Left: | US Core Laboratory Result Observation Profile (http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab) |
Right: | Body Temperature (http://hl7.org/fhir/us/vitals/StructureDefinition/body-temperature) |
Error | StructureDefinition.url | Values for url differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab' vs 'http://hl7.org/fhir/us/vitals/StructureDefinition/body-temperature' |
Error | StructureDefinition.version | Values for version differ: '7.0.0' vs '2.0.0' |
Information | StructureDefinition.name | Values for name differ: 'USCoreLaboratoryResultObservationProfile' vs 'BodyTemperature' |
Information | StructureDefinition.title | Values for title differ: 'US Core Laboratory Result Observation Profile' vs 'Body Temperature' |
Information | StructureDefinition.status | Values for status differ: 'active' vs 'draft' |
Information | StructureDefinition.date | Values for date differ: '2023-10-17' vs '2024-10-09T23:56:46+00:00' |
Information | StructureDefinition.publisher | Values for publisher differ: 'HL7 International / Cross-Group Projects' vs 'HL7 International - Clinical Information Modeling Initiative' |
Information | StructureDefinition.copyright | Values for copyright differ: 'Used by permission of HL7 International, all rights reserved Creative Commons License' vs 'Logica Health, all rights reserved Creative Commons License' |
Information | StructureDefinition.jurisdiction | Removed the item 'urn:iso:std:iso:3166#US' |
Information | StructureDefinition.jurisdiction | Added the item 'http://unstats.un.org/unsd/methods/m49/m49.htm#001' |
Error | StructureDefinition.baseDefinition | Values for baseDefinition differ: 'http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result' vs 'http://hl7.org/fhir/StructureDefinition/bodytemp' |
Information | StructureDefinition.short | Values for short differ: 'Measurements and simple assertions' vs 'FHIR Body Temperature Profile' |
Information | StructureDefinition.definition | Values for definition differ: 'Measurements and simple assertions made about a patient, device or other subject.' vs 'This profile defines how to represent Body Temperature observations in FHIR using a standard LOINC code and UCUM units of measure.' |
Warning | Observation.meta | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: 'Additional content defined by implementations' vs 'Extension' |
Information | StructureDefinition.definition | Values for definition differ: 'May be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.' vs 'An Extension' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' |
Information | StructureDefinition.comment | Values for comment differ: 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below for guidance on referencing another Observation.' vs 'To link an Observation to an Encounter use `encounter`. See the [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below for guidance on referencing another Observation.' |
Information | StructureDefinition.short | Values for short differ: 'Laboratory Test Name' vs 'Body temperature' |
Information | StructureDefinition.definition | Values for definition differ: 'The name of the clinical test or procedure performed on a patient. A LOINC **SHALL** be used if the concept is present in LOINC.' vs 'Body Temperature.' |
Information | StructureDefinition.comment | Values for comment differ: 'The typical patterns for codes are: 1) a LOINC code either as a translation from a 'local' code or as a primary code, or 2) a local code only if no suitable LOINC exists, or 3) both the local and the LOINC translation. Systems SHALL be capable of sending the local code if one exists. When using LOINC , Use either the SHORTNAME or LONG_COMMON_NAME field for the display.' vs 'additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Knowing what kind of observation is being made is essential to understanding the observation.' vs '5. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).' |
Information | StructureDefinition.comment | Values for comment differ: 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/R4/extension-observation-focuscode.html).' vs 'Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., 'Blood Glucose') and does not need to be represented separately using this element. Use `specimen` if a reference to a specimen is required. If a code is required instead of a resource use either `bodysite` for bodysites or the standard extension [focusCode](http://hl7.org/fhir/extension-observation-focuscode.html).' |
Information | StructureDefinition.short | Values for short differ: 'Encounter associated with Observation' vs 'Healthcare event during which this observation is made' |
Warning | Observation.encounter | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: 'Clinically relevant time/time-period for observation' vs 'Often just a dateTime for Vital Signs' |
Information | StructureDefinition.definition | Values for definition differ: 'The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the 'physiologically relevant time'. This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.' vs 'Often just a dateTime for Vital Signs.' |
Information | StructureDefinition.comment | Values for comment differ: 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/R4/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' vs 'At least a date should be present unless this observation is a historical report. For recording imprecise or 'fuzzy' times (For example, a blood glucose measurement taken 'after breakfast') use the [Timing](http://hl7.org/fhir/datatypes.html#timing) datatype which allow the measurement to be tied to regular life events.' |
