Profile Comparison between http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment vs http://hl7.org/fhir/us/vitals/StructureDefinition/twenty-four-hour-blood-pressure

Left:US Core Observation Screening Assessment Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment)
Right:Twenty Four Hour Blood Pressure (http://hl7.org/fhir/us/vitals/StructureDefinition/twenty-four-hour-blood-pressure)

Messages

ErrorStructureDefinition.urlValues for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment' vs 'http://hl7.org/fhir/us/vitals/StructureDefinition/twenty-four-hour-blood-pressure'
ErrorStructureDefinition.versionValues for version differ: '7.0.0' vs '2.0.0'
InformationStructureDefinition.nameValues for name differ: 'USCoreObservationScreeningAssessmentProfile' vs 'TwentyFourHourBloodPressure'
InformationStructureDefinition.titleValues for title differ: 'US Core Observation Screening Assessment Profile' vs 'Twenty Four Hour Blood Pressure'
InformationStructureDefinition.statusValues for status differ: 'active' vs 'draft'
InformationStructureDefinition.dateValues for date differ: '2023-10-17' vs '2024-10-09T23:56:46+00:00'
InformationStructureDefinition.publisherValues for publisher differ: 'HL7 International / Cross-Group Projects' vs 'HL7 International - Clinical Information Modeling Initiative'
InformationStructureDefinition.copyrightValues for copyright differ: 'Used by permission of HL7 International, all rights reserved Creative Commons License' vs 'Logica Health, all rights reserved Creative Commons License'
InformationStructureDefinition.jurisdictionRemoved the item 'urn:iso:std:iso:3166#US'
InformationStructureDefinition.jurisdictionAdded the item 'http://unstats.un.org/unsd/methods/m49/m49.htm#001'
ErrorStructureDefinition.baseDefinitionValues for baseDefinition differ: 'http://hl7.org/fhir/StructureDefinition/Observation' vs 'http://hl7.org/fhir/StructureDefinition/vitalsigns'
InformationStructureDefinition.shortValues for short differ: 'Survey Observation' vs 'FHIR Vital Signs Profile'
InformationStructureDefinition.definitionValues for definition differ: 'Measurements and simple assertions made about a patient, device or other subject.' vs 'The FHIR Vitals Signs profile sets minimum expectations for the Observation Resource to record, search and fetch the vital signs associated with a patient.'
InformationStructureDefinition.shortValues for short differ: 'Additional content defined by implementations' vs 'Extension'
InformationStructureDefinition.definitionValues for definition differ: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension'
InformationStructureDefinition.requirementsValues for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).'
InformationStructureDefinition.commentValues for comment differ: 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below for guidance on referencing another Observation.' vs 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below for guidance on referencing another Observation.'
InformationStructureDefinition.shortValues for short differ: 'Type of observation (code / type)' vs 'Blood pressure panel 24 hour mean'
InformationStructureDefinition.definitionValues for definition differ: 'Describes what was observed. Sometimes this is called the observation 'name'.' vs 'Coded Responses from C-CDA Vital Sign Results.'
InformationStructureDefinition.requirementsValues for requirements differ: 'Knowing what kind of observation is being made is essential to understanding the observation.' vs '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).'
InformationStructureDefinition.commentValues for comment differ: 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/R4/extension-observation-focuscode.html).' vs 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/extension-observation-focuscode.html).'
InformationStructureDefinition.shortValues for short differ: 'Clinically relevant time/time-period for observation' vs 'The dates and times over which the 24 hour period falls.'
InformationStructureDefinition.definitionValues for definition differ: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g., human patients - this is usually called the 'physiologically relevant time'.' vs 'Often just a dateTime for Vital Signs.'
InformationStructureDefinition.commentValues for comment differ: 'At least a date should be present unless this observation is a historical report.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.'
InformationObservation.effective[x]Element minimum cardinalities differ: '0' vs '1'
InformationStructureDefinition.commentValues for comment differ: 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/R4/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' vs 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.'
WarningObservation.performerElements differ in definition for mustSupport: 'true' vs 'false'
InformationStructureDefinition.shortValues for short differ: 'Actual result' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
InformationStructureDefinition.definitionValues for definition differ: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.'
InformationStructureDefinition.commentValues for comment differ: 'An observation may have a value if it represents an individual survey, screening, or assessment question and answer pair. An observation should not have a value if it represents a multi-question or multi-select “check all that apply” responses. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value.' vs 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.'
InformationStructureDefinition.requirementsValues for requirements differ: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
InformationObservation.value[x]Element maximum cardinalities differ: '1' vs '0'
