Vital Signs with Qualifying Elements, published by HL7 International - Clinical Information Modeling Initiative. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cimi-vital-signs/ and changes regularly. See the Directory of published versions
Official URL: http://hl7.org/fhir/us/vitals/ValueSet/respiratoryRateMeasDeviceVS | Version: 2.0.0 | |||
Draft as of 2024-10-09 | Computable Name: RespiratoryRateMeasurementDevicevalueset | |||
Copyright/Legal: This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement |
SELECT SNOMED CT code system values that describe instruments used to measure respiratory rates.
References
Generated Narrative: ValueSet respiratoryRateMeasDeviceVS
This value set includes codes based on the following rules:
http://snomed.info/sct
Code | Display |
717730001 | Impedance pneumography recording/analysis system (physical object) |
334990001 | Peak flow meter (physical object) |
462575001 | Patient monitoring system module, electrocardiographic/respiratory (physical object) |
463005003 | Patient monitoring system module, respiratory (physical object) |
http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem
Code | Display | Definition |
23921000205109 | Respiration strain gauge (physical object) | A device wrapped around a subject chest that measures the number of times a subject's chest expands with each inhalation. This counts the breaths per minute. |
23861000205107 | Capnograph sensor device (physical object) | A device that captures expelled air, either via nasal prongs or CPAP and is used to measure the number of breaths taken per minute. |
Generated Narrative: ValueSet
Expansion based on:
This value set contains 6 concepts
Code | System | Display | Definition |
717730001 | http://snomed.info/sct | Impedance pneumography recording/analysis system (physical object) | |
334990001 | http://snomed.info/sct | Peak flow meter | |
462575001 | http://snomed.info/sct | Patient monitoring system module, electrocardiographic/respiratory | |
463005003 | http://snomed.info/sct | Patient monitoring system module, respiratory | |
23921000205109 | http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem | Respiration strain gauge (physical object) | A device wrapped around a subject chest that measures the number of times a subject's chest expands with each inhalation. This counts the breaths per minute. |
23861000205107 | http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem | Capnograph sensor device (physical object) | A device that captures expelled air, either via nasal prongs or CPAP and is used to measure the number of breaths taken per minute. |
Explanation of the columns that may appear on this page:
Level | A few code lists that FHIR defines are hierarchical - each code is assigned a level. In this scheme, some codes are under other codes, and imply that the code they are under also applies |
System | The source of the definition of the code (when the value set draws in codes defined elsewhere) |
Code | The code (used as the code in the resource instance) |
Display | The display (used in the display element of a Coding). If there is no display, implementers should not simply display the code, but map the concept into their application |
Definition | An explanation of the meaning of the concept |
Comments | Additional notes about how to use the code |