Information | Observation.effective[x] | Element minimum cardinalities differ: '0' vs '1' |
Information | StructureDefinition.comment | Values for comment differ: 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/R4/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' vs 'For Observations that don’t require review and verification, it may be the same as the [`lastUpdated` ](http://hl7.org/fhir/resource-definitions.html#Meta.lastUpdated) time of the resource itself. For Observations that do require review and verification for certain updates, it might not be the same as the `lastUpdated` time of the resource itself due to a non-clinically significant update that doesn’t require the new version to be reviewed and verified again.' |
Information | StructureDefinition.short | Values for short differ: 'Result Value' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' |
Information | StructureDefinition.definition | Values for definition differ: 'The Laboratory result value. If a coded value, the valueCodeableConcept.code **SHOULD** be selected from [SNOMED CT](http://hl7.org/fhir/ValueSet/uslab-obs-codedresults) if the concept exists. If a numeric value, valueQuantity.code **SHALL** be selected from [UCUM](http://unitsofmeasure.org). A FHIR [UCUM Codes value set](http://hl7.org/fhir/STU3/valueset-ucum-units.html) that defines all UCUM codes is in the FHIR specification.' vs 'Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.' |
Information | StructureDefinition.comment | Values for comment differ: 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' vs 'An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' |
Information | StructureDefinition.short | Values for short differ: 'Result interpretation' vs 'High, low, normal, etc.' |
Information | StructureDefinition.comment | Values for comment differ: 'Categorical assessment of a laboratory value, often in relation to a test's reference range. Examples include but are not limited to high, low, critical, and normal.' vs 'Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result.' |
Warning | Observation.interpretation | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.comment | Values for comment differ: 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/R4/extension-bodysite.html).' vs 'Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension[ bodySite](http://hl7.org/fhir/extension-bodysite.html).' |
Warning | Observation.bodySite | Elements differ in definition for mustSupport: 'false' vs 'true' |
Warning | Observation.specimen | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.short | Values for short differ: 'Result reference range' vs 'Provides guide for interpretation' |
Information | StructureDefinition.comment | Values for comment differ: 'Upper and lower limit of test values expected for a designated population of individuals. Reference range values may differ by patient characteristics, laboratory test manufacturer and laboratory test performer.' vs 'Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.' |
Warning | Observation.referenceRange | Elements differ in definition for mustSupport: 'true' vs 'false' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' |
Information | StructureDefinition.short | Values for short differ: 'Related resource that belongs to the Observation group' vs 'Used when reporting vital signs panel components' |
Information | StructureDefinition.definition | Values for definition differ: 'This observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group.' vs 'Used when reporting vital signs panel components.' |
Information | StructureDefinition.comment | Values for comment differ: 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](questionnaireresponse.html) into a final score and represent the score as an Observation.' vs 'When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below. Note that a system may calculate results from [QuestionnaireResponse](http://hl7.org/fhir/questionnaireresponse.html) into a final score and represent the score as an Observation.' |
Error | Observation.hasMember | Type Mismatch: Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/Observation], CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence]]) vs Reference([CanonicalType[http://hl7.org/fhir/StructureDefinition/QuestionnaireResponse], CanonicalType[http://hl7.org/fhir/StructureDefinition/MolecularSequence], CanonicalType[http://hl7.org/fhir/StructureDefinition/vitalsigns]]) |
Information | StructureDefinition.comment | Values for comment differ: 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/R4/observation.html#obsgrouping) below.' vs 'All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see [Notes](http://hl7.org/fhir/observation.html#obsgrouping) below.' |
Information | StructureDefinition.short | Values for short differ: 'Component results' vs 'Used when reporting systolic and diastolic blood pressure.' |
Information | StructureDefinition.definition | Values for definition differ: 'Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.' vs 'Used when reporting systolic and diastolic blood pressure.' |
Information | StructureDefinition.comment | Values for comment differ: 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/R4/observation.html#notes) below.' vs 'For a discussion on the ways Observations can be assembled in groups together see [Notes](http://hl7.org/fhir/observation.html#notes) below.' |
Warning | Observation.component | Elements differ in definition for mustSupport: 'false' vs 'true' |
Information | StructureDefinition.requirements | Values for requirements differ: 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/R4/extensibility.html#modifierExtension).' vs 'Modifier extensions allow for extensions that *cannot* be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the [definition of modifier extensions](http://hl7.org/fhir/extensibility.html#modifierExtension).' |