InformationStructureDefinition.commentValues for comment differ: ''Null' or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For a given LOINC question, if the LOINC answer list includes concepts such as 'unknown' or 'not available', they should be used for Observation.value. Where these concepts are not part of the value set for Observation.value, the Observation.dataAbsentReason can be used if necessary and appropriate.' vs 'Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be 'detected', 'not detected', 'inconclusive', or 'specimen unsatisfactory'. The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code 'error' could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.'
InformationStructureDefinition.commentValues for comment differ: 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/R4/extension-bodysite.html).' vs 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/extension-bodysite.html).'
WarningObservation.bodySiteElements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.methodElements differ in definition for mustSupport: 'false' vs 'true'
InformationObservation.specimenElement maximum cardinalities differ: '1' vs '0'
InformationStructureDefinition.shortValues for short differ: '(Measurement) Device' vs 'Blood Pressure Device'
WarningObservation.deviceElements differ in definition for mustSupport: 'false' vs 'true'
InformationStructureDefinition.requirementsValues for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).'
InformationStructureDefinition.shortValues for short differ: 'Reference to panel members or multi-select responses or multi-select responses' vs 'Used when reporting vital signs panel components'
InformationStructureDefinition.definitionValues for definition differ: 'Aggregate set of Observations that represent question answer pairs for both multi-question surveys, screenings, and assessments and multi-select questions.' vs 'Used when reporting vital signs panel components.'
InformationStructureDefinition.commentValues for comment differ: 'This grouping element is used to represent surveys, screenings, and assessments that group several questions together or individual questions with “check all that apply” responses. For example in the simplest case a flat multi-question survey where the 'panel' observation is the survey instrument itself and instead of an `Observation.value` the `hasMember` element references other Observation that represent the individual questions answer pairs. When there is a heirarchical grouping of questions, the observation 'panels' can be nested. Because surveys, screenings, and assessments can be arbitrarily complex structurally, not all structures can be represented using this Observation grouping pattern.' vs 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/questionnaireresponse.html) into a final score and represent the score as an Observation.'
WarningObservation.hasMemberElements differ in definition for mustSupport: 'true' vs 'false'
ErrorObservation.hasMemberType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
InformationStructureDefinition.shortValues for short differ: '𝗔𝗗𝗗𝗜𝗧𝗜𝗢𝗡𝗔𝗟 𝗨𝗦𝗖𝗗𝗜: Related Observation(s) or other resource the observation is made from' vs 'Related measurements the observation is made from'
InformationStructureDefinition.definitionValues for definition differ: 'Observations or or other resource such as a QuestionnaireResponse from which this observation value is derived.' vs 'The target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image.'
InformationStructureDefinition.commentValues for comment differ: 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below.' vs 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below.'
WarningObservation.derivedFromElements differ in definition for mustSupport: 'true' vs 'false'
ErrorObservation.derivedFromType Mismatch: Reference([CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-questionnaireresponse], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-documentreference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
InformationStructureDefinition.shortValues for short differ: 'Component results' vs 'Blood pressure components'
InformationStructureDefinition.definitionValues for definition differ: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' vs 'Used when reporting systolic and diastolic blood pressure.'
InformationStructureDefinition.commentValues for comment differ: 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/R4/observation.html#notes) below.' vs 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/observation.html#notes) below.'
WarningObservation.componentElements differ in definition for mustSupport: 'false' vs 'true'
InformationObservation.componentElement minimum cardinalities differ: '0' vs '1'
InformationStructureDefinition.requirementsValues for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).'
WarningObservation.component.codeElements differ in definition for mustSupport: 'false' vs 'true'
InformationStructureDefinition.shortValues for short differ: 'Actual component result' vs 'Vital Sign Value recorded with UCUM'
InformationStructureDefinition.definitionValues for definition differ: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Sign Value recorded with UCUM.'
InformationStructureDefinition.commentValues for comment differ: 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' vs 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.'
InformationStructureDefinition.requirementsValues for requirements differ: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).'
WarningObservation.component.value[x]Elements differ in definition for mustSupport: 'false' vs 'true'
WarningObservation.component.dataAbsentReasonElements differ in definition for mustSupport: 'false' vs 'true'

