Vital Signs with Qualifying Elements, published by HL7 International - Clinical Information Modeling Initiative. This guide is not an authorized publication; it is the continuous build for version 2.0.0 built by the FHIR (HL7® FHIR® Standard) CI Build. This version is based on the current content of https://github.com/HL7/cimi-vital-signs/ and changes regularly. See the Directory of published versions

: Heart Rate Measurement Method value set - XML Representation

Draft as of 2024-10-09

Raw xml | Download


<ValueSet xmlns="http://hl7.org/fhir">
  <id value="heartRateMeasMethodVS"/>
  <text>
    <status value="extensions"/>
    <div xmlns="http://www.w3.org/1999/xhtml"><p class="res-header-id"><b>Generated Narrative: ValueSet heartRateMeasMethodVS</b></p><a name="heartRateMeasMethodVS"> </a><a name="hcheartRateMeasMethodVS"> </a><a name="heartRateMeasMethodVS-en-US"> </a><p>This value set includes codes based on the following rules:</p><ul><li>Include these codes as defined in <a href="http://www.snomed.org/"><code>http://snomed.info/sct</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td></tr><tr><td><a href="http://snomed.info/id/37931006">37931006</a></td><td>Auscultation (procedure)</td></tr><tr><td><a href="http://snomed.info/id/268447006">268447006</a></td><td>Doppler studies (procedure)</td></tr><tr><td><a href="http://snomed.info/id/29303009">29303009</a></td><td>Electrocardiographic procedure (procedure)</td></tr><tr><td><a href="http://snomed.info/id/13385008">13385008</a></td><td>Mediate auscultation (procedure)</td></tr><tr><td><a href="http://snomed.info/id/264598005">264598005</a></td><td>Oximetry (procedure)</td></tr><tr><td><a href="http://snomed.info/id/113011001">113011001</a></td><td>Palpation (procedure)</td></tr><tr><td><a href="http://snomed.info/id/277917001">277917001</a></td><td>Thoracic impedance cardiography (procedure)</td></tr><tr><td><a href="http://snomed.info/id/239516002">239516002</a></td><td>Monitoring procedure (regime/therapy)</td></tr></table></li><li>Include these codes as defined in <a href="CodeSystem-SolorTemporaryCodeSystem.html"><code>http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem</code></a><table class="none"><tr><td style="white-space:nowrap"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td><a href="CodeSystem-SolorTemporaryCodeSystem.html#SolorTemporaryCodeSystem-641000205104">641000205104</a></td><td>Auscultation - automatic (procedure)</td><td>A procedure that uses a computer aided device to measure blood pressure.</td></tr></table></li></ul></div>
  </text>
  <url value="http://hl7.org/fhir/us/vitals/ValueSet/heartRateMeasMethodVS"/>
  <version value="2.0.0"/>
  <name value="HeartRateMeasurementMethodvalueset"/>
  <title value="Heart Rate Measurement Method value set"/>
  <status value="draft"/>
  <date value="2024-10-09T23:56:46+00:00"/>
  <publisher
             value="HL7 International - Clinical Information Modeling Initiative"/>
  <contact>
    <name
          value="HL7 International - Clinical Information Modeling Initiative"/>
    <telecom>
      <system value="url"/>
      <value value="http://hl7.org/Special/committees/cimi"/>
    </telecom>
  </contact>
  <contact>
    <name value="Logica"/>
    <telecom>
      <system value="url"/>
      <value value="https://www.logicahealth.org/"/>
    </telecom>
  </contact>
  <description
               value="SELECT SNOMED CT code system values that describe how the heart rate was measured."/>
  <jurisdiction>
    <coding>
      <system value="http://unstats.un.org/unsd/methods/m49/m49.htm"/>
      <code value="001"/>
      <display value="World"/>
    </coding>
  </jurisdiction>
  <copyright
             value="This value set includes content from SNOMED CT, which is copyright © 2002+ International Health Terminology Standards Development Organisation (IHTSDO), and distributed by agreement between IHTSDO and HL7. Implementer use of SNOMED CT is not covered by this agreement"/>
  <compose>
    <include>
      <system value="http://snomed.info/sct"/>
      <concept>
        <code value="37931006"/>
        <display value="Auscultation (procedure)"/>
      </concept>
      <concept>
        <code value="268447006"/>
        <display value="Doppler studies (procedure)"/>
      </concept>
      <concept>
        <code value="29303009"/>
        <display value="Electrocardiographic procedure (procedure)"/>
      </concept>
      <concept>
        <code value="13385008"/>
        <display value="Mediate auscultation (procedure)"/>
      </concept>
      <concept>
        <code value="264598005"/>
        <display value="Oximetry (procedure)"/>
      </concept>
      <concept>
        <code value="113011001"/>
        <display value="Palpation (procedure)"/>
      </concept>
      <concept>
        <code value="277917001"/>
        <display value="Thoracic impedance cardiography (procedure)"/>
      </concept>
      <concept>
        <code value="239516002"/>
        <display value="Monitoring procedure (regime/therapy)"/>
      </concept>
    </include>
    <include>
      <system
              value="http://hl7.org/fhir/us/vitals/CodeSystem/SolorTemporaryCodeSystem"/>
      <concept>
        <code value="641000205104"/>
        <display value="Auscultation - automatic (procedure)"/>
      </concept>
    </include>