Warning | Observation.component.code | Elements differ in definition for mustSupport: 'false' vs 'true' |
Information | StructureDefinition.short | Values for short differ: 'Actual component result' vs 'Vital Sign Value recorded with UCUM' |
Information | StructureDefinition.definition | Values for definition differ: 'The information determined as a result of making the observation, if the information has a simple value.' vs 'Vital Sign Value recorded with UCUM.' |
Information | StructureDefinition.comment | Values for comment differ: 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/R4/observation.html#notes) below.' vs 'Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the [Notes section](http://hl7.org/fhir/observation.html#notes) below.' |
Information | StructureDefinition.requirements | Values for requirements differ: 'An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.' vs '9. SHALL contain exactly one [1..1] value with @xsi:type='PQ' (CONF:7305).' |
Warning | Observation.component.value[x] | Elements differ in definition for mustSupport: 'false' vs 'true' |
Warning | Observation.component.dataAbsentReason | Elements differ in definition for mustSupport: 'false' vs 'true' |
Name | Value | Comments | |
---|---|---|---|
abstract | false | ||
baseDefinition | http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-clinical-result | http://hl7.org/fhir/StructureDefinition/bodytemp |
|
copyright | Used by permission of HL7 International, all rights reserved Creative Commons License | Logica Health, all rights reserved Creative Commons License |
|
date | 2023-10-17 | 2024-10-09T23:56:46+00:00 |
|
description | The US Core Laboratory Result Observation Profile is based upon the US Core Observation Clinical Result Profile and, along with the US Core DiagnosticReport Profile for Laboratory Results Reporting, meets the U.S. Core Data for Interoperability (USCDI) Laboratory requirements. Laboratory results are grouped and summarized using the DiagnosticReport resource, which references Observation resources. Each Observation resource represents an individual laboratory test and result value, a “nested” panel (such as a microbial susceptibility panel) that references other observations, or rarely a laboratory test with component result values. The US Core Laboratory Result Observation Profile sets minimum expectations for the Observation resource to record, search, and fetch laboratory test results associated with a patient to promote interoperability and adoption through common implementation. It identifies which core elements, extensions, vocabularies, and value sets SHALL be present in the resource and constrains the way the elements are used when using this profile. It provides the floor for standards development for specific use cases. | The measured heat of an individual's body. |
|
experimental | false |
| |
fhirVersion | 4.0.1 | ||
jurisdiction | |||
jurisdiction[0] | urn:iso:std:iso:3166#US |
| |
jurisdiction[1] | http://unstats.un.org/unsd/methods/m49/m49.htm#001 |
| |
kind | resource | ||
name | USCoreLaboratoryResultObservationProfile | BodyTemperature |
|
publisher | HL7 International / Cross-Group Projects | HL7 International - Clinical Information Modeling Initiative |
|
purpose | |||
status | active | draft |
|
title | US Core Laboratory Result Observation Profile | Body Temperature |
|
type | Observation | ||
url | http://hl7.org/fhir/us/core/StructureDefinition/us-core-observation-lab | http://hl7.org/fhir/us/vitals/StructureDefinition/body-temperature |
|
version | 7.0.0 | 2.0.0 |
|
Name | L Flags | L Card. | L Type | L Description & Constraints | R Flags | R Card. | R Type | R Description & Constraints | Comments | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Observation | C | 0..* | USCoreObservationClinicalResultProfile | Measurements and simple assertions obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present us-core-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present | C | 0..* | observation-bodytemp | FHIR Body Temperature Profile obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. | |||||||||
id | Σ | 0..1 | id | Logical id of this artifact | Σ | 0..1 | id | Logical id of this artifact | |||||||||
meta | SΣ | 0..1 | Meta | Metadata about the resource | Σ | 0..1 | Meta | Metadata about the resource |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing |
| |||||||||||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url |
| |||||||||||||
versionId | Σ | 0..1 | id | Version specific identifier |
| ||||||||||||
lastUpdated | SΣ | 0..1 | instant | When the resource last changed |
| ||||||||||||
source | Σ | 0..1 | uri | Identifies where the resource comes from |
| ||||||||||||
profile | Σ | 0..* | canonical(StructureDefinition) | Profiles this resource claims to conform to |
| ||||||||||||
security | Σ | 0..* | Coding | Security Labels applied to this resource Binding: ?? (extensible): Security Labels from the Healthcare Privacy and Security Classification System. |
| ||||||||||||
tag | Σ | 0..* | Coding | Tags applied to this resource Binding: ?? (example): Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". |
| ||||||||||||
implicitRules | ?!Σ | 0..1 | uri | A set of rules under which this content was created | ?!Σ | 0..1 | uri | A set of rules under which this content was created | |||||||||
language | 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
| 0..1 | code | Language of the resource content Binding: ?? (preferred): A human language.