Metadata

NameValueComments
.abstractfalse
    .baseDefinitionhttp://hl7.org/fhir/StructureDefinition/Observationhttp://hl7.org/fhir/StructureDefinition/vitalsigns
    • Values Differ
    .copyrightUsed by permission of HL7 International, all rights reserved Creative Commons LicenseLogica Health, all rights reserved Creative Commons License
    • Values Differ
    .date2023-10-172024-10-09T23:56:46+00:00
    • Values Differ
    .descriptionThe US Core Observation Screening Assessment Profile inherits from the FHIR [Observation](https://hl7.org/fhir/R4/observation.html) resource; refer to it for scope and usage definitions. This profile meets the requirements of the U.S. Core Data for Interoperability (USCDI) *Health Status Assessments* Data Class. It sets the minimum expectations for the Observation Resource to record, search, and fetch observations representing the questions and responses to surveys and screening and assessment tools. For example, a social history status such as education or food insecurity or an assessment of cognitive, functional, or disability status. It can represent a single response, multiple responses, and multi-select "check all that apply" type questions. This profile specifies which core elements, extensions, vocabularies, and value sets **SHALL** be present in the resource and constrains how the elements are used. Providing the floor for standards development for specific use cases promotes interoperability and adoption. Before reviewing this profile, implementers are encouraged to read the Screening and Assessments guidance page, which documents the process of recording responses and capturing assertions/determinations resulting from surveys and questionnaires.An average blood pressure (systolic and diastolic) over a twenty four hour period.
    • Values Differ
    .experimental
      .fhirVersion4.0.1
        .jurisdiction
          ..jurisdiction[0]urn:iso:std:iso:3166#US
          • Removed the item 'urn:iso:std:iso:3166#US'
          ..jurisdiction[1]http://unstats.un.org/unsd/methods/m49/m49.htm#001
          • Added the item 'http://unstats.un.org/unsd/methods/m49/m49.htm#001'
          .kindresource
            .nameUSCoreObservationScreeningAssessmentProfileTwentyFourHourBloodPressure
            • Values Differ
            .publisherHL7 International / Cross-Group ProjectsHL7 International - Clinical Information Modeling Initiative
            • Values Differ
            .purpose
              .statusactivedraft
              • Values Differ
              .titleUS Core Observation Screening Assessment ProfileTwenty Four Hour Blood Pressure
              • Values Differ
              .typeObservation
                .urlhttp://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessmenthttp://hl7.org/fhir/us/vitals/StructureDefinition/twenty-four-hour-blood-pressure
                • Values Differ
                .version7.0.02.0.0
                • Values Differ

                Structure

                NameL FlagsL Card.L TypeL Description & ConstraintsR FlagsR Card.R TypeR Description & ConstraintsCommentsdoco
                .. Observation C0..*ObservationSurvey Observation
                obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
                obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
                us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present
                C0..*observation-vitalsignsFHIR Vital Signs Profile
                obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present
                obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present
                vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present.
                  ... id Σ0..1idLogical id of this artifactΣ0..1idLogical id of this artifact
                    ... meta Σ0..1MetaMetadata about the resourceΣ0..1MetaMetadata about the resource
                      ... implicitRules ?!Σ0..1uriA set of rules under which this content was created?!Σ0..1uriA set of rules under which this content was created
                        ... language 0..1codeLanguage of the resource content
                        Binding: ?? (preferred): A human language.

                        Additional BindingsPurpose
                        ??Max Binding
                        0..1codeLanguage of the resource content
                        Binding: ?? (preferred): A human language.

                        Additional BindingsPurpose
                        ??Max Binding
                          ... text 0..1NarrativeText summary of the resource, for human interpretation0..1NarrativeText summary of the resource, for human interpretation
                            ... contained 0..*ResourceContained, inline Resources
                            0..*ResourceContained, inline Resources
                              ... extension 0..*ExtensionAdditional content defined by implementations
                              0..*ExtensionExtension
                              Slice: Unordered, Open by value:url
                                ... modifierExtension ?!0..*ExtensionExtensions that cannot be ignored
                                ?!0..*ExtensionExtensions that cannot be ignored
                                  ... identifier Σ0..*IdentifierBusiness Identifier for observation
                                  Σ0..*IdentifierBusiness Identifier for observation
                                    ... basedOn Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                    Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)Fulfills plan, proposal or order
                                      ... partOf Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                      Σ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)Part of referenced event
                                        ... status ?!SΣ1..1coderegistered | preliminary | final | amended +
                                        Binding: ?? (required): Codes providing the status of an observation.

