n            <td style=\"padding-left: 4px;\" class=\"requirement\">\n                <p>IF the system uses AI functionality THEN the system MAY offer alternative explanation formats, such as plain-language summaries, detailed technical explanations, visual context, or translated content.</p>\n\n                \n            </td>\n        </tr>\n        \n    </table>\n    \n</div>"^^rdf:XMLLiteral ]
  ] ; # 
  fhir:extension ( [
     fhir:url [ fhir:v "http://hl7.org/fhir/StructureDefinition/structuredefinition-wg"^^xsd:anyURI ] ;
     fhir:value [
       a fhir:code ;
       fhir:v "mobile"
     ]
  ] ) ; # 
  fhir:url [ fhir:v "http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-AIG.5"^^xsd:anyURI] ; # 
  fhir:version [ fhir:v "2.0.1"] ; # 
  fhir:name [ fhir:v "AIG_5_Human_Factors__Explainability__and_Human_Oversight"] ; # 
  fhir:title [ fhir:v "AIG.5 Human Factors, Explainability, and Human Oversight (Function)"] ; # 
  fhir:status [ fhir:v "active"] ; # 
  fhir:date [ fhir:v "2026-11-18T11:24:54+00:00"^^xsd:dateTime] ; # 
  fhir:publisher [ fhir:v "HL7 International / Mobile Health"] ; # 
  fhir:contact ( [
     fhir:telecom ( [
       fhir:system [ fhir:v "url" ] ;
       fhir:value [ fhir:v "http://www.hl7.org/Special/committees/mobile" ]
     ] )
  ] ) ; # 
  fhir:description [ fhir:v "This category is about what the consumer can see, correct, question, and override. It covers review and escalation pathways before high-impact or irreversible actions, correction of faulty input data, and explanation at a level appropriate to the consumer and the risk of the intended use."] ; # 
  fhir:jurisdiction ( [
     fhir:coding ( [
       fhir:system [ fhir:v "http://unstats.un.org/unsd/methods/m49/m49.htm"^^xsd:anyURI ] ;
       fhir:code [ fhir:v "001" ] ;
       fhir:display [ fhir:v "World" ]
     ] )
  ] ) ; # 
  fhir:statement ( [
     fhir:extension ( [
       fhir:url [ fhir:v "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
       fhir:value [
         a fhir:boolean ;
         fhir:v false
       ]
     ] ) ;
     fhir:key [ fhir:v "CMHAFFR2-AIG.5-01" ] ;
     fhir:label [ fhir:v "AIG.5#01" ] ;
     fhir:conformance ( [ fhir:v "SHALL" ] ) ;
     fhir:conditionality [ fhir:v true ] ;
     fhir:requirement [ fhir:v "IF an AI function can influence a high-impact health, safety, access, or financial decision THEN the system SHALL provide a risk-appropriate human or consumer review, correction, override, or escalation pathway before an irreversible or high-impact action is taken, unless a documented exception is required for immediate safety and is permitted by applicable rules." ]
  ] [
     fhir:extension ( [
       fhir:url [ fhir:v "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
       fhir:value [
         a fhir:boolean ;
         fhir:v false
       ]
     ] ) ;
     fhir:key [ fhir:v "CMHAFFR2-AIG.5-02" ] ;
     fhir:label [ fhir:v "AIG.5#02" ] ;
     fhir:conformance ( [ fhir:v "SHALL" ] ) ;
     fhir:conditionality [ fhir:v true ] ;
     fhir:requirement [ fhir:v "IF the system uses AI functionality THEN the system SHALL enable a consumer to view or correct material input data that the consumer provided or that the system attributes to the consumer when incorrect input could materially affect the AI output." ]
  ] [
     fhir:extension ( [
       fhir:url [ fhir:v "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
       fhir:value [
         a fhir:boolean ;
         fhir:v false
       ]
     ] ) ;
     fhir:key [ fhir:v "CMHAFFR2-AIG.5-03" ] ;
     fhir:label [ fhir:v "AIG.5#03" ] ;
     fhir:conformance ( [ fhir:v "SHOULD" ] ) ;
     fhir:conditionality [ fhir:v true ] ;
     fhir:requirement [ fhir:v "IF the system displays AI output THEN the system SHOULD provide a meaningful explanation of the primary factors, data limitations, or evidence sources relevant to the output, at a level appropriate to the consumer and the risk of the intended use." ]
  ] [
     fhir:extension ( [
       fhir:url [ fhir:v "http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent"^^xsd:anyURI ] ;
       fhir:value [
         a fhir:boolean ;
         fhir:v false
       ]
     ] ) ;
     fhir:key [ fhir:v "CMHAFFR2-AIG.5-04" ] ;
     fhir:label [ fhir:v "AIG.5#04" ] ;
     fhir:conformance ( [ fhir:v "MAY" ] ) ;
     fhir:conditionality [ fhir:v true ] ;
     fhir:requirement [ fhir:v "IF the system uses AI functionality THEN the system MAY offer alternative explanation formats, such as plain-language summaries, detailed technical explanations, visual context, or translated content." ]
  ] ) . # 

# -------------------------------------------------------------------------------------