| |||||||||||
text | 0..1 | Narrative | Text summary of the resource, for human interpretation | 0..1 | Narrative | Text summary of the resource, for human interpretation | |||||||||||
contained | 0..* | Resource | Contained, inline Resources | 0..* | Resource | Contained, inline Resources | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Extension Slice: Unordered, Open by value:url | |||||||||||
modifierExtension | ?! | 0..* | Extension | Extensions that cannot be ignored | ?! | 0..* | Extension | Extensions that cannot be ignored | |||||||||
identifier | Σ | 0..* | Identifier | Business Identifier for observation | Σ | 0..* | Identifier | Business Identifier for observation | |||||||||
basedOn | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | Σ | 0..* | Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest) | Fulfills plan, proposal or order | |||||||||
partOf | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | Σ | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | Part of referenced event | |||||||||
status | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required): Codes providing the status of an observation. | ?!SΣ | 1..1 | code | registered | preliminary | final | amended + Binding: ?? (required) | |||||||||
Slices for category | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by pattern:$this Binding: ?? (preferred): Codes for high level observation categories. | S | 1..* | CodeableConcept | Classification of type of observation Slice: Unordered, Open by value:coding.code, value:coding.system Binding: ?? (preferred): Codes for high level observation categories. | |||||||||
code | SΣ | 1..1 | CodeableConcept | Laboratory Test Name Binding: ?? (extensible): Laboratory LOINC Codes | SΣ | 1..1 | CodeableConcept | Body temperature Binding: ?? (extensible): This identifies the vital sign result type. | |||||||||
id | 0..1 | string | Unique id for inter-element referencing |
| |||||||||||||
Slices for extension | 0..* | Extension | Additional content defined by implementations Slice: Unordered, Open by value:url |
| |||||||||||||
Slices for coding | Σ | 0..* | Coding | Code defined by a terminology system Slice: Unordered, Open by value:code, value:system |
| ||||||||||||
text | Σ | 0..1 | string | Plain text representation of the concept |
| ||||||||||||
subject | SΣ | 1..1 | Reference(US Core Patient Profile S | Group | Device | US Core Location Profile) | Who and/or what the observation is about | SΣ | 1..1 | Reference(Patient) | Who and/or what the observation is about | |||||||||
focus | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | Σ | 0..* | Reference(Resource) | What the observation is about, when it is not about the subject of record | |||||||||
encounter | SΣ | 0..1 | Reference(US Core Encounter Profile) | Encounter associated with Observation | Σ | 0..1 | Reference(Encounter) | Healthcare event during which this observation is made |
| ||||||||
effective[x] | SΣC | 0..1 | dateTime S, Period, Timing, instant | Clinically relevant time/time-period for observation us-core-1: Datetime must be at least to day. | SΣC | 1..1 | dateTime, Period | Often just a dateTime for Vital Signs vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day |
| ||||||||
issued | Σ | 0..1 | instant | Date/Time this version was made available | Σ | 0..1 | instant | Date/Time this version was made available | |||||||||
performer | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | Σ | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | Who is responsible for the observation | |||||||||
value[x] | SΣC | 0..1 | Quantity S, CodeableConcept S, string S, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Result Value us-core-3: SHALL use UCUM for coded quantity units. us-core-4: SHOULD use Snomed CT for coded Results | SΣC | 0..1 | Quantity | Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept. Slice: Unordered, Closed by type:$this | |||||||||
dataAbsentReason | SC | 0..1 | CodeableConcept | Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | SC | 0..1 | CodeableConcept | Why the result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | |||||||||
interpretation | S | 0..* | CodeableConcept | Result interpretation Binding: ?? (extensible): Observation Interpretation Codes | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible) |
| |||||||||
note | 0..* | Annotation | Comments about the observation | 0..* | Annotation | Comments about the observation | |||||||||||