                                        ?!SΣ1..1coderegistered | preliminary | final | amended +
                                        Binding: ?? (required)
                                          ... Slices for category S1..*CodeableConceptClassification of type of observation
                                          Slice: Unordered, Open by pattern:$this
                                          Binding: ?? (preferred): Codes for high level observation categories.


                                          S1..*CodeableConceptClassification of type of observation
                                          Slice: Unordered, Open by value:coding.code, value:coding.system
                                          Binding: ?? (preferred): Codes for high level observation categories.


                                            ... code SΣ1..1CodeableConceptType of observation (code / type)
                                            Binding: ?? (preferred)
                                            SΣ1..1CodeableConceptBlood pressure panel 24 hour mean
                                            Binding: ?? (extensible): This identifies the vital sign result type.


                                            Required Pattern: {"coding":[{"system":"http://loinc.org","code":"97844-5"}]}
                                              ... subject SΣ1..1Reference(US Core Patient Profile S | Group | Device | US Core Location Profile)Who and/or what the observation is aboutSΣ1..1Reference(Patient)Who and/or what the observation is about
                                                ... focus Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                                Σ0..*Reference(Resource)What the observation is about, when it is not about the subject of record
                                                  ... encounter Σ0..1Reference(Encounter)Healthcare event during which this observation is madeΣ0..1Reference(Encounter)Healthcare event during which this observation is made
                                                    ... effective[x] SΣC0..1dateTime S, Period, Timing, instantClinically relevant time/time-period for observation
                                                    us-core-1: Datetime must be at least to day.
                                                    SΣC1..1PeriodThe dates and times over which the 24 hour period falls.
                                                    vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day
                                                    • Element minimum cardinalities differ: '0' vs '1'
                                                    ... issued Σ0..1instantDate/Time this version was made availableΣ0..1instantDate/Time this version was made available
                                                      ... performer SΣ0..*Reference(US Core Practitioner Profile | US Core Organization Profile | US Core Patient Profile | PractitionerRole | US Core CareTeam Profile | US Core RelatedPerson Profile)Who is responsible for the observation
                                                      Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)Who is responsible for the observation
                                                      • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                      ... value[x] SΣC0..1Quantity S, CodeableConcept S, string S, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual result
                                                      us-core-3: SHALL use UCUM for coded quantity units.
                                                      SΣC0..0
                                                      • Element maximum cardinalities differ: '1' vs '0'
                                                      ... dataAbsentReason SC0..1CodeableConceptWhy the result is missing
                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                      SC0..1CodeableConceptWhy the result is missing
                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                        ... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                        Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                        0..*CodeableConceptHigh, low, normal, etc.
                                                        Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                          ... note 0..*AnnotationComments about the observation
                                                          0..*AnnotationComments about the observation
                                                            ... bodySite 0..1CodeableConceptObserved body part
                                                            Binding: ?? (example): Codes describing anatomical locations. May include laterality.

                                                            S0..1CodeableConceptObserved body part
                                                            Binding: ?? (extensible): A set of codes that describe where on/in the body an observation or procedure took place

                                                            • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                            ... method 0..1CodeableConceptHow it was done
                                                            Binding: ?? (example): Methods for simple observations.

                                                            S0..1CodeableConceptHow it was done
                                                            Binding: ?? (extensible): A set of codes that describe the method used to measure a blood pressure

                                                            • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                            ... specimen 0..1Reference(Specimen)Specimen used for this observation0..0
                                                            • Element maximum cardinalities differ: '1' vs '0'
                                                            ... device 0..1Reference(Device | DeviceMetric)(Measurement) DeviceS0..1Reference(Blood Pressure Device)Blood Pressure Device
                                                            • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                            ... referenceRange C0..*BackboneElementProvides guide for interpretation
                                                            obs-3: Must have at least a low or a high or text
                                                            C0..*BackboneElementProvides guide for interpretation
                                                            obs-3: Must have at least a low or a high or text
                                                              .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                .... extension 0..*ExtensionAdditional content defined by implementations
                                                                0..*ExtensionAdditional content defined by implementations
                                                                  .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                  ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                    .... low C0..1??Low Range, if relevantC0..1??Low Range, if relevant
                                                                      .... high C0..1??High Range, if relevantC0..1??High Range, if relevant
                                                                        .... type 0..1CodeableConceptReference range qualifier
                                                                        Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                        0..1CodeableConceptReference range qualifier
                                                                        Binding: ?? (preferred): Code for the meaning of a reference range.

