Consumer Mobile Health Application Functional Framework, Release 2
2.0.1 - CI build International flag

Consumer Mobile Health Application Functional Framework, Release 2, published by HL7 International / Mobile Health. This guide is not an authorized publication; it is the continuous build for version 2.0.1 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cmhaff-ig/ and changes regularly. See the Directory of published versions

: AIG.2 AI Governance and Accountability (Function)

Page standards status: Informative

Raw xml | Download


<Requirements xmlns="http://hl7.org/fhir">
  <id value="CMHAFFR2-AIG.2"/>
  <meta>
    <profile
             value="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/FMFunction"/>
  </meta>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml">
    
    
    
    
    <div id="requirements"><b>Criteria <a href="https://hl7.org/fhir/versions.html#std-process" title="Normative Content" class="normative-flag">N</a>:</b></div>
    <table id="statements" class="grid dict">
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.2#01
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system uses AI functionality THEN the system SHALL designate an accountable organization and accountable role for the governance, safety, privacy, performance monitoring, and retirement of each AI function.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.2#02
            </td>
            <td style="padding-left: 4px;">
            SHALL
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system uses AI functionality THEN the system SHALL establish documented approval criteria for AI design, validation, deployment, material change, suspension, and retirement, including the circumstances requiring review by safety, clinical, privacy, security, or legal personnel.</p>

                
            </td>
        </tr>
        
        <tr>
            <td style="padding-left: 4px;">
            AIG.2#03
            </td>
            <td style="padding-left: 4px;">
            MAY
            
            
            <span style="border-radius: 999px;margin: 2px 2px;font-size: 10px;display: inline-block;padding: 3px 5px;letter-spacing: 0.5px;line-height: 1;white-space: nowrap;background-color: #f3e5ff;color: #7b1fa2;border: 1px solid #d1a3ff;">conditional</span>
            
            
            </td>
            <td style="padding-left: 4px;" class="requirement">
                <p>IF the system uses AI functionality THEN the system MAY establish an independent advisory group or external review mechanism for AI functions with elevated safety, equity, or consumer-protection risk.</p>

                
            </td>
        </tr>
        
    </table>
    
</div>
  </text>
  <extension
             url="http://hl7.org/fhir/StructureDefinition/structuredefinition-wg">
    <valueCode value="mobile"/>
  </extension>
  <url value="http://hl7.org/ehrs/uv/cmhaffr2/Requirements/CMHAFFR2-AIG.2"/>
  <version value="2.0.1"/>
  <name value="AIG_2_AI_Governance_and_Accountability"/>
  <title value="AIG.2 AI Governance and Accountability (Function)"/>
  <status value="active"/>
  <date value="2026-11-18T11:24:54+00:00"/>
  <publisher value="HL7 International / Mobile Health"/>
  <contact>
    <telecom>
      <system value="url"/>
      <value value="http://www.hl7.org/Special/committees/mobile"/>
    </telecom>
  </contact>
  <description
               value="This category is about named, documented responsibility for each AI function across its lifecycle, and about the approval gates that make that responsibility operational rather than aspirational."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.2-01"/>
    <label value="AIG.2#01"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system uses AI functionality THEN the system SHALL designate an accountable organization and accountable role for the governance, safety, privacy, performance monitoring, and retirement of each AI function."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.2-02"/>
    <label value="AIG.2#02"/>
    <conformance value="SHALL"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system uses AI functionality THEN the system SHALL establish documented approval criteria for AI design, validation, deployment, material change, suspension, and retirement, including the circumstances requiring review by safety, clinical, privacy, security, or legal personnel."/>
  </statement>
  <statement>
    <extension
               url="http://hl7.org/ehrs/uv/cmhaffr2/StructureDefinition/requirements-dependent">
      <valueBoolean value="false"/>
    </extension>
    <key value="CMHAFFR2-AIG.2-03"/>
    <label value="AIG.2#03"/>
    <conformance value="MAY"/>
    <conditionality value="true"/>
    <requirement
                 value="IF the system uses AI functionality THEN the system MAY establish an independent advisory group or external review mechanism for AI functions with elevated safety, equity, or consumer-protection risk."/>
  </statement>
</Requirements>