bodySite | 0..1 | CodeableConcept | Observed body part Binding: ?? (example): Codes describing anatomical locations. May include laterality. | S | 0..1 | CodeableConcept | Observed body part Binding: ?? (extensible) |
| |||||||||
method | 0..1 | CodeableConcept | How it was done Binding: ?? (example): Methods for simple observations. | 0..1 | CodeableConcept | How it was done Binding: ?? (example): Methods for simple observations. | |||||||||||
specimen | S | 0..1 | Reference(US Core Specimen Profile) | Specimen used for this observation | 0..1 | Reference(Specimen) | Specimen used for this observation |
| |||||||||
device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | 0..1 | Reference(Device | DeviceMetric) | (Measurement) Device | |||||||||||
referenceRange | SC | 0..* | BackboneElement | Result reference range obs-3: Must have at least a low or a high or text us-core-22: SHALL use UCUM for coded quantity units. | C | 0..* | BackboneElement | Provides guide for interpretation obs-3: Must have at least a low or a high or text |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
low | C | 0..1 | ?? | Low Range, if relevant | C | 0..1 | ?? | Low Range, if relevant | |||||||||
high | C | 0..1 | ?? | High Range, if relevant | C | 0..1 | ?? | High Range, if relevant | |||||||||
type | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. | 0..1 | CodeableConcept | Reference range qualifier Binding: ?? (preferred): Code for the meaning of a reference range. | |||||||||||
appliesTo | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. | 0..* | CodeableConcept | Reference range population Binding: ?? (example): Codes identifying the population the reference range applies to. | |||||||||||
age | 0..1 | Range | Applicable age range, if relevant | 0..1 | Range | Applicable age range, if relevant | |||||||||||
text | 0..1 | string | Text based reference range in an observation | 0..1 | string | Text based reference range in an observation | |||||||||||
hasMember | Σ | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | Related resource that belongs to the Observation group | Σ | 0..* | Reference(QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Used when reporting vital signs panel components |
| ||||||||
derivedFrom | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | Related measurements the observation is made from | Σ | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | MolecularSequence | Vital Signs Profile) | Related measurements the observation is made from | |||||||||
component | Σ | 0..* | BackboneElement | Component results | SΣC | 0..* | BackboneElement | Used when reporting systolic and diastolic blood pressure. vs-3: If there is no a value a data absent reason must be present |
| ||||||||
id | 0..1 | string | Unique id for inter-element referencing | 0..1 | string | Unique id for inter-element referencing | |||||||||||
extension | 0..* | Extension | Additional content defined by implementations | 0..* | Extension | Additional content defined by implementations | |||||||||||
modifierExtension | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | ?!Σ | 0..* | Extension | Extensions that cannot be ignored even if unrecognized | |||||||||
code | Σ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: ?? (example): Codes identifying names of simple observations. | SΣ | 1..1 | CodeableConcept | Type of component observation (code / type) Binding: ?? (extensible): This identifies the vital sign result type. |
| ||||||||
value[x] | Σ | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Actual component result | SΣC | 0..1 | Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period | Vital Sign Value recorded with UCUM Binding: ?? (extensible): Common UCUM units for recording Vital Signs. |
| ||||||||
dataAbsentReason | C | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. | SC | 0..1 | CodeableConcept | Why the component result is missing Binding: ?? (extensible): Codes specifying why the result (Observation.value[x]) is missing. |
| ||||||||
interpretation | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | 0..* | CodeableConcept | High, low, normal, etc. Binding: ?? (extensible): Codes identifying interpretations of observations. | |||||||||||
referenceRange | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | 0..* | See referenceRange (Observation) | Provides guide for interpretation of component result | |||||||||||