                                                                          .... appliesTo 0..*CodeableConceptReference range population
                                                                          Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                          0..*CodeableConceptReference range population
                                                                          Binding: ?? (example): Codes identifying the population the reference range applies to.


                                                                            .... age 0..1RangeApplicable age range, if relevant0..1RangeApplicable age range, if relevant
                                                                              .... text 0..1stringText based reference range in an observation0..1stringText based reference range in an observation
                                                                                ... hasMember SΣ0..*Reference(US Core Observation Screening Assessment Profile S | QuestionnaireResponse | MolecularSequence)Reference to panel members or multi-select responses or multi-select responses
                                                                                Σ0..*Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Used when reporting vital signs panel components
                                                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
                                                                                ... derivedFrom SΣ0..*Reference(US Core Observation Screening Assessment Profile S | US Core QuestionnaireResponse Profile S | US Core DocumentReference Profile | ImagingStudy | Media | MolecularSequence)𝗔𝗗𝗗𝗜𝗧𝗜𝗢𝗡𝗔𝗟 𝗨𝗦𝗖𝗗𝗜: Related Observation(s) or other resource the observation is made from
                                                                                Σ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile)Related measurements the observation is made from
                                                                                • Elements differ in definition for mustSupport: 'true' vs 'false'
                                                                                • Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-screening-assessment], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-questionnaireresponse], CanonicalType[http://hl7.org/fhir/us/core/StructureDefinition/us-core-documentreference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/DocumentReference], CanonicalType[http://hl7.org/fhir/StructureDefinition/ImagingStudy], CanonicalType[http://hl7.org/fhir/StructureDefinition/Media], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]])
                                                                                ... component Σ0..*BackboneElementComponent results
                                                                                SΣC1..*BackboneElementBlood pressure components
                                                                                Slice: Unordered, Open by pattern:code
                                                                                vs-3: If there is no a value a data absent reason must be present
                                                                                • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                • Element minimum cardinalities differ: '0' vs '1'
                                                                                .... id 0..1stringUnique id for inter-element referencing0..1stringUnique id for inter-element referencing
                                                                                  .... extension 0..*ExtensionAdditional content defined by implementations
                                                                                  0..*ExtensionAdditional content defined by implementations
                                                                                    .... modifierExtension ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                    ?!Σ0..*ExtensionExtensions that cannot be ignored even if unrecognized
                                                                                      .... code Σ1..1CodeableConceptType of component observation (code / type)
                                                                                      Binding: ?? (example): Codes identifying names of simple observations.

                                                                                      SΣ1..1CodeableConceptType of component observation (code / type)
                                                                                      Binding: ?? (extensible): This identifies the vital sign result type.

                                                                                      • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                      .... value[x] Σ0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodActual component resultSΣC0..1Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, PeriodVital Sign Value recorded with UCUM
                                                                                      Binding: ?? (extensible): Common UCUM units for recording Vital Signs.

                                                                                      • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                      .... dataAbsentReason C0..1CodeableConceptWhy the component result is missing
                                                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                      SC0..1CodeableConceptWhy the component result is missing
                                                                                      Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing.

                                                                                      • Elements differ in definition for mustSupport: 'false' vs 'true'
                                                                                      .... interpretation 0..*CodeableConceptHigh, low, normal, etc.
                                                                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                      0..*CodeableConceptHigh, low, normal, etc.
                                                                                      Binding: ?? (extensible): Codes identifying interpretations of observations.


                                                                                        .... referenceRange 0..*See referenceRange (Observation)Provides guide for interpretation of component result
                                                                                        0..*See referenceRange (Observation)Provides guide for interpretation of component result

                                                                                          doco Documentation for this format